    HS Code 410878
    Tensilestrength 8,700 psi (60 MPa)
    Tensilemodulus 330,000 psi (2,275 MPa)
    Tensileelongationatbreak 3%
    Flexuralstrength 15,000 psi (103 MPa)
    Flexuralmodulus 360,000 psi (2,480 MPa)
    Notchedizodimpact 1.0 ft-lb/in (53 J/m)
    Heatdeflectiontemperatureat264psi 372 °F (189 °C)
    Heatdeflectiontemperatureat66psi 405 °F (207 °C)
    Glasstransitiontemperature 230 °C (446 °F)
    Density 1.29 g/cm³
    Dielectricstrength 400 V/mil
    Dielectricconstant 3.5
    Waterabsorption 0.37%
    Coefficientofthermalexpansion 3.1E-5 in/in/°F
    Flammability UL94 V-0

    As an accredited 3D Systems Fused Deposition Modeling Material PPSF factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Application of 3D Systems Fused Deposition Modeling Material PPSF

    Aerospace cabin ECS ducting fabricated from the 3D Systems FDM PPSF filament requires documentation of 100 wt% virgin polyphenylsulfone resin with 0 wt% regrind and a pre-extrusion moisture content of ≤0.02 wt% by Karl Fischer titration to satisfy flammability test lot traceability under 14 CFR 25.853(a) and 14 CFR 25.853(d). After filament drying at 121 °C for 4 h, the material is run through a high-temperature FDM head with a 0.40 mm nozzle at a barrel setpoint of 370–380 °C, while the build chamber is controlled to 150 °C with a surface-temperature deviation of ±5 °C; a 0.178 mm layer height is imposed on thin-wall duct sections to reduce interlayer voids that act as smoke-release sites during post-crash fire events. The lower process boundary is defined by chamber surface temperature falling below 145 °C, at which point interlayer peel strength drops below the threshold required for pressure-cycle durability; the upper boundary is marked by extruder residence times above 15 min at 390 °C, producing amber molecular-weight degradation. Terminal part forms include cabin ECS riser adapters, avionics cooling plenum boots, and air mixer brackets, all of which are annealed at 180 °C for 2 h before vertical-burn coupon extraction.

    What Autoclave Cycling Thresholds Force Design Changes in Printed Surgical Instrument Components?

    Steam sterilisation of reusable surgical tray components fabricated from FDM PPSF is evaluated under ISO 17665-1:2006 for moist heat sterilisation and ISO 10993-1:2018 for biological evaluation, with the resin used in its 100 wt% unfilled form without impact modifiers or processing aids because addition of lower-Tg polymers would reduce the heat deflection temperature below the 134 °C autoclave exposure requirement. The filament is dried to ≤0.02 wt% moisture and printed at 375 °C barrel setpoint, 150 °C chamber, 0.178 mm layer height, and 100% infill to minimise porosity that would retain biological residue after cleaning. The main process conflict occurs in post-print annealing: temperatures below 180 °C leave residual stress that causes warpage during steam exposure, while temperatures above 200 °C allow creep-induced distortion of thin wall sections because the glass transition temperature of polyphenylsulfone is approximately 220 °C. Parts are therefore annealed in a circulating-air oven at 185–195 °C for 2 h, then washed with alkaline detergent at pH 10–11 and steam-sterilised at 134 °C for 3 min in a vacuum autoclave. Documented terminal items include instrument tray brackets, endoscope holder inserts, and sterilisation cassette rails for central sterile services departments. Published data for repeated gamma irradiation above 40 kGy on this specific filament lot configuration is limited; steam sterilisation remains the documented design basis.

    Chlorinated Alkaline Stream Exposure for Chemically Aggressive Flow Cells and Sensor Housings

    Chlorinated alkaline process streams impose simultaneous demands on flow-cell and sensor-housing materials; the unfilled PPSF filament grade is therefore processed at 100 wt% polyphenylsulfone with no plasticiser, no impact modifier, and no glass-fibre reinforcement because the inclusion of a 30 wt% glass-filled PPSU compound would raise melt viscosity beyond the stable extrusion window and increase nozzle wear without improving interlayer fusion. Chemical resistance is screened according to ASTM D543-21 immersion testing, while environmental stress cracking resistance is evaluated against ISO 22088-3 for bent-strip exposure to chlorinated alkaline cleaner at 70 °C. The downstream production route uses a 0.254 mm layer height at 375–385 °C extruder setpoint and 150 °C chamber temperature, followed by annealing at 190 °C for 2 h and single-point machining of threaded ports to ISO 228-1 G1/2 dimensions. The process conflict is that insufficient chamber heating creates continuous interlayer channels that serve as crack initiation sites under alkaline stress cracking, while excessive barrel residence time above 390 °C causes chain scission that is detected as a drop in melt viscosity and yellowing of the machined surface. Terminal forms include caustic flow-cell bodies, pH sensor housings, and sparger bodies in water-treatment and metal-finishing lines.

    After drying at 121 °C for 4 h to a Karl Fischer moisture content of ≤0.02 wt%, unfilled PPSF filament is printed into downhole MWD/LWD connector insulator bodies with a 0.178 mm layer height and 100% infill; the material formulation is held at 100 wt% virgin unfilled PPSF because brominated flame-retardant or carbon-black additions degrade the dielectric strength required across high-pressure feedthrough bores. Electrical creepage and clearance design follows IEC 60664-1 Pollution Degree 3, and flammability is verified to UL 94 V-0 at 1.5 mm thickness. The production route uses a build chamber held at 150 °C; after support removal, the printed blank is annealed at 200 °C for 2 h and then single-point bored to maintain radial runout below 0.05 mm for sealed feedthrough assemblies. Terminal items include MWD probe bushings, LWD sensor isolators, and downhole connector backshells used in oil-based drilling mud service. Long-term compatibility with oil-based mud at 150 °C should be confirmed by ASTM D543-21 immersion testing on production-representative coupons because published data for this specific printed configuration is limited.

    Application sectorPrimary standardTest method / conditionTypical acceptance criterion
    Aircraft cabin interior14 CFR 25.853(a),(d)Vertical burn / OSU heat releasePass on 0.178 mm annealed coupons
    Reusable surgical tray componentsISO 17665-1:2006, ISO 10993-1:2018Moist heat sterilisation / biological evaluation134 °C, 3 min autoclave exposure
    Chemical flow cells and sensor housingsASTM D543-21, ISO 22088-3Immersion / bent-strip environmental stress cracking70 °C chlorinated alkaline cleaner
    Downhole connector insulatorsUL 94 V-0, IEC 60664-1Flammability / creepage and clearance1.5 mm thickness, Pollution Degree 3
    Pharmaceutical format partsUSP <88> Class VISystemic injection / intracutaneous reactivity0.5 wt% max TiO₂
    Test sockets and interconnectsUL 94 V-0, IEC 60243-1Flammability / dielectric breakdown1.5 mm thickness, 0.178 mm layer

    When Dry-Heat Sterilisation Replaces Steam in Pharmaceutical Packaging Format Parts

    In pharmaceutical packaging lines, dry-heat sterilisation at 180 °C imposes a thermal load close to the continuous-use boundary of unfilled PPSF; FDM PPSF change parts are therefore assessed under USP <88> Class VI biological reactivity testing for systemic injection and intracutaneous contact, and the base resin fraction is maintained at 100 wt% unfilled PPSF with titanium dioxide colourant permitted only up to 0.5 wt% when colour-coded format parts are required; no recycled PPSF is introduced into lot batches. The production process begins with filament drying to ≤0.03 wt% moisture, printing at 0.254 mm layer height and 370–380 °C extruder setpoint with a 150 °C chamber, followed by annealing at 180 °C for 2 h and dry-heat sterilisation at 180 °C for 3 h in a convection oven. Because the glass transition temperature of PPSF is near 220 °C, dry-heat exposure is close to the upper continuous-use boundary; unsupported thin-wall parts can creep during the sterilisation hold, so fixtures or design ribs are required to maintain dimensional stability. Terminal part forms include blister packaging format changeparts, tablet deduster guides, and vial transfer grippers for aseptic fill lines. Direct food-contact status for a specific resin lot must be confirmed against the applicable food-contact regulation in the destination market; FDA 21 CFR compliance is not automatically satisfied by the FDM part unless the printed surface is sealed and the resin supplier has issued a compliance letter for the filament.

    Reducing Dielectric Loss in High-Temperature Test Sockets and Electrical Interconnects

    Dielectric loss in high-temperature test sockets is addressed by the unfilled PPSF filament grade at 100 wt% base resin without carbon black or metal-fibre addition; conductive fillers would raise dissipation factor in the 1 MHz–10 GHz measurement range. Material flammability is verified to UL 94 V-0 at 1.5 mm, and dielectric breakdown is evaluated according to IEC 60243-1. Printing uses a 0.178 mm layer height and 150 °C chamber at 375 °C extruder setpoint, then the printed blank is annealed at 190 °C for 2 h before press-fit pin insertion. Terminal products are burn-in socket frames, high-temperature test jacks, and connector insulator carriers used in back-end semiconductor test.

    Free Quote

    Competitive 3D Systems Fused Deposition Modeling Material PPSF prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction
    Among high-temperature extrudable amorphous thermoplastics, 3D Systems Fused Deposition Modeling Material PPSF is a polyphenylsulfone-based part material supplied as a sealed cartridge for heated-chamber Fused Deposition Modeling. The material is characterized by a reported glass transition temperature of 230 °C by dynamic mechanical analysis, a heat deflection temperature of 189 °C at 1.82 MPa under ASTM D648, and a UL 94 V-0 flame rating at a typical test thickness of 1.5 mm. Those values exceed the corresponding thermal limits for ABS and polycarbonate FDM feedstocks and place PPSF in hot-gas duct test articles, chemical-processing fixtures, and steam-sterilizable trial devices. Printed articles are not isotropic; tensile properties in the build direction are typically lower than in the XY plane, and orientation-specific validation to ASTM D638 is required before load-bearing use. The cartridge is qualified for use only on 3D Systems FDM platforms that maintain a heated build envelope and accommodate high-temperature part material with a matched soluble support.

    Thermal Deformation and Flammability Boundaries

    At 0.455 MPa flexural stress, the heat deflection temperature is reported at 207 °C under ASTM D648; at 1.82 MPa the value falls to 189 °C because the amorphous network softens gradually rather than undergoing a sharp crystalline melt. The coefficient of linear thermal expansion for polyphenylsulfone is approximately 55 µm/m·K by ASTM E831; this value, combined with the high build-chamber temperature, requires that the part be cooled uniformly after deposition to minimize warpage in thick cross-sections. Flammability classification is V-0 under UL 94 when tested at 1.5 mm; however, flame performance depends on infill density, wall thickness, and layer fusion, so certification testing must be performed on production-representative printed specimens. Continuous exposure above 180 °C can produce oxidative embrittlement over extended service intervals; published oxidative-aging data for the FDM grade in circulating hot air are limited, and long-term use should be screened by ISO 4589-2 oxygen-index testing or equivalent oven-aging protocols. Annealing printed components near 200 °C can reduce residual stress but may alter dimensions by annealing shrinkage; dimensional compensation factors should be developed from representative build orientations before release.
    Property Typical value Test method
    Density 1.28 g/cm³ ASTM D792
    Tensile strength 55 MPa ASTM D638
    Tensile modulus 2,100 MPa ASTM D638
    Flexural strength 96 MPa ASTM D790
    Flexural modulus 2,100 MPa ASTM D790
    Notched Izod impact 37 J/m ASTM D256
    Elongation at break 3 % ASTM D638
    Heat deflection temperature at 0.455 MPa 207 °C ASTM D648
    Heat deflection temperature at 1.82 MPa 189 °C ASTM D648
    Glass transition temperature 230 °C Dynamic mechanical analysis
    Flame rating V-0 UL 94
    Water absorption, 24 h 0.37 % ASTM D570
    Fused Deposition Modeling deposits raster roads in the XY plane; consequently, the printed part exhibits anisotropic tensile and impact behavior. Tensile modulus in the Z direction can be reduced by 2040 % depending on layer height, air gap, and chamber uniformity; published data for this specific PPSF grade under controlled Z-axis tensile testing is limited, so mechanical requirements should be verified by ASTM D638-14 specimens machined from production-representative orientations. Interlayer shear strength is sensitive to chamber temperature and raster containment; a drop of 10 °C in build-chamber setpoint can produce visible delamination in thick cross-sections. The tabulated values are representative of flat XY specimens and do not apply to Z-axis loading. Because amorphous polyphenylsulfone absorbs moisture from ambient air, storage outside a sealed cartridge at relative humidity above 60 % can raise the water content to a level that generates steam voids during extrusion. Pre-drying is mandatory; typical industrial practice for PPSU filament involves 4 to 6 h at 120150 °C in a desiccant dryer with a dew point below -29 °C, and the residual moisture should be confirmed below 0.02 % by Karl Fischer titration according to ISO 15512. Batch-to-batch variation in melt volume-flow rate, measured at 365 °C and 5.0 kg following ISO 1133-1:2022, affects road spreading and interlayer coalescence; process-control records should track MVR values to avoid stepped changes in part density. Feedstock ovality is controlled by laser micrometry during spooling, but feed-gear slip can occur if the cartridge is handled outside the manufacturer's temperature envelope. Build-chamber stabilization before deposition prevents localized cold spots at the part perimeter, which are a known source of edge delamination in production-scale heated-chamber platforms.

    What Distinguishes PPSF from Polycarbonate and ABS-M30 in FDM Tooling?

    Polycarbonate FDM feedstocks typically exhibit a tensile strength around 52 MPa and a heat deflection temperature near 127 °C at 1.82 MPa, whereas ABS-M30 is reported at approximately 36 MPa and 96 °C at 0.455 MPa. PPSF therefore provides a higher thermal ceiling but not the highest short-term tensile strength available in FDM; polyetherimide grades such as ULTEM 9085 are reported near 68 MPa with a lower heat deflection temperature of 153 °C at 1.82 MPa. The tensile strength of PPSF is approximately 19 % lower than that of PEI 9085, while the HDT at 1.82 MPa is 36 °C higher. Compared with polycarbonate, PPSF offers a 62 °C higher heat deflection temperature at the same 1.82 MPa stress, but its elongation at break of 3 % indicates lower ductility. The principal selection driver for PPSF is the combination of steam autoclave tolerance, broad pH resistance, and flame rating rather than peak tensile strength or impact.

    When the Application Demands Chemical Sterilization at 134°C

    Steam autoclave cycles at 134 °C are used for wrapped instruments and certain laboratory fittings; PPSF is selected when polycarbonate and ABS parts lose dimensional stability or undergo hydrolysis. The material retains stiffness above autoclave temperatures because its heat deflection temperature at 1.82 MPa is 189 °C, but thin-wall components can still creep under clamp load during repeated exposure. Medical trial devices printed from PPSF must comply with ISO 17665-1 for moist-heat sterilization validation and ISO 10993-1 for biological evaluation; the porous external surface of an FDM part may require sealing or high-temperature vapor smoothing before terminal sterilization. The base polyphenylsulfone chemistry is often supported by USP Class VI data, but the printed construction is not automatically equivalent to a molded article, and leachables testing should follow the intended contact route. Chemical sterilants that contain strong oxidizing agents should be evaluated separately; published compatibility data for this specific FDM grade under repeated vaporized hydrogen peroxide exposure are limited. Where process trays are exposed to 30 % sulfuric acid, sodium hydroxide neutralization baths, or aliphatic hydrocarbon rinses, PPSF is screened by immersion testing under ASTM D543; the material is generally resistant. Environmental stress cracking has been observed in chlorinated solvents and polar aprotic solvents such as methylene chloride and dimethylformamide, so these fluid classes should be excluded from service unless validated under the exact molded-in stress state of the printed part. Continuous exposure to hot hydraulic fluids warrants dynamic mechanical analysis after fluid saturation because solvent uptake can lower the glass transition. The V-0 rating does not by itself satisfy aircraft-interior certification; 14 CFR 25.853 and associated OSU 65/65 heat-release requirements require specimen-level testing from the same print orientation and wall thickness used in the final part. Published data for this specific FDM configuration under combined chemical and thermal load are limited, so pre-production validation on production-representative build orientations is necessary.
    Top