| HS Code | 134420 |
| Color | Amber |
| Density | 1.13 g/cm³ |
| Viscosity | 250 cps at 30°C |
| Tensile Strength | 65 MPa |
| Tensile Modulus | 2,800 MPa |
| Elongation At Break | 3.5% |
| Flexural Strength | 110 MPa |
| Flexural Modulus | 2,900 MPa |
| Hardness | 90 Shore D |
| Heat Deflection Temperature At 0 45 Mpa | 200°C |
| Heat Deflection Temperature At 1 82 Mpa | 120°C |
| Glass Transition Temperature | 140°C |
| Coefficient Of Thermal Expansion | 70 µm/m/°C |
| Dielectric Constant At 1 Mhz | 3.5 |
| Dielectric Strength | 15 kV/mm |
| Water Absorption | 0.3% |
As an accredited 3D Systems Accura SL 5530 High temperature resistant Stereolithography material factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
Competitive 3D Systems Accura SL 5530 High temperature resistant Stereolithography material prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The 3D Systems Accura SL 5530 material is a high-temperature-resistant stereolithography resin formulated for solid-state laser photopolymerization platforms. The cured network is a rigid thermoset, formed by cationic polymerization of epoxide-bearing monomers, that after UV and thermal post-cure develops a heat deflection capability substantially above that of general-purpose SLA resins. Manufacturer data sheet values for post-cured specimens generated under ASTM D648 place the heat deflection temperature at 250–290 °C at 0.46 MPa and 110–125 °C at 1.82 MPa. Tensile properties measured according to ASTM D638 fall into a tensile strength range of 45–55 MPa, tensile modulus of 2.8–3.2 GPa, and elongation at break of 1–2%. Flexural strength under ASTM D790 is typically 70–90 MPa, and notched Izod impact under ASTM D256 is generally below 20 J/m. Because the elongation at break is low, the resin behaves as a rigid thermoset with limited plastic deformation; this distinguishes it from general-purpose resins that exhibit ductile yielding and from high-toughness resins that absorb impact through larger strain-to-failure.
Processing on stereolithography platforms such as 3D Systems Viper Si2 and iPro 8000 requires an elevated resin vat temperature to maintain viscosity within the recoater operating window. The material setup file controls laser power, scan speed, and layer thickness; a layer thickness of 0.1 mm is commonly used. Before build start, the resin must be gently stirred to remove settling because the formulation contains high-molecular-weight oligomers that can stratify during storage. In production, insufficient stirring can produce non-uniform crosslink density and lower the achieved heat deflection temperature in heavy sections. Vat temperature deviations below the specified setpoint can cause meniscus tearing, layer thickness variability, and increased resin adhesion to the recoater blade. Shops that process multiple Accura materials in shared vats must verify material identity and prevent cross-contamination, because residual general-purpose resin can lower the effective heat deflection temperature of a high-heat build and alter polymerization kinetics.
Thermal post-cure is not optional for Accura SL 5530. The build step alone produces a green-state part with incomplete crosslink density; the published 250–290 °C heat deflection temperature is achieved only after a controlled UV and thermal post-cure cycle. Residual cations continue to open epoxide groups during post-cure, increasing network density, shifting the glass transition to higher temperature, and reducing solvent uptake. The rate of this continuation is temperature-dependent: if the thermal ramp rate is too steep, the outside of the part crosslinks faster than the core, generating differential shrinkage and warpage. Because the material has an elongation at break of 1–2%, there is minimal plastic accommodation for thermal stress during this phase. Unsupported overhangs may distort if the part is not fixtured to avoid gravitational load during the low-modulus transient state at intermediate cure. Parts placed in a high-temperature oven without the manufacturer-defined staged thermal profile can exhibit lower ASTM D648 values, surface cracking in thin sections, and dimensional drift. The direction of post-cure also matters for large flat panels: supporting them on a flat plate can create a thermal gradient through the thickness, while vertical orientation can induce creep in the partially cured state. Published processing notes therefore specify a staged or ramped cycle, with the part supported to prevent sagging. After full post-cure, the part should be allowed to cool slowly to avoid thermal shock cracking.
Operational boundaries for Accura SL 5530 include low impact tolerance, limited elongation before fracture, and sensitivity to certain solvent-cleaning agents before full cure. Cleaning in isopropyl alcohol or manufacturer-approved solvents is standard, but prolonged immersion in aggressive ketone-based solvents can promote microcracking and should be avoided. The cured polymer absorbs atmospheric moisture over time; parts that will be exposed to high relative humidity or direct water contact may require sealing or coating. The material is not recommended for components that must withstand repeated snap-fit assembly, drop impact, or dynamic flexure because the low notched Izod values place it outside the design envelope served by high-toughness resins. Resistance to hydrocarbon-based fluids and elevated-temperature air is consistent with an epoxy-based thermoset, but chemical compatibility should be validated against the specific fluid mixture using ASTM D543 immersion protocols before production use. Thin wall sections can exhibit brittle fracture during support removal, so orientation and support strategy should avoid excessive post-build bending loads. The material is not a direct substitute for filled engineering polymers or metal inserts under high compressive or cyclic loading.
When compared with Accura SL 7800 and Accura SL 7840, the heat deflection temperature separates Accura SL 5530 from conventional SLA materials. Datasheet values for Accura SL 7800 list heat deflection temperature at 0.46 MPa near 48 °C per ASTM D648, and Accura SL 7840 near 49 °C at the same stress. Accura SL 5530 shifts the same measurement into the 250–290 °C band. That shift is achieved by sacrificing elongation: the general-purpose and tough materials typically show elongation at break in the 5–14% range, whereas Accura SL 5530 remains in the 1–2% range. The practical consequence is that Accura SL 5530 is selected for high-temperature tooling, test fixtures, and thermal exposure models, while Accura SL 7840 is selected where impact resistance and flexibility dominate. The selection is therefore not hierarchical but based on the required damage tolerance and thermal load.
| Comparison parameter | Accura SL 5530 | Accura SL 7800 | Accura SL 7840 |
|---|---|---|---|
| Heat deflection temperature, 0.46 MPa, ASTM D648 | 250–290 °C | 48 °C | 49 °C |
| Elongation at break, ASTM D638 | 1–2% | 5–14% | 5–12% |
| Typical design role | High-temperature rigid tooling and thermal fixtures | General-purpose form and fit models | Impact-loaded functional prototypes |
Accura SL 5530 is used in applications where the part must survive elevated temperature without losing shape. In short-run injection molding, stereolithography inserts have been used for low-pressure cavity testing with tool temperatures below the heat deflection threshold at the applied clamp pressure; inserts are typically backed or fitted into metal frames because the resin does not have the compressive strength of tool steel. In thermoforming tooling, the material provides a rigid, thermally stable surface for low-volume forming trials, but surface porosity and vacuum channel stress require evaluation. In aerodynamic test models, the combination of high heat deflection temperature and dimensional accuracy supports short-duration heated wind tunnel runs; however, published data for this specific configuration is limited, and each test article must be validated for stagnation temperature and dynamic pressure. In underhood automotive component fixtures, the material is used for thermal cycle and fit validation where the part is not load-bearing. The product also appears in investment casting pattern applications where high green-state accuracy is required; burnout characteristics should be confirmed for the specific shell process because the high crosslink density can retain ash or influence shell cracking.