| HS Code | 961192 |
| Productname | 3M 439 Premium Performance Aluminum Foil Tape |
| Manufacturer | 3M |
| Model | 439 |
| Backingmaterial | Dead soft aluminum foil |
| Adhesivetype | Acrylic |
| Totalthickness | 4.0 mil (0.10 mm) |
| Backingthickness | 2.0 mil (0.05 mm) |
| Adhesivethickness | 2.0 mil (0.05 mm) |
| Adhesiontosteel | 60 oz/in (66 N/100 mm) |
| Tensilestrength | 25 lb/in (438 N/100 mm) |
| Elongationatbreak | 5% |
| Operatingtemperaturerange | -20°F to 250°F (-29°C to 121°C) |
| Watervaportransmission | 0.05 g/100 sq in/24 hr |
| Flamespreadindex | 0 |
| Smokedevelopedindex | 0 |
| Reflectivity | 95% |
| Standardlength | 50 yd (45.7 m) |
| Standardwidth | 2 in (50.8 mm) |
| Corediameter | 3 in (76.2 mm) |
As an accredited 3M 439 Premium Performance Aluminum Foil Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in a case of 24 rolls; each 2 in x 60 yd roll is individually wrapped and labeled. Quantity: 24 rolls. |
| Container Loading (20′ FCL) | 3M 439 Premium Performance Aluminum Foil Tape loaded in 20′ FCL, palletized, shrink-wrapped, secured in dry container for ocean freight. |
| Shipping | 3M 439 Premium Performance Aluminum Foil Tape is not classified as dangerous goods. It ships as non-hazardous general freight with no UN number, hazard class, or packing group. Store in a cool, dry area away from direct sunlight and extreme temperatures, using original packaging to prevent damage. |
| Storage | Store 3M 439 Aluminum Foil Tape in a cool, dry, well-ventilated area, away from heat, sparks, open flames, and direct sunlight. Keep rolls in original sealed packaging, protected from moisture, dust, and physical damage. Recommended conditions: 16–27°C (60–80°F) and 40–60% relative humidity. Do not freeze. Keep away from strong oxidizers. Rotate stock, using oldest first. Use within recommended shelf life. |
| Shelf Life | Shelf life: 18 months from date of manufacture when stored in original packaging at 60–80°F (16–27°C) and 40–60% relative humidity. |
On aluminum airframe skins prepared for refinish, 3M 439 Premium Performance Aluminum Foil Tape is applied after a solvent wipe using 70% isopropanol / 30% deionized water and a continuous water-break check under ASTM F22-21. Application is restricted to metal surface temperatures between 15°C and 35°C, relative humidity below 75%, and a dew point at least 5°C below the surface temperature. The tape is positioned without stretching. A 60 Shore A rubber roller loaded to 40–50 N is passed at 0.1 m/s. Adjacent strips overlap 10–15 mm. No wet mixing ratio is used because the acrylic pressure-sensitive adhesive is factory coated. During polyurethane topcoat cure at 82°C for 60–90 min, the foil backing blocks paint strike-in at seams and rivet heads. Removal is performed only after the surface has cooled below 40°C, at a peel angle of 45° and a rate below 150 mm/s. Incoming lots are verified by ASTM D3330/D3330M-24, Test Method A, against stainless steel. The manufacturer-listed continuous service ceiling of the acrylic adhesive is 121°C. Sustained exposure above that threshold produces cohesive splitting and adhesive ghosting. Tape strips stretched more than 5% during application recover during the bake and generate edge lift. Adhesive residue after cure is assessed at 10× magnification on 2024-T3 clad surfaces. Residue-free removal is the acceptance condition.
Masking of body seams and sensor apertures in a refinish booth precedes waterborne basecoat and two-component clearcoat application. The foil tape is placed without stretch, and on curved bumper surfaces it is laid in 5–10 mm incremental arcs with 3 mm overlap. Booth conditions are held at 18–25°C and 50–60% relative humidity. Basecoat flash-off runs for 10 min at 23°C and 50% relative humidity before clearcoat bake. The clearcoat cure window is 20–30 min at 121°C. Oven hot spots above 135°C cause acrylic softening and must be corrected with thermocouple verification before production. After bake, the surface is cooled below 40°C. The tape is then lifted at 90–135° to the surface and below 150 mm/s. Peeling at temperatures above 50°C transfers adhesive to fresh clearcoat. Paint systems containing more than 5% aromatic hydrocarbon solvent may attack the adhesive edge. Contact time with such solvents is kept under 2 h. Final adhesion on painted steel is confirmed by ASTM D3330/D3330M-24. The foil tape also masks wheel arch flanges and door aperture seams without leaving fibrous edges. Because no liquid primer is used, there is no mixing ratio. The terminal finished surface is a two-layer basecoat/clearcoat automotive finish with masked body openings free of overspray and adhesive residue.
At substrate temperatures below 5°C, the acrylic pressure-sensitive adhesive does not wet out foil-scrim-kraft facing sufficiently to reach final peel strength measured by ASTM D3330/D3330M-24. Condensation on the foil-facing layer creates a water interlayer that prevents bond formation. The tape must not be applied when the surface is below 5°C or within 3°C of the dew point. For installation in cold mechanical rooms, electric forced air is used to pre-warm the seam to 15°C before tape placement. Transverse seams are sealed with 50 mm overlap. Flanged duct joints are sealed with 75 mm overlap. A stainless steel roller 50 mm wide is loaded to 40–60 N and moved at 0.1 m/s. Final adhesion develops after 24 h at 21°C and 50% relative humidity. If the duct is pressurized to 250 Pa before full dwell, edge lift may occur at transverse seams. Surface burning acceptance is tied to ASTM E84-25 and UL 723. Duct construction follows SMACNA HVAC Duct Construction Standards, 4th edition. The tape is not a substitute for mechanical fastening at flanged joints. No mixing ratio applies to the tape. The terminal finished product is an air-distribution duct with foil-faced insulation joined at seams and rated under the building code for surface burning characteristics.
| Standard or Regulation | Function | Acceptance Condition |
|---|---|---|
| ASTM D3330/D3330M-24 | Peel adhesion of pressure-sensitive tape | Manufacturer lot certificate required |
| ASTM D3652/D3652M-24 | Tape thickness verification | Within manufacturer tolerance |
| ASTM D3759/D3759M-24 | Breaking strength and elongation of backing | No tear at 50 mm overlap |
| ASTM E84-25 / UL 723 | Surface burning characteristics | Building code classification required |
| REACH (EC) No 1907/2006, Article 33 | SVHC communication | EU importer declaration requested |
| RoHS Directive 2011/65/EU, Annex II | Restricted substances | Manufacturer compliance certificate |
Refrigerator liner ports are sealed before polyurethane foam injection at 20–25°C. The tape patches cover 10–20 mm circular foam injection ports with 50 mm × 50 mm squares. Roller pressure is 30 N over the liner flange. ABS and HIPS liner surfaces must be free of siloxane mold release. Cleaning is done with 50% isopropanol / 50% deionized water. If siloxane residue remains, the tape delaminates during foam rise. Polyurethane foam exotherm reaches 40–60°C for 10–15 min. The tape holds the port seal during that exotherm without blocking foam expansion into the adjacent cavity. Port edges are inspected after foam cure for adhesive wash-back. The finished appliance cabinet contains fully sealed insulation ports. No liquid adhesive mixing ratio is used. IEC 60335-1, Clause 30.2, is referenced for insulation material fire safety, but the tape is not the primary insulation material. Published data for this specific foam-port configuration is limited. Qualification on production liners is required before line release.
Clean bright aluminum foil has a surface emittance near 0.03–0.05 measured under ASTM C1371. After die-cutting, exposed fibrous edges and dust layers raise local emittance. The foil tape is used to seam cut edges and restore a low-emittance surface in enclosure liners. It is applied at 20–28°C with 25 mm overlap over the seam. Roller pressure is 30–50 N. Wrinkles must be avoided because an air gap between foil and substrate increases radiative heat transfer. The tape backing itself retains low surface emittance only if free of finger oil and dust. Dry wiping is preferred. Oil-based cleaning agents raise emittance and must be avoided. Continuous service is limited to 121°C. The terminal assembly is a lined enclosure with reduced radiative coupling across seams. No mixing ratio is introduced. This configuration is used in power electronics enclosures and test chambers where thermal radiation across interior surfaces must be controlled.
In marine engine bays, foil-faced acoustic insulation is sealed against diesel mist and salt spray. The tape is applied with 25 mm overlap and 50 N roller pressure. The substrate must be dry. Water trapped beneath the tape raises local pH and initiates aluminum corrosion. Continuous contact with alkaline washdown cleaners at pH above 9 degrades the foil backing. Direct contact with copper alloy piping is not permitted because the galvanic potential difference accelerates aluminum corrosion in moist chloride conditions. Qualification for salt fog exposure uses ASTM B117-19. Published data for extended salt spray on this specific engine-bay substrate is limited. The supplier test report should be requested for exposures exceeding 500 h. The tape is not rated for continuous immersion or for direct contact with exhaust surfaces above 121°C. No mixing ratio applies. The finished engine bay contains secured acoustic insulation panels with sealed foil edges that resist minor splash exposure but not continuous wetting.
Competitive 3M 439 Premium Performance Aluminum Foil Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
3M 439 Premium Performance Aluminum Foil Tape is manufactured as a dead-soft aluminum foil backing coated with a pressure-sensitive acrylic adhesive. The backing thickness is nominally 0.076 mm (3.0 mil), and the adhesive layer is approximately 0.051 mm (2.0 mil), producing a total thickness of 0.13 mm (5.0 mil). The product is self-wound without a liner and is supplied in slit widths from 48 mm to 1219 mm. Common hand-roll formats include 48 mm × 45.7 m, 72 mm × 45.7 m, and 96 mm × 45.7 m. The foil backside is treated to provide controlled unwind in manual and automated dispensers.
The tape is used for sealing joints, seams, and foil facings in HVAC ductwork, for lamination of aluminum-faced mineral wool and glass fibre insulation, and for temporary metal repair during powder coating or paint masking. It is not a structural load-bearing repair system.
| Property | Nominal value | Test method |
|---|---|---|
| Backing thickness | 0.076 mm (3.0 mil) | ASTM D3652/D3652M |
| Total thickness | 0.13 mm (5.0 mil) | ASTM D3652/D3652M |
| Adhesion to stainless steel, 180° peel | 24.6 N/25 mm (90 oz/in) | ASTM D3330/D3330M Test A |
| Tensile strength, machine direction | 131 N/25 mm (30 lb/in) | ASTM D3759/D3759M |
| Elongation at break, machine direction | 6 % | ASTM D3759/D3759M |
| Service temperature, continuous | −40 °C to 121 °C (−40 °F to 250 °F) | Manufacturer thermal stability data |
| Service temperature, intermittent | 149 °C (300 °F) | Manufacturer thermal stability data |
Commodity aluminum foil tapes frequently use a hard-temper backing and a solvent-borne rubber-resin adhesive. The 439 adhesive is an acrylic pressure-sensitive system that offers higher shear strength and improved aging resistance than many rubber-resin systems, although initial tack to low-surface-energy plastics can be lower. The backing difference is also significant: dead-soft aluminum conforms to irregular seams without fracturing, while hard-temper foil can crack at folds or during vibration. The values above are manufacturer-published typical values; lot-specific certificates should be requested for critical process validation.
Storage conditions affect unwind performance and adhesive transfer. Manufacturer documentation recommends storage at 4 °C to 32 °C and 40–60 % RH. Shelf life is typically 24 months from date of manufacture when stored in original packaging. Rolls should be allowed to reach application temperature before use to prevent condensation at the tape-substrate interface.
Long-duration shear performance in HVAC ducts is controlled by the crosslinked acrylic network rather than by tackifying-resin mobility. Rubber-resin systems can soften at 70 °C and lose shear strength as low-molecular-weight tackifiers migrate. Acrylic systems exhibit higher cohesive strength at elevated temperatures and resist plasticiser migration from flexible PVC and foam facings. Accelerated aging at 70 °C and 85 % RH typically produces less than 15 % peel loss on galvanised steel, whereas rubber-resin tapes may show 30–40 % loss under the same conditions. The 439 tape is rated for continuous service from −40 °C to 121 °C and for intermittent exposure up to 149 °C. At −40 °C, the backing does not embrittle and the adhesive remains flexible. Application at 4 °C or below is not recommended because moisture condensation at the interface can produce immediate bond failure.
Static shear resistance should be evaluated according to ASTM D3654/D3654M when the tape is used in vertically oriented seams or under continuous load. Published lot-specific data can be requested from the manufacturer. In automated converting and insulation lamination lines, the self-wound roll is unwound under controlled tension. Start-up tension should remain below 15 N/25 mm width to avoid permanent elongation of the dead-soft backing.
| Feature | 3M 439 | Rubber-resin foil tape | Silicone adhesive foil tape |
|---|---|---|---|
| Adhesive chemistry | Acrylic | Rubber/resin | Silicone |
| Continuous service temperature | −40 °C to 121 °C | −20 °C to 70 °C typical | −40 °C to 260 °C typical |
| Room-temperature peel on steel | 24.6 N/25 mm | High initial tack to low-energy surfaces | Lower peel on steel |
| Backing conformability | Dead-soft aluminum | Often hard-temper aluminum | Varies by construction |
| Surface burning classification | UL 723 Class 1 where listed | Often not listed | Often not listed |
| Plasticiser migration resistance | High | Lower | High but with lower room-temperature tack |
In rectangular galvanised steel duct fabrication, 439 is applied over flanged transverse joints and longitudinal seams after the metal has been wiped with 70 % isopropanol / 30 % water or a compatible solvent cleaner. The dead-soft backing permits the tape to be burnished into the seam with a hard-rubber or plastic applicator. Incomplete burnishing leaves low-pressure areas under the adhesive and is a frequent cause of edge lift on production lines. For insulated ducts, the tape seals aluminum foil facings and prevents moisture ingress at cut edges. The aluminum foil backing provides a barrier when the tape is fully bonded and seam edges are burnished, although published moisture vapour transmission data for this specific configuration is limited.
For duct leakage testing, taped joints in low-pressure systems are commonly tested at 500 Pa (2 in w.g.) according to the SMACNA HVAC Air Duct Leakage Test Manual. Published 439-specific leakage rates are limited; field testing on the actual duct substrate is required because joint geometry, surface cleanliness, and application pressure affect the result. High-pressure duct construction may require mechanical fastening in addition to tape.
Surface burning characteristics are evaluated under UL 723 / ASTM E84. Class A/Class 1 interior finish performance requires flame-spread index ≤ 25 and smoke-developed index ≤ 450. Manufacturer documentation lists 439 for applications where UL 723 Class 1 surface burning classification is required. The listing may vary by roll configuration and production site; the current listing certificate should be reviewed before specification. Compliance with EU 2011/65/EU and Regulation (EC) 1907/2006 is documented in manufacturer certification for standard production, but no direct food-contact or potable-water listing is implied.
In mineral wool pipe insulation and glass fibre board lamination, the backing must follow curvature and remain bonded during thermal expansion and vibration. Hard-temper aluminum foil tapes can develop microcracks at bends, creating leak paths through the facing. The 439 backing is a dead-soft aluminum with elongation at break of 6 % and tensile strength of 131 N/25 mm. These characteristics allow the tape to conform to bends without fracturing and to hold longitudinal seams in high-vibration industrial HVAC service. The backing is not a structural member and should not be used to carry load or bridge gaps wider than 3 mm.
On production-scale lamination lines, the tape is applied over cut edges and butt joints. A nip roller with 60–80 Shore A hardness and line pressure of 0.3–0.6 N/mm² is typical for pressure-sensitive aluminum tapes. At 22 °C, dwell time before trim cutting should be at least 5 s to allow pressure-sensitive bond formation. At lower temperatures, this dwell time increases. Field observations from insulation finishing lines indicate that hard-temper foil tapes show more edge lift when panels expand and contract, while the dead-soft backing maintains seam conformity.
Relative to silicone-adhesive foil tapes, 439 has lower continuous-temperature resistance but higher room-temperature peel and better paint and adhesive compatibility. Relative to conductive copper tapes, 439 is not an EMI/RFI tape; the aluminum backing provides some shielding, but the acrylic adhesive is not conductive and through-thickness resistance is not controlled. Relative to commodity rubber-resin foil tapes, 439 has better elevated-temperature shear and lower odour and outgassing in indoor HVAC service.
Operational boundaries: 439 is not recommended for continuous immersion in water, aliphatic hydrocarbons, chlorinated solvents, strong acids, or strong bases. It should not be used on surfaces with silicone-based release agents, amine-based corrosion inhibitors, or loose oxide scale. For exterior exposure, long-term UV and moisture resistance is limited; the tape should be covered by a mechanical cladding or sealed at edges. Application below 0 °C or above 49 °C substrate temperature is outside the recommended process window. Bond strength develops over time; at 22 °C, full adhesion to galvanised steel is typically reached within 24 h. Critical applications should validate adhesion using field peel tests on the actual substrate under production conditions.