Products

3M CN-3490 EMI Shielding Tape

    • Product Name: 3M CN-3490 EMI Shielding Tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 510571
    Product Name 3M CN-3490 EMI Shielding Tape
    Manufacturer 3M
    Product Number CN-3490
    Product Type EMI shielding tape
    Backing Material Nickel/copper coated conductive fabric
    Adhesive Type Conductive acrylic adhesive
    Total Thickness 0.11 mm (4.3 mil)
    Width 25.4 mm (1 in)
    Length 32.9 m (36 yd)
    Color Silver/gray
    Surface Resistance 0.05 ohms/square
    Shielding Effectiveness >85 dB (30 MHz to 1 GHz)
    Operating Temperature Range -40°C to 85°C (-40°F to 185°F)
    Core Diameter 76.2 mm (3 in)
    Shelf Life 2 years from date of manufacture

    As an accredited 3M CN-3490 EMI Shielding Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 3M CN-3490 EMI Shielding Tape is packaged as one roll per sealed manufacturer carton, with product label and handling information.
    Container Loading (20′ FCL) 20′ FCL loaded with palletized cartons of 3M CN-3490 EMI Shielding Tape, secured, evenly distributed, and compliant with transport regulations.
    Shipping 3M CN-3490 EMI Shielding Tape is not classified as dangerous goods for transport. Ship in original sealed packaging at ambient temperature, protected from moisture, direct sunlight, and extreme heat. No UN number, hazard class, or special DOT/IATA/IMDG shipping label is required.
    Storage Store 3M CN-3490 EMI Shielding Tape in a cool, dry, well-ventilated area. Keep rolls in original packaging, tightly sealed, away from direct sunlight, heat, moisture, sparks, and open flames. Avoid extreme temperatures and contact with oxidizing agents. Maintain normal room temperature and follow the manufacturer’s SDS and shelf-life recommendations. Do not store near acids, alkalis, or strong oxidizers. Use first-in, first-out rotation.
    Shelf Life Shelf life is 24 months from manufacture when stored in original packaging at 21°C (70°F) and 50% relative humidity.
    Application of 3M CN-3490 EMI Shielding Tape

    Panel Ground Returns in Portable Display Stack-Ups

    In TFT-LCD and OLED module assembly, 3M CN-3490 is die-cut into perimeter strips that bond the display driver IC shield can to the machined stainless-steel mid-frame. The tape carrier is an embossed copper foil of nominal thickness 35 μm; the conductive acrylic adhesive layer adds 23 μm, yielding a compressed bond line thickness below 0.06 mm. The embossed pattern displaces adhesive during lamination and establishes metal-to-metal contact with the substrate at low nip pressure, which is essential for panels with anti-reflective coating margins that cannot tolerate excessive localized force. Ground return paths are terminated at the display bracket before the module enters final assembly, reducing radiated electric-field noise from driver IC switching transients.

    Compliance on consumer display modules is documented under IEC 62368-1:2018 for safety, IEC 61000-4-2:2008 for electrostatic discharge immunity, 2011/65/EU as amended by (EU) 2015/863, and REACH (EC) No 1907/2006. The die-cut web layout typically maintains a part-to-waste matrix ratio of 1:1.7 to prevent liner curl on rotary converting lines. Lamination uses a silicone rubber roller with durometer Shore A 65, nip pressure 0.3 MPa, and traverse speed 0.3 m/s. The pressure-sensitive adhesive reaches handling strength within 1 h at 20–25 °C; full peel strength is verified after 72 h dwell per ASTM D3330/D3330M-04. Terminal products include smartphone OLED modules, tablet LCD backlight units, and notebook display brackets. Published thermal ageing data above 85 °C for this specific configuration is limited; OEM qualification with continuous load at the upper service temperature is required before use in high-brightness panel applications.

    Flexible printed circuit assemblies in foldable handsets use exposed copper grounding pads on the polyimide coverlay opening. 3M CN-3490 is applied after SMT reflow to bond the FPC tail to the shield frame, eliminating a solder step that can induce tin whisker growth on fine-pitch pads and thermomechanical stress at the polyimide-adhesive interface. The conductive acrylic adhesive is formulated to penetrate light oxide layers on electroless nickel immersion gold pads, where the nickel layer is maintained at 3–5 μm and the gold flash at 0.05–0.1 μm. Tape width is specified at 1.2:1 relative to the exposed copper pad width; overlaps below this ratio exhibit higher peel initiation at dynamic folding cyclic loads. Die-cut parts are placed by vacuum pick-and-place, liner removal is performed at a 180° peel angle with a peel speed below 0.3 m/s, and lamination pressure is controlled between 0.2 MPa and 0.4 MPa for 2–5 s. Initial contact resistance is tested per MIL-STD-202G Method 307 and must remain at or below 0.1 Ω; after 250 000 flex cycles on a 1.0 mm radius fixture, the upper acceptance limit is 0.3 Ω, though published data for CN-3490 on dynamic flex-on-glass is limited. Compliance falls under IPC-A-610J Class 3 and IPC-6013D Class 3 for flexible circuit acceptability. Terminal products include foldable OLED smartphones, tablet display hinges, and smartwatch flex-to-mainboard grounding straps.

    What Grounding Defect Mode Dominates in 5G mmWave RF Modules?

    In antenna-in-package modules for 26 GHz and 28 GHz bands, the dominant grounding defect mode is not bulk open-circuit failure but intermittent high-frequency ground return caused by oxide film formation on cast aluminium shield frames. CN-3490 is used between the FPC ground tab and the shield-can sidewall; the embossed copper carrier provides low-inductance contact across multiple small contact points. At mmWave frequencies, a continuous ground reference is required because quarter-wave resonances on the module PCB can shift with incomplete shield contact. Production qualification requires surface mount reflow to be completed before tape application; the conductive acrylic adhesive is not rated for peak reflow exposure above 260 °C.

    Compliance for RF modules follows FCC 47 CFR Part 15 Subpart B, RSS-Gen Issue 5, and ETSI EN 301 489-1 for receiver and transmitter electromagnetic compatibility. The die-cut geometry maintains a ground-tab-to-tape width ratio of 1:1.5, providing 0.5 mm minimum edge overlap. Lamination is performed with a flat polyurethane pad durometer Shore A 70 at 0.25 MPa for 3 s. The assembly is then subjected to 85 °C / 85% RH damp-heat storage for 500 h, followed by a contact resistance check; pass criterion is ≤0.2 Ω, measured with a four-wire milliohmmeter at 100 mA test current. Terminal products include 5G smartphones, fixed wireless access customer premises equipment, and base station remote radio unit shield-ground tabs. In high-vibration outdoor CPE installations, additional mechanical retention is required if the tape bond is the sole ground connection; the adhesive alone is not considered a load-bearing joint.

    Application ZoneGoverning StandardCritical Test ParameterProduction Acceptance Limit
    Display panel ground returnIEC 61000-4-2:2008Contact discharge to metal frame±4 kV no module upset
    FPC shield terminationMIL-STD-202G Method 307Initial contact resistance≤0.1 Ω
    5G mmWave module grounding85 °C / 85% RH damp heatContact resistance after 500 h≤0.2 Ω
    Automotive ADAS seam shieldingCISPR 25:2021Radiated emissions 150 kHz–2.5 GHzClass 3 limits
    IVD analyzer partition groundingCISPR 11:2015Radiated disturbance 30 MHz–1 GHzGroup 1 Class A

    On automotive ADAS camera modules, the aluminium die-cast front housing and PCB shield frame require a conformable EMI closure strip that can survive thermal shock and body-mounted vibration loads. CN-3490 is cut into narrow strips and applied along the housing seam before final screw insertion. The tape bond retains shielding continuity under micro-displacement of the housing joint, which is a common root cause of intermittent radiated emission failures in vehicle-level validation. The compressed bond line thickness after assembly is 0.045 mm, approximately 75% of the original 0.06 mm total tape thickness. Overlap width at the seam is set at 2.0 mm minimum; corners are folded with a 1.5 mm radius to prevent foil fracture during housing screw torque sequence of 0.3 N·m initial and 0.6 N·m final. Compliance is evaluated under CISPR 25:2021 for radiated emissions, ISO 11452-4:2020 for bulk current injection immunity, and AEC-Q100 Grade 2 for component temperature requirements. The tape should not be exposed to engine-compartment temperatures exceeding 105 °C continuous without supplier validated data; published data for this specific application is limited. Terminal products include forward-facing monocular camera housings, surround-view camera modules, and roof-mounted telematics antenna pods.

    Screening Effectiveness Under IEC 60601-1-2 Immunity Requirements in In Vitro Diagnostic Instruments

    In chemiluminescence immunoassay analyzers and hematology analyzers, photomultiplier tube and high-gain photodiode front ends are mounted inside partitioned metal enclosures. CN-3490 is used to bond copper shielding partitions to the chassis and to close service access seams that cannot use conductive gaskets due to particulate shedding limits. The tape is applied after the shield compartments are installed; joints are lapped by 5 mm minimum, and unbonded gaps between ground paths must not exceed 3 mm to avoid slot-antenna effects in the 30–1000 MHz range specified by CISPR 11:2015 Group 1 Class A. Surface preparation uses a lint-free polyester wipe saturated with 2-propanol, followed by 30 s air drying before adhesive placement. Lamination is performed with a static-dissipative roller having surface resistivity between 1×10^6 Ω/sq and 1×10^9 Ω/sq, at a pressure of 0.3 MPa. Compliance is assessed under IEC 60601-1-2:2014, IEC 61010-1:2010, and 2011/65/EU. The conductive adhesive is not evaluated for patient skin contact under ISO 10993-1:2018; use is restricted to internal compartments and service panels. Terminal products include automated immunoassay analyzers, hematology cell counters, and molecular diagnostic nucleic acid extraction modules.

    When Board-Level Shield Clips Are Replaced by Die-Cut Foil Tape in Edge-Compute Modules

    Industrial edge-compute gateways and vision controllers frequently replace stamped shield clips with die-cut CN-3490 tape to reduce total assembly height by 0.8 mm and remove the PCB keep-out zone associated with clip retention features. The tape is laminated directly over the milled aluminium top cover and the exposed ground ring on the PCB. This design is valid only where the shield cover is removable and the tape is re-applied after each service event. The die-cut layout uses a 1.5 mm web between rectangular parts; the tape-to-ground-ring width ratio is held at 1.05:1 to prevent bridging to adjacent signal traces on high-density rigid-flex boards. Lamination uses a flat silicone rubber block at 0.25 MPa for 3 s, followed by a 1 h wait before bond-resistance test. Compliance is verified under MIL-STD-461G for radiated emissions and IEC 61000-6-4:2018 for industrial emissions; electrical bonding continuity may also be checked against EN 61000-4-4:2012 fast transient immunity. Terminal products include modular machine vision controllers, industrial IoT gateways, and robotics servo drive enclosures. Published data for repeated service cycles exceeding 20 re-applications on the same substrate is limited; OEM validation should measure peel adhesion loss per ASTM D3330/D3330M-04 after each service interval.

    Free Quote

    Competitive 3M CN-3490 EMI Shielding Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The 3M CN-3490 EMI shielding tape is constructed from a nickel–copper-plated woven ripstop fabric carrier coated with a conductive pressure-sensitive acrylic adhesive. The carrier is a textile rather than a solid metal foil, which determines the product’s mechanical and shielding behavior. Nominal total thickness is 0.12 mm, and the product is supplied as slit rolls with a release liner, commonly in widths from 25 mm to 100 mm depending on converter stock. Published datasheet values commonly report surface resistivity below 0.05 Ω/sq when measured according to ASTM D257, and plane-wave shielding effectiveness from 70 dB to 85 dB over 30 MHz to 1 GHz under ASTM D4935-18. The adhesive is acrylic and electrically conductive in the z-axis, but it is not a structural adhesive and does not replace mechanical fasteners. The tape is intended for enclosure seam shielding, cable shield grounding, and low-profile bonding of conductive fabric segments.

    CN-3490 is rated for continuous service from −40 °C to 105 °C. The minimum practical application temperature is approximately 16 °C, below which the acrylic pressure-sensitive adhesive does not wet polycarbonate or powder-coated steel reliably. Storage should be maintained at 18 °C to 27 °C and 40 % to 50 % relative humidity; shelf life is approximately 12 months from manufacture. A qualification lot should be tested for peel adhesion to the actual substrate per ASTM D3330/3330M, because the stainless steel values used in datasheets do not predict adhesion to low-surface-energy plastics. The woven fabric is tear-resistant but can be cut intentionally with a rotary die; unintended nicks in the backing create exposed metal filaments and possible loose conductive particles.

    What limits CN-3490 as a magnetic-field barrier below 10 MHz?

    At frequencies below approximately 10 MHz, a thin conductive fabric tape cannot provide high magnetic shielding. The shield operates mainly by reflection of the electric field and plane-wave components, while absorption in a thin metal layer is weak. The skin depth in copper at 100 kHz is approximately 206 µm, but the plated metal thickness on a fabric carrier is in the micrometer range. Consequently, magnetic near-fields between 50 kHz and 1 MHz pass around or through the tape with little attenuation. Published CN-3490-specific magnetic-field shielding data is limited; qualification should be performed with loop antennas under CISPR 16-1-1 or MIL-STD-461 RE101 procedures rather than by extrapolating a far-field ASTM D4935 value.

    The ASTM D4935-18 coaxial fixture uses a 133 mm annular sample and a 50 Ω measurement path. It does not capture enclosure seam leakage, overlap resistance, or the effect of adhesive voiding along a curved seam. Installed shielding may therefore be 10 dB to 30 dB below coupon-level measurements if the tape is not lapped and wetted continuously. This gap is known from seam attenuation tests; the exact reduction depends on aperture length, tape width, and substrate flatness.

    Radio-frequency current on a shielding tape flows primarily on the outermost surface. At 1 GHz, the skin depth of copper is approximately 2.1 µm; a thin nickel–copper plating is therefore sufficient for high-frequency surface conduction. At 100 kHz, however, the skin depth is about 206 µm, which explains why the micrometer-range plating on a fabric carrier cannot support the eddy currents needed for magnetic shielding. The adhesive layer contributes a separate conduction path: z-axis particle loading gives low through-plane resistance, but in-plane resistance through the adhesive is much higher than through the plated fabric. Overlap joints therefore depend on adhesive wet-out and on the direct fiber-to-substrate contact promoted by roll pressure.

    On a production line, CN-3490 is applied after the substrate is cleaned with 70 % isopropanol or the solvent system specified in the assembly procedure. A pH-neutral aqueous cleaner may leave alkaline residue that retards adhesion. The tape should be laminated with a pneumatic silicone rubber nip-roller at 3 N/mm² to 5 N/mm², and feed speed should be held between 0.05 m/s and 0.15 m/s to avoid entraining air. For enclosure flanges with a radius of curvature below 20 mm, a hand roller with a narrow contact edge is used after the main laydown. The release liner is removed at a low peel angle to avoid lifting the adhesive from the backing. Surface energy of the substrate should exceed 38 mN/m by ASTM D2578; if not, corona or plasma treatment is required before lamination.

    Contact resistance in a lapped seam is controlled by the conductive adhesive and the physical fiber-to-fiber contact at the tape surface. A single-layer flat sample may show low surface resistivity, but a two-layer overlap on a painted or anodized substrate can show higher resistance because the adhesive cannot displace thick oxide layers. For aluminum substrates, chromate conversion coating or an appropriate conductive primer is usually required. For steel with zinc plating, the surface must be cleaned with a non-alkaline solvent and dried before lamination. The acrylic adhesive develops strength over time; measurements made immediately after lamination may be below the 24 h value. Peel and contact resistance should be re-measured after a dwell period of 24 h at 23 °C and 50 % RH.

    When foil-backed shielding tapes crack and CN-3490 remains viable

    Copper foil tape may be selected when enclosure seams are flat and the objective is the highest possible plane-wave attenuation. However, foil work-hardens when it is bent around radii below approximately 3 mm or when it is applied over repeatedly flexing cable shields. Those conditions produce microcracks that increase DC resistance and degrade shielding after thermal cycling. CN-3490 distributes bending strain through its woven carrier and is therefore less prone to conductor fracture. The outer nickel surface also maintains lower contact resistance in indoor environments than bare copper foil that has not been passivated. In contrast, unsupported conductive transfer tape can be thinner and die-cut into narrower features, but it tears during liner removal and does not bridge gaps. CN-3490 bridges a 0.5 mm to 1.0 mm seam gap under light pressure; bridged areas should not be used across moving joints because the adhesive may creep and the backing may flap.

    Another distinction involves corrosion compatibility. Copper foil tape can develop cuprous and cupric oxide films at elevated humidity; the nickel–copper plating on CN-3490 is more stable in indoor electronics. However, if CN-3490 is placed in direct contact with magnesium, zinc-plated steel, or bare aluminum in a marine environment, galvanic corrosion can occur. Qualification in such conditions should follow IEC 60068-2-52 or ASTM B117, with contact resistance measured before and after exposure. Published CN-3490-specific salt-spray performance is limited, so the product should not be approved for outdoor sealed enclosures without environmental testing.

    The tape does not provide compressible environmental sealing. A fabric-over-foam gasket can accommodate dynamic gaps between 0.5 mm and 2.0 mm and maintain contact force after vibration; CN-3490 is a permanent adhesive bond. Rework is difficult and may leave conductive residue on the housing. If the joint is opened repeatedly, spring-finger contacts or conductive elastomers are more suitable. CN-3490 is therefore selected for permanent seams or for applications where low installed height is more important than repeated openability.

    In high-volume conversion, the roll must be slit with minimal edge damage. During kiss-cutting on a flatbed plotter, liner penetration of 30 µm to 50 µm is common; deeper penetration cuts the woven backing and produces loose metal-coated fibers. Loose fibers can move into PCBA clearances and create short-circuit paths. The slitting room should use static-dissipative work surfaces and filtered air extraction. If the tape is wound under high tension, the roll telescopes during storage and loses edge alignment. These are known conversion issues for conductive fabric tapes and are not unique to CN-3490.

    Comparative selection attributes and standards referenced during qualification

    The following methods are used during incoming inspection or substitution evaluations. The table is a compliance matrix, not a performance claim.

    Test or compliance requirementReferenceMeasurement note
    Plane-wave shielding effectivenessASTM D4935-18Report 30 MHz to 1 GHz coupon attenuation; do not use as installed seam value
    Peel adhesion to stainless steelASTM D3330/3330MMeasure after 20 min dwell; clean substrate with specified solvent
    Surface resistivityASTM D257Use guarded electrode; precondition at 23 °C and 50 % RH
    Flame resistanceUL 510Confirm recognition for the specific tape width and substrate
    Thermal cyclingIEC 60068-2-14 Test NbMonitor adhesion and contact resistance after 100 cycles
    RoHSEU 2011/65/EUObtain current supplier declaration for specific lot

    The acrylic adhesive is sensitive to ketone-based solvents, toluene, and chlorinated cleaners. These chemicals can soften the adhesive and reduce peel strength before any visual degradation occurs. Avoid applying the tape over surfaces coated with amine-containing curing agents because amine residues can inhibit the adhesive. The maximum service temperature is 105 °C, so CN-3490 is not rated for reflow soldering or powder-coat oven cycles. When the tape must survive a powder-coat oven at 180 °C, a different shielding material with a silicone adhesive or a mechanically fastened gasket is required.

    A representative production case is grounding a metallized fabric cable shield to a connector backshell. The tape is cut to length and wrapped around the assembly with a 10 mm overlap. The surface must be free of mold-release agents; if mold release is present, the first step is a 70 % isopropanol wipe followed by a 30 s flash. After wrapping, a 2 bar silicone roller compresses the tape, and a stainless-steel band clamp provides mechanical strain relief. The adhesive by itself will not maintain a stable bond under repeated cable flexure, so the clamp or ferrule is required. First-article qualification should include contact resistance measured through the overlapped joint after 500 flex cycles and shielding effectiveness measured with the connector fully assembled. Published data for this specific configuration is limited, so production approval should rely on measured values from the actual harness.

    Top