    HS Code 465498
    Material Type Plastic
    Color Transparent/Translucent
    Density 1.13 g/cm³
    Tensile Strength 54 MPa
    Tensile Modulus 2370 MPa
    Elongation At Break 20%
    Flexural Strength 94 MPa
    Flexural Modulus 2400 MPa
    Notched Izod Impact 20 J/m
    Hardness 80 Shore D
    Heat Deflection Temperature 62 °C at 0.45 MPa
    Viscosity 200 cps at 30 °C
    Critical Exposure 10.7 mJ/cm²
    Penetration Depth 5.5 mils
    Water Absorption 0.35%
    Glass Transition Temperature 60 °C

    As an accredited 3D Systems Accura Sapphire Plastic for SLA Systems factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing
    Shipping
    Storage
    Free Quote

    Competitive 3D Systems Accura Sapphire Plastic for SLA Systems prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: admin@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The 3D Systems Accura Sapphire photopolymer for SLA Systems is supplied as a liquid resin formulated for solid-state stereolithography platforms operating at 355 nm, including the ProX 800 and ProJet 7000 series. The cured solid is a rigid, sapphire-blue transparent network with a polycarbonate-like balance of modulus and elongation; published datasheet values place the cured solid density at 1.17–1.18 g/cm³ and Shore D hardness at 83–85. The uncured resin viscosity is controlled within 180–220 cps at 30 °C, which permits recoat deposition on standard SLA blades without solvent dilution while maintaining adequate leveling in large-cross-section builds. Accura Sapphire is positioned as a moisture-resistant clear material for functional fluid-flow visualization, limited-run snap-fit assemblies, and transparent housings exposed to intermittent humidity. The material is not a low-viscosity general-purpose clear resin; its green-state handling strength and post-cure hardness are balanced for parts with wall thicknesses between 0.25 mm and 1.50 mm.

    What Differentiates Accura Sapphire from Accura 60, Xtreme, and ClearVue Resins?

    The principal difference between Accura Sapphire and Accura 60 is not the base modulus but the moisture-stable transparency envelope. Accura 60 is commonly selected for lens prototypes because of its optical clarity; Accura Sapphire is selected when a part must retain snap-fit engagement after 24 h water immersion at 23 °C. Against Accura Xtreme, the distinction is rigidity. Accura Sapphire tensile modulus is typically 2.4–2.6 GPa, whereas Accura Xtreme occupies a lower-modulus, higher-elongation ABS-like band near 1.8–2.0 GPa. Against Accura 25, Accura Sapphire is not a flexible polypropylene-like material; published elongation at break for Accura 25 is roughly two to three times that of Accura Sapphire. The table below summarizes the property envelope used for material substitution decisions.

    Published Typical Property Ranges for Accura Sapphire Cured by 355 nm SLA
    MeasurementValue RangeTest Standard
    Tensile strength at break48–52 MPaASTM D638-14 Type IV
    Tensile modulus2400–2620 MPaASTM D638-14
    Elongation at break8.4–12%ASTM D638-14
    Flexural strength72–84 MPaASTM D790-17
    Flexural modulus2200–2550 MPaASTM D790-17
    Notched Izod impact22–29 J/mASTM D256-10
    Heat deflection temperature at 0.455 MPa52–57 °CASTM D648-18
    Heat deflection temperature at 1.82 MPa47–51 °CASTM D648-18
    Shore D hardness83–85ASTM D2240
    Water absorption after 24 h immersion0.32–0.40%ASTM D570-98

    When the resin is imaged in a 3D Systems SLA vat, the absorbed dose at 355 nm determines both the working curve gelation point and the lateral overcure that closes clearances below 0.5 mm. A common production failure on galvo-scanned platforms is the accumulation of partially gelled resin in enclosed boss geometries, where the recoat blade cannot fully replenish liquid resin and the layer thickness deviates from the 0.100 mm nominal slice. Operators compensate by increasing edge scan exposure 10–15% relative to hatch scans and by adding vent slots of at least 1.5 mm diameter to trapped-volume bosses. Oxygen inhibition at the vat surface is lower than in some low-viscosity clear resins, but it is not absent. The resin requires a minimum layer thickness of 0.050 mm for reliable green-state stacking on ProJet 7000 HD; layers below this threshold are sensitive to under-cure and lateral tearing during recoater translation. Build chamber temperature drift beyond ±1 °C from the 30 °C setpoint raises viscosity sufficiently to alter the recoat film and produce layer-thickness bands on vertical walls.

    Large flat panels in Accura Sapphire have shown Z-axis curl when the recoater blade speed exceeds 250 mm/s on ProX 800 systems. The failure mode appears as out-of-plane distortion in thin wall sections below 1.0 mm and is traceable to residual tensile stress in the green state. Field data from production-scale builds indicate that rotating the part 30° to the recoater direction and reducing scan speed below 200 mm/s mitigates the distortion. Additional trapped resin in hollow channels is mitigated by printing drain holes of 2.0 mm diameter and by applying a 15 min drip period before part removal from the vat.

    Tensile Modulus, Flexural Strength, and Heat Deflection Data Under ASTM D638, D790, and D648

    Accura Sapphire mechanical response is orientation-dependent. Test coupons printed in the Z-direction show a reduction in tensile strength of 10–15% relative to the XY plane because of interlayer boundary stress concentrations. When conditioned at 23 ± 2 °C and 50 ± 5 % RH for 40 h before testing, XY-oriented Type IV specimens exhibit tensile strength in the 48–52 MPa range and tensile modulus of 2400–2620 MPa under ASTM D638-14. Cross-checks under ISO 527-2:2012 produce tensile modulus values within 3% of the ASTM dataset. Flexural strength measured by ASTM D790-17 on 3.2 mm thick specimens is 72–84 MPa, with flexural modulus of 2200–2550 MPa. The difference between tensile and flexural stiffness is within the expected range for a crosslinked photopolymer network and does not indicate a separate failure mode.

    Heat deflection temperature under 0.455 MPa is published at 52–57 °C; under 1.82 MPa the value falls to 47–51 °C per ASTM D648-18. These thresholds exclude Accura Sapphire from underhood thermal environments above 50 °C. For parts subjected to continuous load at 45 °C, creep is observed to increase with wall thickness below 2.0 mm; published long-term creep data for this specific configuration is limited. Impact strength under ASTM D256-10 is 22–29 J/m, which is sufficient for snap-fit engagement at room temperature but does not match the impact tolerance of Accura Xtreme in thick-section functional prototypes.

    Water absorption in cured Accura Sapphire is one of the primary selection parameters. After 24 h immersion at 23 °C, the weight gain is typically below 0.4% per ASTM D570-98. This is meaningful when snap-fit features are printed at 0.75 mm nominal thickness. In contrast to hygroscopic SLA materials that soften at high relative humidity, Accura Sapphire retains its Shore D hardness of 83–85 after 48 h at 90% RH, although dimensional growth of 0.1–0.2% has been reported in thin walls. This dimensional shift is sufficient to bind a 0.05 mm clearance hole, so designers are advised to maintain running clearances above 0.15 mm for humid service. The material should not be exposed to strong alkaline solutions above pH 10 for extended periods, as ester linkages in the network undergo hydrolytic degradation. Short-term contact with automotive coolant at 50 °C is processable, but continuous exposure to brake fluid is not recommended. The resin is supplied with REACH and RoHS 2011/65/EU compliance documentation; however, no food-contact claim should be inferred without a specific FDA 21 CFR migration study for the target geometry.

    When Post-Cure and Conditioning Protocols Deviate from the UVA/Thermal Reference Cycle

    Post-cure is not optional for Accura Sapphire. The manufacturer reference procedure specifies UV post-cure at 30–40 mW/cm² UVA irradiance for 60 min, followed by thermal conditioning at 40–50 °C for 2 h in a convection oven. Deviation from this cycle produces measurable property shifts. Undercured parts exhibit Shore D hardness up to 8 points lower and notched Izod impact values that can fall below 15 J/m. Overexposure to UVA does not increase hardness indefinitely; it accelerates yellowing in the sapphire-blue tint and can embrittle thin walls below 1.0 mm through additional crosslinking. In field builds on ProX 800 systems, overcure has been observed as edge curling in plates with aspect ratios above 6:1. The defect is controlled by rotating the part 30° to the recoater direction and reducing the post-cure UVA dose to 45 min for wall thicknesses below 1.0 mm. Parts requiring dimensional stability after humid exposure should be conditioned at 23 °C and 50% RH for a minimum of 24 h before final inspection.

    Accura Sapphire is therefore applied in fluidic manifolds, transparent snap-fit enclosures, and short-run optical housings where the combined requirements are moisture resistance, dimensional fidelity across 0.25–1.50 mm wall thickness, and a Shore D hardness above 80. It is not a substitute for high-temperature SLA resins such as Accura Peak or ceramic-filled Accura Bluestone when the operating environment exceeds 50 °C or when tensile modulus above 4 GPa is required.