| HS Code | 762231 |
| Product Name | 3M 3367 General Purpose Aluminum Foil Tape |
| Product Type | Aluminum foil tape |
| Backing Material | Aluminum foil |
| Adhesive Type | Acrylic |
| Color | Silver |
| Backing Thickness | 2.0 mil (0.051 mm) |
| Adhesive Thickness | 1.6 mil (0.041 mm) |
| Total Thickness | 3.6 mil (0.091 mm) |
| Adhesion To Steel | 40 oz/in (11 N/25 mm) |
| Tensile Strength | 20 lb/in (350 N/100 mm) |
| Elongation At Break | 5% |
| Operating Temperature Range | -40°F to 250°F (-40°C to 121°C) |
| Flame Retardant | Yes |
| Ul 723 | Yes |
| Moisture Resistance | Yes |
| Vapor Barrier | Yes |
| Roll Length | 60 yd (54.86 m) |
| Core Diameter | 3 in (76.2 mm) |
| Shelf Life | 24 months |
As an accredited 3M 3367 General Purpose Aluminum Foil Tape factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied as rolls in a cardboard case; standard pack quantity is 24 rolls of 3M 3367 General Purpose Aluminum Foil Tape. |
| Container Loading (20′ FCL) | 20′ FCL containing palletized 3M 3367 General Purpose Aluminum Foil Tape, shrink-wrapped, strapped, and evenly distributed for safe ocean shipment. |
| Shipping | 3M 3367 General Purpose Aluminum Foil Tape is not regulated for transport. It is not classified as a hazardous material/dangerous good. No UN number, proper shipping name, hazard class, or packing group is required. Ship in original packaging via ground, air, or ocean; keep dry and avoid extreme heat. |
| Storage | Store 3M 3367 General Purpose Aluminum Foil Tape in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, flames, and moisture. Keep rolls in sealed original packaging, upright, at 16–27°C (60–80°F). Avoid freezing, heavy stacking, dust, solvents, acids, oxidizers, and food/feed contamination. Do not store near ignition sources. Rotate stock FIFO; inspect packaging before use. |
| Shelf Life | 24 months from manufacture when stored in original packaging at 60–80°F and 40–60% relative humidity. |
3M 3367 General Purpose Aluminum Foil Tape is constructed with a dead-soft 0.05 mm (2.0 mil) aluminum foil backing and a pressure-sensitive acrylic adhesive layer. The backing-to-adhesive thickness ratio is 2.0:1.3, yielding a nominal total caliper of 0.083 mm (3.3 mil). The specification values below are extracted from the supplier technical data sheet and define the processing envelope for the downstream applications in this section.
| Property | Test method | Numerical value |
|---|---|---|
| Total tape thickness | ASTM D3652/D3652M | 0.083 mm (3.3 mil) |
| Aluminum foil backing thickness | ASTM D3652/D3652M | 0.05 mm (2.0 mil) |
| Acrylic adhesive layer thickness | manufacturer calculation | 0.033 mm (1.3 mil) |
| Backing-to-adhesive thickness ratio | manufacturer calculation | 2.0:1.3 |
| Adhesion to steel, 180° peel | ASTM D3330/D3330M-02 | 25 oz/in (2.7 N/10 mm) |
| Tensile strength at break | ASTM D3759/D3759M | 17 lb/in (298 N/100 mm) |
| Elongation at break | ASTM D3759/D3759M | 5% |
| Continuous service temperature range | supplier technical data sheet | -29°C to 121°C |
Within sheet metal fabrication facilities, longitudinal Pittsburgh lock seams and transverse TDC/TDF flanges on galvanized steel air distribution ducts are sealed using a continuous foil tape cap strip. Under the SMACNA HVAC Duct Construction Standards—Metal and Flexible, 3rd edition, duct closure is specified by Seal Class A, B, or C; Class A and Class B joints require longitudinal seams and transverse joints to be sealed before closure. ANSI/ASHRAE 90.1, Section 6.4.4.2, requires duct leakage testing for high-pressure sections and mandates that pressure-sensitive tapes used for duct closure be listed to UL 723/ASTM E84 for surface burning characteristics. The 3367 tape carries UL 723/ASTM E84 classification documentation; current certificates should be obtained from the manufacturer for batch-specific flame spread and smoke developed values. Material consumption is calculated as 1.05–1.20 linear metres of 50.8 mm wide tape per linear metre of assembled joint, assuming 25 mm minimum edge overlap, 50 mm corner returns on TDF/TDC gussets, and 5–10% roll handling waste. The production sequence includes alkaline degreasing of formed flange surfaces, forced-air drying to remove alkaline rinse water, mechanical flange bolting, and tape application with a pneumatic squeeze roller or automated gantry taping head at 20–30 m/min. Roller pressure is set to 4–6 N/cm of width so the acrylic adhesive flows into the Pittsburgh lock seam and the flange overlap without necking the 0.05 mm foil. Tape applied below 5°C is pre-conditioned in a 15–25°C staging area because acrylic pressure-sensitive adhesive wet-out on zinc-coated steel deteriorates outside this processing window. Finished outputs are rectangular and spiral galvanized steel supply, return, and exhaust duct sections rated for low- and medium-pressure commercial HVAC systems; the tape is not used as the sole mechanical connection and is limited to sealing, not load-bearing closure.
Foil-faced glass fiber and mineral wool duct wrap assemblies depend on continuous aluminum foil lap sealing to maintain the vapour retarder plane. ASTM C1136-21 classifies flexible vapour retarder materials by permeance, and ANSI/ASHRAE 90.1, Section 6.4.4.1.2, requires duct insulation to be continuous with the vapour barrier sealed at all joints. The tape is applied as a 75 mm wide lap strip over the factory-applied aluminum foil/kraft facer, with 25 mm of adhesive contact on each adjacent facer. Application rate is 1.2 linear metres of tape per linear metre of longitudinal lap for 1219 mm wide duct wrap, rising to 1.4 linear metres per metre when round duct circumferential butt joints are double-wrapped. The production process begins after the glass fiber blanket is pinned or stapled to the sheet metal duct at 150–200 mm intervals; the facer laps are dry-wiped, and the tape is dispensed at 15–25°C under a J-roller at 4–6 N/cm to eliminate air channels. On spiral duct, the tape is applied with a 50% helical overlap using a constant-tension dispenser to avoid foil necking. Vapour retarder continuity is checked by visual inspection of silver-edge wetting or by non-destructive differential pressure trace gas testing. Terminal products are foil-faced duct wrap assemblies on rectangular, round, and oval supply-air ducts in plant rooms and ceiling return plenums. Published data for tape adhesion to high-embossed foil facers is limited; qualification on a production sample is recommended when facer surface roughness exceeds 50 µm Ra.
Walk-in cold room panels and refrigerated display cabinet shells are fabricated from polyurethane foam-filled, aluminum-skinned or polyester-laminated galvanized steel panels; perimeter joints are sealed with 3367 to limit moisture vapour ingress and surface condensation. The relevant panel product standard EN 14509-2013 for self-supporting double skin metal-faced insulating panels sets factory production control and thermal performance requirements; installed panels are air leakage tested to EN 12114, and refrigerated display cabinets are evaluated to ISO 23953-2:2015 for cabinet surface condensation and temperature pull-down. Tape application rate on 1200 mm × 2400 mm panel joints is 1.4 linear metres of 75 mm tape per linear metre of vertical joint, including 50 mm corner returns and 25 mm end laps; a single panel perimeter consumes 7.2 m of tape. Joint surfaces are cleaned with a 70:30 isopropanol/water solution and dried; the tape is applied at 15–30°C with a silicone rubber layup roller at 0.2 MPa minimum face pressure to flow the acrylic adhesive into embossed metal or polyester lacquer. Tape tension must not exceed 5 N/cm, because dead-soft foil necks over panel edge radii and produces latent tearing under thermal cycling. Panels are locked with eccentric cam devices and foam-in-place gaskets; the tape is the external vapour seal, not the structural lock. Finished products are walk-in coolers, blast freezer rooms, refrigerated display cabinets, and cold-chain distribution enclosures operating between -40°C and +5°C internal air temperature. The tape is not recommended for continuous water immersion or unprotected external UV exposure; edge lifting at the panel cut surface is the principal field failure mode and requires a 10 mm minimum foil fold-over.
In off-highway equipment, small-diameter engine compartment wire harness branches routed within 80–120 mm of a radiant heat source are sometimes wrapped with a reflective aluminum foil tape instead of heat-set nylon or silicone-coated fiberglass sleeving. The 3367 acrylic adhesive limits the tape to 121°C continuous service on the backing surface; qualification to ISO 6722-1:2011 cable conductor and insulation tests is required. Under-hood flammability evaluation is carried out to ISO 3795/FMVSS 302 when harness branches pass through cabin bulkhead penetrations. The wrap configuration is a 50% overlapping spiral, consuming 2.0 linear metres of 25 mm wide tape per linear metre of 15 mm outer-diameter harness; the adhesive is laid over the preceding tape layer rather than directly on wire insulation where a continuous foil outer surface is needed. Production equipment includes a motorized vertical wrapping head running at 40–60 rpm with a 0.5–1.0 kg roller contact force; the harness fixture must support the branch-out to prevent foil edge gouging into thin-wall PVC or XLPE insulation. After wrapping, assemblies are conditioned at 90°C for 30 minutes to stabilize acrylic adhesion before routing. Terminal products are engine-bay and chassis harness assemblies for off-highway equipment, agricultural tractors, and aftermarket thermal protection retrofits. Published data for this specific OEM configuration are limited; cyclic thermal shock from -40°C to 105°C and chemical resistance to engine fluids must be validated against the end-user material specification before production release.
Foil-faced polyisocyanurate and phenolic foam board joints in building envelope wall and roof assemblies are sealed to maintain air barrier continuity and limit inward water vapour diffusion. The 3367 tape can be used over factory-applied aluminum foil facers; compliance is evaluated to IECC 2021, Section C402.5, for air leakage control and ASTM E2357/E2357M-18 for air barrier assembly performance. Application rate for 1220 mm × 2440 mm boards is 4.88 linear metres of 50 mm wide tape per board, with 25 mm minimum contact to each board edge; wall corner and opening returns increase consumption by 8–12%. Board facers must be dry, frost-free, and above 2°C; joints wider than 3 mm require backer rod or approved joint filler before tape application. The tape is applied with a steel or nylon roller to densify adhesive-facer contact; on vertical wall sheathing, application proceeds from bottom to top so the upper tape edge sheds water. The tape is not a primary weather-resistant barrier and is not intended for extended exterior UV exposure. Terminal products are air-tight insulated wall, roof, and foundation enclosure assemblies behind cladding, masonry veneer, or roofing membranes.
In continuous process plants, 3367 is used for non-structural patching of low-pressure dust extraction ducting, temporary masking of flanged connections during shutdowns, and bundling of small-diameter pneumatic control lines. The tape is validated to ASTM D3759/D3759M tensile strength 17 lb/in (298 N/100 mm) and ASTM D3330/D3330M-02 peel adhesion to steel 25 oz/in (2.7 N/10 mm); service temperature is limited to -29°C to 121°C. For a non-pressurised 100 mm × 100 mm opening in a dust collector duct, a three-layer patch is used: the first layer extends 40 mm beyond the opening on all sides, the second layer overlaps the first by 25 mm, and the third layer extends 60 mm beyond the second, yielding a total tape usage of approximately 0.21 m² per 0.01 m² opening. The process follows plant maintenance procedure: lockout and isolation, solvent degreasing with isopropanol or methyl ethyl ketone, removal of loose oxide with an abrasive pad, and patch application from centre outward with a paper-faced steel roller. The completed patch is inspected for foil cracks and edge voids; repairs in continuous positive-pressure ducts are not permitted with this tape. Terminal products are temporary-repaired galvanized and aluminum process duct sections, temporary caps on flanged lines, and bundled pneumatic or instrumentation line groups during turnaround maintenance. The tape is not approved for pressure vessel repair, structural load transfer, or direct contact with food-processing streams.
Competitive 3M 3367 General Purpose Aluminum Foil Tape prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
3M 3367 General Purpose Aluminum Foil Tape is manufactured as a single-coated pressure-sensitive tape with a dead-soft aluminum foil backing and an acrylic adhesive. The manufacturer's published technical data identify a backing thickness of 2.0 mil (0.05 mm), an adhesive dry thickness of approximately 1.6 mil (0.04 mm), and a nominal total thickness of 3.6 mil (0.09 mm). The product is intended for seaming and sealing air-handling ductwork, insulation facings, metal panels, and light-gauge aluminum cladding. Because the foil backing is dead-soft, the tape conforms to irregular seams and corner transitions without edge lift. The standard configuration is supplied without a release liner, which permits rapid manual or semi-automated application. The exposed adhesive can collect airborne dust and fiber debris if the roll is staged for long periods in a production environment.
Mechanical behavior of the tape is controlled by the foil backing rather than by the acrylic adhesive layer. The backing yields at low elongation and does not behave like a polymeric film tape under load. When a sealed joint opens, stress concentrates at the foil edge and the dead-soft aluminum deforms plastically. With a published elongation at break of only 5%, the tape can crack rather than stretch if joint movement exceeds the foil yield strain. This property defines the operational boundary in duct systems that experience vibration, thermal expansion, or pressure cycling. The acrylic adhesive can redistribute shear stress over a narrow region at low deformation rates, but it does not increase the elongation capacity of the backing. Published fatigue data for this specific configuration is limited; therefore, the product should not be used wherever the sealed joint is mechanically active or pressurized above the manufacturer's recommended static load.
The pressure-sensitive adhesive builds bond through wet-out, not through crosslinking or cure. Short dwell times after application yield lower peel adhesion than the published values, which are typically obtained after a controlled dwell period. Full adhesion development may require several hours at room temperature. In production operations, immediate handling of freshly taped assemblies should be minimized when high peel loads are expected. Shear holding capacity is a separate consideration from peel adhesion. For applications involving sustained static load or constant peel force, comparative testing under ASTM D3654/D3654M is recommended. Published shear data for 3M 3367 specifically is limited, so process validation should include shear testing on the actual substrate and at the upper service temperature of the proposed application.
The representative property profile published for 3M 3367 General Purpose Aluminum Foil Tape is summarized in the table below. These values are obtained under standard laboratory conditions and are not intended as specification limits for every production lot.
| Property | Test method | Representative value |
|---|---|---|
| Total thickness | ASTM D3652/D3652M | 3.6 mil (0.09 mm) |
| Backing thickness | ASTM D3652/D3652M | 2.0 mil (0.05 mm) |
| Adhesive thickness | ASTM D3652/D3652M | 1.6 mil (0.04 mm) |
| Peel adhesion to stainless steel | ASTM D3330/D3330M | 40 oz/in (43.8 N/100 mm) |
| Tensile strength at break | ASTM D3759/D3759M | 25 lb/in (438 N/100 mm) |
| Elongation at break | ASTM D3759/D3759M | 5% |
| Service temperature range | Manufacturer data | -40°F to 250°F (-40°C to 121°C) |
Peel adhesion is the most commonly misread value in this data set. A peel value of 40 oz/in (43.8 N/100 mm) is measured against clean stainless steel under controlled temperature, humidity, peel angle, and dwell time. On production surfaces of galvanized steel, the measured peel value can be lower because zinc oxidation, oil carryover, and surface roughness change the wet-out behavior. The tensile strength of 25 lb/in (438 N/100 mm) and elongation at break of 5% reflect the aluminum backing; they place the product in a general-purpose foil class with lower tensile capacity than heavy-duty foil tapes. The service temperature range of -40°F to 250°F (-40°C to 121°C) is a thermal boundary for the system. At 250°F (121°C), the acrylic adhesive softens and shear holding capacity decreases. At -40°F (-40°C), adhesion build is minimal because the adhesive cannot flow into surface micro-roughness. The aluminum foil remains intact at low temperatures, but low-temperature application is not equivalent to low-temperature service.
In below-ambient duct applications, the tape functions as both a vapor-barrier seam closure and a mechanical seal. Moisture ingress is driven by the water vapor pressure difference across the insulation facing. The aluminum foil backing is an effective vapor barrier, but the seam is only as continuous as the adhesive contact area. A discontinuous bond line forms channels through which humid air can pass. Because the pressure-sensitive adhesive does not cure, it remains susceptible to creep under sustained shear loading. If the duct operates at low temperature, condensation can form on the inner metallic face before tape application. Cleaning alone does not solve this; the surface must be raised above the dew point. Manufacturer technical guidance for acrylic pressure-sensitive tapes generally specifies application temperatures above 10°C (50°F), and chilled substrates require active warming. Even at an acceptable temperature, roller pressure must be applied from center to edge to expel air bubbles. Entrapped air bubbles reduce contact area and can become condensate channels under thermal cycling. In field inspections, edge lift on insulated ductwork is often associated with low surface temperature during installation, not with bulk adhesive failure.
When 3M 3367 is used over insulation facing made from polyolefin or another low-surface-energy polymer, adhesion can be insufficient without surface treatment. Acrylic adhesives typically wet substrates with surface energy above 38 dyn/cm. Many untreated polyolefin facings fall below that threshold, so corona or plasma surface treatment may be required to improve adhesion. Published data for this specific tape on treated polyolefin insulation facing is limited; trials should be conducted with the production facing and the planned surface-treatment level.
Surface contamination is a dominant variable in production metal panel sealing. Oils, mill scale, zinc spangle, silicone lubricants, and finger oils reduce the surface energy of the metal and block adhesive contact. The minimum practical cleanliness criterion is a water-break-free surface. If water beads, the surface is not sufficiently clean. In many production lines, the cleaning sequence includes a dry wipe to remove particulates, followed by isopropanol or another fast-drying solvent. However, solvent wiping can concentrate contaminants along the wipe path if the cloth is not replaced frequently. On heavily oxidized galvanized steel, light mechanical abrasion with a non-metallic abrasive increases surface area and removes loose zinc corrosion products. Published data for this specific tape on abraded galvanized metal is limited; therefore, production specifications should include peel-adhesion verification using representative metal coupons rather than relying solely on the published stainless-steel value.
The adhesive layer is viscoelastic. Its wet-out behavior depends on temperature, time, and applied pressure. In high-speed application systems, dwell time between tape application and final press may be insufficient to develop full bond. Double-roller application with controlled nip pressure can reduce air entrapment. Unwind tension must be kept low enough to avoid necking the dead-soft foil; excessive tension deforms the foil before it reaches the substrate, causing curl and edge lift. In automated lines, tape path idlers should be cleaned periodically to prevent adhesive transfer from exposed edges.
Relative to other foil tapes in the same manufacturer family, 3M 3367 is a general-purpose product with a lower foil caliper and lower tensile strength than heavy-duty alternatives. Heavier-backed foil tapes are specified when puncture resistance, cut resistance, or tensile strength is the controlling requirement. By contrast, 3M 3367 is selected where low total thickness and dead-soft conformability are priorities. When compared with foil tapes using natural rubber pressure-sensitive adhesives, the acrylic adhesive of 3367 provides improved resistance to ultraviolet degradation and oxidation, but may exhibit lower initial tack on low-energy substrates. The product should not be considered equivalent to aluminum-backed butyl tapes or mastic sealants. Butyl and mastic systems form a bulk sealant or a thicker flexible joint, whereas 3M 3367 remains a thin pressure-sensitive bond. Consequently, 3367 does not provide the same gap-filling capacity on irregular or expanded metal seams. A bead of mastic or a thicker butyl tape may be required when gaps exceed the combined caliper of the foil and adhesive.
In plasticizer-rich environments, especially flexible PVC jacketing, the acrylic adhesive may lose peel resistance as plasticizer migrates across the interface. This is an incompatibility boundary. The tape should not be used against plasticized PVC unless a barrier or a different adhesive system is specified. In outdoor exposure, the aluminum foil resists water vapor and ultraviolet radiation; however, the foil can oxidize slowly and may show surface haze without immediate loss of seal. Long-term exposure to salt spray or industrial acids may corrode the foil edge and undercut the adhesive bond. The backing is electrically conductive and should be kept away from exposed electrical terminations. For HVAC duct sealing applications, the relevant surface-burning or fire-hazard classifications should be verified against current manufacturer compliance documentation; the presence of a metallic backing alone does not exempt a composite tape from code requirements.
Published data for this specific product on long-term cyclic humidity aging, salt spray exposure, and fatigue under positive duct pressure is limited. Therefore, engineering specifications should include performance testing under the actual substrate, operating temperature, and pressure conditions. The product is intended for general-purpose sealing, patching, and seaming; it is not a substitute for welded, riveted, or mechanically fastened structural connections.