Products

3M 399FR Flame Retardant Glass Cloth Tape

    • Product Name: 3M 399FR Flame Retardant Glass Cloth Tape
    • Factroy Site: Yinchuan, Ningxia, China
    • Price Inquiry: sales8@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 224274
    Brand 3M
    Productnumber 399FR
    Productname 3M 399FR Flame Retardant Glass Cloth Tape
    Producttype Flame retardant glass cloth tape
    Backingmaterial Glass cloth
    Adhesivetype Silicone
    Color White
    Totalthickness 7.5 mil (0.19 mm)
    Temperaturerange -40°F to 400°F (-40°C to 204°C)
    Tensilestrength 100 lb/in (175 N/10 mm)
    Adhesiontosteel 35 oz/in (3.8 N/10 mm)
    Dielectricstrength 600 V/mil (24 kV/mm)
    Elongationatbreak 5%
    Flameretardant Yes
    Rolllength 36 yd (33 m)
    Corediameter 3 in (76.2 mm)
    Widthoptions 1/2 in, 3/4 in, 1 in, 1-1/2 in, 2 in
    Standards UL 510, MIL-I-19166C

    As an accredited 3M 399FR Flame Retardant Glass Cloth Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing One roll of 3M 399FR Flame Retardant Glass Cloth Tape per carton, twenty rolls per case, individually wrapped and labeled.
    Container Loading (20′ FCL) 20′ FCL loaded with palletized cartons of 3M 399FR Flame Retardant Glass Cloth Tape, safely secured and documented for export.
    Shipping 3M 399FR Flame Retardant Glass Cloth Tape is not regulated as a hazardous material for transportation by DOT, IATA, IMDG, or ADR. Ship in original packaging, keep dry, and protect from excessive heat or damage. No UN number, hazard class, packing group, labels, or placards are required.
    Storage Store in a cool, dry, well-ventilated area away from direct sunlight, heat, sparks, flames, and oxidizing agents. Keep unused tape in its original packaging, tightly closed, at 16–27°C (60–80°F) and 40–60% relative humidity. Protect from moisture, dust, and physical damage. Rotate stock, use oldest first, and follow manufacturer shelf-life guidance. Do not store near food. Keep away from incompatible materials.
    Shelf Life Shelf life is typically 12 months from manufacture when stored in original packaging at 21°C (70°F) and 50% relative humidity.
    Application of 3M 399FR Flame Retardant Glass Cloth Tape

    In low-voltage switchgear, busbar joints and cable lug transitions are overwrapped after torque verification and contact resistance checks. The 3M 399FR tape is applied with a 50% overlap in a single spiral pass from the heat-shrink boot edge to the lug barrel. Surface preparation uses a 70:30 isopropanol-to-deionised water wipe; the surface is dried until no solvent film is visible. Wrapping tension is held below the point at which glass weave distortion begins, a value established on a semi-automatic tape head using a calibrated tensiometer. Because the silicone pressure-sensitive adhesive builds peel strength over 24 h at 23 °C, the busbar joint should not be hi-pot tested immediately unless a dwell protocol has been qualified. The wrapped joint can be used as mechanical protection for shrink sleeve terminations, not as the sole primary insulation unless creepage and clearance distances meet IEC 60664-1. Voltage withstand after wrapping is commonly verified at 1000 V plus twice the rated voltage for 60 s; acceptance is no breakdown or flashover. Published data for this specific configuration is limited, so the test voltage and dwell time must be taken from the final equipment standard rather than from tape product literature.

    Application conditionTest method or standard codeData used for acceptance
    Vertical flame propagation on wire bundle assembly14 CFR 25.853(a), Appendix F Part IBurn length after 60 s exposure, flame time after removal, drip extinguish time
    Dielectric breakdown of tape constructionASTM D1000-17Breakdown voltage at stated thickness and electrode configuration
    Peel adhesion to metal surfaceASTM D3330/D3330MPeel force in N/cm after 24 h dwell
    Creepage and clearance for insulation coordinationIEC 60664-1Pollution degree, overvoltage category, comparative tracking index as applicable

    Does the 399FR construction support single-layer wrapping of cable harness breakouts without supplemental heat shrink?

    In aerospace wire harness routing, branch-out junctions are vulnerable to chafing at clamp edges and to arc propagation after a wiring failure. The question of whether one layer of 3M 399FR can replace heavy-wall heat shrink is resolved through a combination of bundle diameter calculations and flammability test data. Under 14 CFR 25.853(a), Appendix F Part I, a 60 s vertical flame exposure is applied to a bundle specimen; acceptance depends on average burn length, flame time after removal, and drip extinguish time specified by the airframer. The glass cloth backing remains dimensionally stable during this exposure and does not shrink away from the splice, while the silicone PSA forms a silicon dioxide char that retains electrical separation. However, single-layer wrapping should not be used where the added diameter exceeds the clamp insert allowance. A single pass with 50% overlap typically adds 0.15 mm to 0.20 mm to the bundle radius; this is not a specification value and must be measured on the actual harness build. Application is performed from a dedicated tape head with a wrap angle of 45° to 60° and a controlled brake setting that avoids weave distortion. Entrapped air pockets are the main process failure mode because they reduce partial discharge inception voltage at altitude. After wrapping, the harness breakout is inspected under a low-magnification lens for edge flags and adhesive ooze. The tape is not a fire zone barrier; if the routing passes through a designated fire zone, fireproof sleeving or clamp-mounted shields are still required. The terminal finished component is a harness breakout subassembly ready for clamp installation. Because adhesive build increases over 24 h at 23 °C, immediate clamp torque should be checked again after the dwell period.

    Dry-type transformer coils wound with rectangular magnet wire require interlayer tapes that survive vacuum pressure impregnation without losing edge tear resistance. The 3M 399FR tape is cut to coil width on a rotary shear; hand cutting is avoided because ragged edges create resin-rich varnish skip defects. During winding, the glass cloth layer prevents turn-to-turn abrasion when the coil is compacted and blocked in the winding fixture. Because the adhesive is a silicone PSA, compatibility with the specific varnish hardener system must be verified; amine-cured epoxy systems may leave unreacted hardener fractions that interfere with silicone PSA peel adhesion, while silicone varnish systems generally present fewer interfacial adhesion problems. A typical vacuum pressure impregnation sequence includes a 105 °C pre-bake for moisture removal, vacuum fill at 2.0 kPa to 5.0 kPa, pressure soak, and final cure in a forced-air oven with a ramp not exceeding 3 °C/min. These parameters belong to the varnish system and are not tape property limits. The tape is not used as the sole turn insulation in Class H (180 °C, IEC 60085) dry-type designs unless the complete insulation system passes IEC 60076-11 or the manufacturer's thermal class test. The glass cloth backing is dimensionally stable in the varnish cure cycle, which prevents layer-to-layer motion and preserves oil-free air gaps. The final component is an encapsulated coil with a smooth, contiguous tape boundary visible before the final resin fill.

    Thermal Blanket Seam Closure for Stainless Steel Foil-Faced Exhaust Insulation Pads

    On gas turbine exhaust diffusers and diesel exhaust ducts, removable insulation pads use a stainless steel foil outer membrane. Seams are overlapped 25 mm and closed with 3M 399FR tape after the foil is wiped with methyl ethyl ketone or an equivalent solvent. The tape adheres to the oxide layer on stainless steel; adhesion is higher on 2B mill finish than on polished mirror finish, but peel testing is recommended because mill finish can vary between batches. Peel adhesion to stainless steel is measured per ASTM D3330/D3330M after 24 h dwell at 23 °C. In this application, the tape functions as a flame-retardant seam cover and low-pressure air seal, not as a structural fastener. Stainless steel lacing wire or band clamps carry mechanical load. The glass cloth backing tolerates intermittent surface exposure but continuous exposure above 200 °C should be avoided because elevated temperature accelerates silicone PSA reversion at the adhesive-substrate interface. No published long-term ageing data for this specific configuration is available; service life should be predicted from pad surface thermocouple records rather than tape supplier figures. The finished pad is fitted over the exhaust flange and secured with lacing wire, with tape seams oriented away from direct water spray and washdown media.

    Thermocouple harnesses routed across furnace shells are exposed to radiant heat and occasional contact with refractory dust. The harness is bundled with 3M 399FR as an outer wrap over mineral-insulated cable or glass-fibre insulated extension wire. Application uses a 50% overlap and continuous tension to prevent dust ingress, but the tape is not a substitute for conduit where mechanical impact or molten splash is present. The glass cloth surface provides cut-through resistance when bundles are pulled over sharp sheet-metal edges. In high-temperature areas above 200 °C, the adhesive alone cannot retain the tape edges; the helix is anchored at each end with a stainless steel band. The assembled harness is routed through ceramic standoffs. Flame retardancy is verified by vertical burn testing for the specific bundle diameter, not on the flat tape alone. The final component is a heat-traced or refractory-side thermocouple bundle with stable routing dimensions for panel termination.

    When peel adhesion of silicone PSA on stainless steel must be verified before coil lashing

    During coil lashing of random-wound motor stators, the tape must hold end-turn blocking in position through varnishing and build-up. A peel test per ASTM D3330/D3330M is performed on a 0.5 mm thick stainless steel panel, not on magnet wire alone, because magnet wire enamel varies in surface energy. The silicone PSA of 3M 399FR typically builds to near final adhesion within 24 h at 23 °C and 50% RH; immediate varnish dip is not recommended unless the coil can be mechanically supported. Wrapping tension during lashing is set just below the point where adhesive ooze appears at the overlap edges. The glass cloth backing provides dimensional stability during oven cure at class F (155 °C) or class H (180 °C) cycles, but the varnish cure profile must not exceed the adhesive’s temperature limit. When the tape is used as a lashing layer, it is not part of the primary conductor insulation; turn insulation remains the magnet wire enamel. End-turn lashing is anchored onto the slot liner so that the glass cloth does not slip during varnish shrinkage. The finished component is a stator ready for final varnish cure.

    Free Quote

    Competitive 3M 399FR Flame Retardant Glass Cloth Tape prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    3M 399FR Flame Retardant Glass Cloth Tape is constructed from a woven glass cloth backing coated with a crosslinked acrylic pressure-sensitive adhesive and supplied in a white finish. Manufacturer’s published typical values for the construction include a total thickness of 0.18 mm (7 mil), composed of a 0.13 mm (5 mil) backing and a 0.05 mm (2 mil) adhesive layer. The tape is recognized as a flame-retardant insulating tape under UL 510 and is specified for electrical and mechanical applications in which a woven glass carrier provides tensile strength and resistance to cut-through. Common roll configurations include 55 m lengths in widths from 25 mm to 100 mm; custom slitting may be available through industrial converters. The product is classified for continuous thermal exposure at 121°C, with intermittent excursions to 149°C. The acrylic adhesive is selected for its balance of ambient-temperature peel performance, oxidation resistance, and compatibility with many coil varnish systems; however, compatibility with specific solvent packages must be verified before production use.

    Why Is UL 510 Recognition Critical in Transformer and Motor Winding Applications?

    UL 510 is a component recognition standard for insulating tape and coated cloth used in electrical equipment. A UL Recognized Component under UL 510 is evaluated for flame propagation and flammability characteristics according to the component construction, not for the finished assembly. In transformer and motor winding applications, 3M 399FR is applied as an outer wrap over coil windings, lead anchors, and bobbin terminations to provide mechanical protection and a flame-resistant barrier. The woven glass cloth backing withstands winding tension during taping, while the low elongation—typically 5% at break—allows controlled placement without excessive stretch. Because UL 510 recognition does not automatically confer end-product approval, final equipment is evaluated under the applicable end-product standard such as UL 1446 for electrical insulation systems or IEC 60085 for thermal evaluation. Adhesive squeeze-out and edge flagging are the primary process failure modes observed on high-speed taping heads; these are controlled by limiting tape tension to less than 10% of the published tensile strength and by maintaining roll alignment within the taping head.

    PropertyTypical valueTest method or standard
    Total tape thickness0.18 mm (7 mil)ASTM D3652/D3652M-20
    Backing thickness0.13 mm (5 mil)ASTM D3652/D3652M-20
    Adhesive thickness0.05 mm (2 mil)ASTM D3652/D3652M-20
    Tensile strength at break263 N/100 mm (150 lb/in)ASTM D3759/D3759M-20
    Elongation at break5%ASTM D3759/D3759M-20
    Adhesion to steel47 N/100 mm (43 oz/in)ASTM D3330/D3330M-20
    Continuous thermal rating121°CManufacturer’s thermal classification
    Intermittent thermal excursion149°CManufacturer’s thermal classification
    Flame retardancyPassUL 510
    BackingWoven glass cloth—
    ColorWhiteVisual

    Adhesion to steel is typically measured at 47 N/100 mm using ASTM D3330/D3330M-20; the value drops on low-surface-energy substrates such as polypropylene, powder-coated surfaces, and silicone-contaminated metals. Surface preparation should include removal of oils and particulates with isopropanol or a 50/50 isopropanol/heptane blend followed by a dry wipe. The tape can be applied at temperatures above 10°C; below this threshold the acrylic adhesive loses wet-out and peel strength. Pressure application should be uniform using a laminating nip or squeegee roller; hand pressure may leave unbonded regions at the tape edges. After application at 21°C to 25°C, the adhesive builds peel strength over a 24 h dwell period. For coil impregnation processes, the tape is often used before varnish dip and cure; the high-thread-count cloth allows some resin penetration at the edge, but full impregnation through the adhesive layer is not expected. Thermal aging above 121°C causes progressive oxidation and embrittlement of the acrylic adhesive, while the glass cloth remains stable to significantly higher temperatures; the continuous thermal rating should not be assigned based solely on the glass backing.

    When Flame Retardant Glass Cloth Tape Replaces Polyimide Film Tape in Appliance and Aerospace Harness Protection

    Polyimide film tape is often selected for high-temperature masking and insulation because of its 260°C thermal class and thin dielectric film; however, polyimide lacks the conformability and abrasion resistance of woven glass cloth. In applications in which harness bundles pass over sharp metal edges or a flame-retardant barrier is required on flexible conduits, 3M 399FR is used as a wrap because the glass cloth distributes mechanical load across the bundle and resists cut-through. The trade-off is thickness: at 0.18 mm total thickness, a single layer consumes more space in tight enclosures than a 0.06 mm polyimide film. Silicone adhesive glass cloth tapes are specified when the continuous temperature exceeds 121°C and silicone adhesive is acceptable; in paint preparation areas, 3M 399FR may be preferred because the acrylic adhesive does not release silicone and does not create surface contamination that can produce fish-eye defects in coatings. The acrylic adhesive is not intended for continuous immersion in ketones, esters, or chlorinated solvents; short-term wipedowns with mineral spirits are tolerated, but immersion leads to adhesive swelling and loss of shear strength.

    RoHS compliance is established under Directive 2011/65/EU as amended by (EU) 2015/863. The product is typically supplied to REACH Regulation (EC) No 1907/2006 requirements; specific candidate-list substances and halogen content should be confirmed with the manufacturer’s current safety data sheet and compliance certificate for the production lot. Flame retardancy is not achieved through polybrominated diphenyl ethers, but the precise flame-retardant chemistry is proprietary. A certificate of analysis may include lot-specific values for total thickness, adhesion to steel, and tensile strength; batch-to-batch variation for these glass cloth tapes is influenced by cloth basis weight and adhesive coat weight within manufacturer-established control limits. For processes requiring dielectric breakdown testing, ASTM D149 values are highly dependent on electrode geometry and humidity; published data for this specific configuration is limited, so the end user should evaluate the taped assembly under the insulation coordination requirements of IEC 60664-1.

    Regulatory or standards dimensionDesignationTypical status
    Restriction of Hazardous SubstancesRoHS Directive 2011/65/EU + (EU) 2015/863Compliant
    Registration, Evaluation, Authorisation and Restriction of ChemicalsREACH Regulation (EC) No 1907/2006Compliance confirmed through SDS; SVHC check per lot
    Flame retardant component recognitionUL 510Recognized Component
    Electrical insulation system compatibilityUL 1446Evaluated in specific insulation systems; not a standalone system classification
    Insulation coordinationIEC 60664-1End-product evaluation required
    Dielectric breakdownASTM D149Lot-specific; electrode and humidity dependent
    Tensile and elongationASTM D3759/D3759M-20Published typical values
    Peel adhesionASTM D3330/D3330M-20Published typical values

    Thermal Aging, Solvent Resistance, and the Limits of Acrylic Pressure-Sensitive Adhesion

    During high-speed coil taping, the tape is subjected to tension, bending, and dwell under pressure. The woven glass cloth exhibits anisotropic tensile behavior: warp-direction strength dominates, while fill-direction tear resistance is lower. Machine-direction tensile values should not be used to estimate cross-web strength. Operators should orient the roll so that the primary tensile load follows the warp direction of the fabric; otherwise edge tearing occurs at slits or guide surfaces. The acrylic adhesive is a crosslinked polymer network with a glass transition temperature below 0°C; at room temperature it behaves as a viscoelastic solid. Initial peel increases with time as the adhesive wets the substrate; this is accelerated at 50°C, where 1 h of dwell can approximate the bond strength achieved after 24 h at 23°C. The low elongation at break—approximately 5%—means the tape cannot be stretched around tight radii without buckling; minimum bend radius should be at least three times the total tape thickness to avoid backing fracture.

    Lot-to-lot variation in glass cloth tapes is observed in basis weight, adhesive coat weight, and release liner noise. The manufacturer establishes control limits around nominal values. For applications classified as safety-critical, incoming inspection should verify thickness using a digital micrometer with a 6.35 mm foot and 50 kPa pressure per ASTM D3652/D3652M-20, and adhesion to stainless steel per ASTM D3330/D3330M-20 using a 300 mm/min crosshead speed. These tests are appropriate for batch release. Out-of-spec adhesion is often caused by adhesive aging or humid storage; rolls should be stored in original polyethylene packaging at 21°C and 50% relative humidity. Rolls should not be stored on their edges for extended periods because glass cloth cores can develop flat spots that produce chatter in automatic taping equipment.

    3M 399FR is not a substitute for silicone-coated glass cloth in Class H motors operating above 180°C, nor is it designed for continuous exposure to transformer oil at elevated temperature. In oil-filled equipment, the acrylic adhesive may soften and lose adhesion if the oil temperature exceeds 105°C. In dry-type transformers, the tape is used as an outer wrap because it provides a flame-retardant barrier and mechanical protection without the high dielectric loss associated with some polymeric films. For busbar insulation, epoxy-coated glass cloth or polyimide film with higher dielectric strength is more frequently specified. The primary differentiation is not high dielectric strength but combined flame retardancy, mechanical toughness, and UL 510 recognition in a single component.

    The UL 510 recognition applies to the supplied composition and construction. Changing adhesive suppliers, backing finish, or coat weight invalidates component recognition; converters should not laminate additional films or adhesives without re-evaluation under UL 510. When the tape is used in an electrical insulation system, compatibility with varnishes and magnet wire enamels must be tested under UL 1446. Incompatibility can appear as loss of bond after varnish cure, discoloration, or cracking of the tape edge. Some polyester-based magnet wire enamels release solvents during cure that can attack acrylic adhesive; a small-coil trial should be run before full production.

    Top