|
HS Code |
265350 |
| Name | Spermidine |
| Chemical Formula | C7H19N3 |
| Molecular Weight | 145.25 g/mol |
| Cas Number | 124-20-9 |
| Appearance | White to off-white crystalline powder |
| Solubility | Soluble in water |
| Melting Point | 24–26 °C |
| Pubchem Cid | 1102 |
| Odor | Ammonia-like |
| Ph Value | 10.5 (1% solution in water) |
| Synonyms | N-(3-aminopropyl)butane-1,4-diamine |
| Storage Conditions | Store in a cool, dry place |
| Source | Naturally found in human tissues and various foods |
| Stability | Stable under normal temperatures and pressures |
| Use | Commonly used as a dietary supplement and laboratory reagent |
As an accredited Spermidine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Spermidine is packaged in a sealed amber glass bottle labeled "Spermidine, 1g," featuring hazard symbols and detailed handling instructions. |
| Shipping | Spermidine is shipped securely in tightly sealed containers, typically under inert gas or with desiccants to prevent moisture absorption. It is transported in compliance with chemical safety regulations, ensuring protection from heat, light, and contamination. Shipping documents include safety data sheets, and packaging is clearly labeled for identification and hazard information. |
| Storage | Spermidine should be stored in a tightly sealed container, protected from light and moisture. Keep the chemical in a cool, dry place, ideally at 2–8°C (refrigerated), unless otherwise specified by the manufacturer. Avoid exposure to strong oxidizing agents. Ensure that the storage area is well-ventilated and restrict access to authorized personnel to maintain safety and chemical integrity. |
|
Purity 99%: Spermidine Purity 99% is used in cell culture media supplementation, where it enhances cellular proliferation rates and viability. Molecular Weight 145.25 g/mol: Spermidine Molecular Weight 145.25 g/mol is used in autophagy research assays, where it promotes reliable induction of autophagic flux. Stability Temperature 4°C: Spermidine Stability Temperature 4°C is used in pharmaceutical formulation storage, where it ensures consistent compound integrity and shelf life. Particle Size <10 µm: Spermidine Particle Size <10 µm is used in encapsulation processes, where it achieves uniform particle dispersion and stable release profiles. Aqueous Solubility >1 g/L: Spermidine Aqueous Solubility >1 g/L is used in injectable solution preparations, where it facilitates rapid solubilization and homogeneous dosing. Melting Point 23–26°C: Spermidine Melting Point 23–26°C is used in temperature-sensitive synthesis protocols, where it offers predictable handling and material processing. Endotoxin Level <0.1 EU/mg: Spermidine Endotoxin Level <0.1 EU/mg is used in immunological studies, where it minimizes undesirable biological interferences. pH Stability Range 5.5–8.5: Spermidine pH Stability Range 5.5–8.5 is used in biochemical enzyme assays, where it maintains functional stability under assay conditions. UV Absorbance 260 nm: Spermidine UV Absorbance 260 nm is used in quantitative purity assessments, where it enables accurate detection and traceability. Heavy Metal Content <10 ppm: Spermidine Heavy Metal Content <10 ppm is used in nutraceutical product development, where it assures regulatory compliance and consumer safety. |
Competitive Spermidine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: admin@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As a chemical manufacturer with decades spinning out high-purity ingredients, I see interest in spermidine rising each year. Our own facilities have scaled production from kilogram lab runs to consistent metric ton batches, responding to both laboratory curiosity and industrial-scale demand. Spermidine’s unique structure—a polyamine with three amine groups—gives it more than a passing role in modern life sciences, plant research, and biochemical production. The product we supply, under designation SPD-HP98, holds a minimum assay of 98%. We track impurities—putrescine, spermine, and chloride ions—down to single-digit parts per million, keenly aware that downstream researchers and formulators expect more from the source than a simple white powder.
Working directly from raw materials through every purification step, we recognize the difference genuine process control makes. Each lot of spermidine draws inspection—not just for compliance, but to ensure each property meets the specs that real workflows demand. Color fluctuates with minor air exposure, so we monitor oxidation closely and double-vacuum seal our shipments. Residual solvents can threaten whole cell cultures, so we exchange solvents for water in the final stages and rigorously dry with nitrogen before packing. Our focus remains fixed on batch homogeneity, repeatability, and purity. That’s something a mere distributor rarely sees, but every experienced manufacturer knows well: waste even a point in quality, and costly reruns or research setbacks follow fast.
Some chemicals make their biggest impact only in massive quantities—fertilizers, industrial acids, feedstock amines. Spermidine sets itself apart for its precise influence in niches across cell biology, seed treatment, and enzyme stabilization. Many university groups order our SPD-HP98 in small lots to probe autophagy, aging, and cellular signaling, as peer-reviewed work shows spermidine can enhance cell homeostasis in model organisms. Farm researchers trial spermidine solutions to trigger seed germination and fight salinity stress in plants. Each application has little patience for technical foul-ups—the chemical must dissolve quickly, remain stable in solution, and show zero batch-to-batch surprises.
As a company, we pay close attention to the needs of molecular biologists and formulation chemists alike. Biological researchers often ask for documentation beyond the typical certificate of analysis. We go deeper, tracking enzyme inhibition results and documenting absence of heavy metals. For those blending spermidine into complex plant formulations, stability studies get carried out in various oils and seed extracts. No generic mix or single tool fits all jobs; we respond with technical advice, real-world stories from our QC team, and frequent test runs for new clients.
Polyamines cover a wide chemical family, and not all are equal at the bench. Spermidine stands between putrescine and spermine by chain length and bioactivity. Putrescine (a four-carbon diamine) enters most polyamine syntheses, but won’t substitute for the triamine character that gives spermidine its selective enzyme and DNA binding properties. Spermine, at four amines, disrupts plant cells at high concentration; spermidine supports controlled cell cycle effects at lower doses. Anyone who has swapped in a “close enough” polyamine finds this out fast: substitutions often block growth or fail to trigger expected cellular events.
Commercially, product grades matter as much as lineage. Some suppliers bottle raw-synthesized spermidine without pressing past the 95% mark. Our plant pushes for higher purity, relying on real-world controls—chromatographic stripping, not just acid washing. We keep a tight rein on temperature and pH at every stage, since even a few hours at 50°C can nudge side-chain oxidation and slowly dull performance in plant growth assays. Packaging isn’t a low-stakes afterthought either. By double-sealing under dry inert gas, and shipping quickly in temperature-controlled parcels, we protect the amine groups from environmental attack.
From the earliest syntheses, my team learned that spermidine’s sticky, hygroscopic nature tested every maintenance protocol. Once exposed to humid air, it clumps, browns, or degrades before analysts intervene. We run closed-system crystallizations and vacuum-dry with continuous moisture sensors. Even so, it takes a practiced eye to tell when a filter cake holds that signature feathery texture, rather than hinting at over-dried crystals—because too much drying rounds off the powder, reducing dispersibility in end-use solutions.
This practical attention to handling spills over into our storage and shipment cycles. Small manufacturing errors linger through assembly lines: residual iron from pumps, dust from workspaces, or unseen microbe growth in under-cleaned tanks have all spoiled batches in less-discerning plants. We run routine ICP-MS tests for metals and monitor total aerobic counts for every lot. Some of our longest-running pharmaceutical customers request direct audit trails back to raw materials, so we provide detailed run charts and batch numbers for full traceability.
Not every challenge comes from the chemical itself. Regulatory guidance, especially in Europe and North America, mandates rigorous recordkeeping, from shipping logs to purity metrics. Teams must log every step of synthesis and purification. We even maintain hour-by-hour temperature charts for each drying run, since any single deviation can compromise an entire shipment’s shelf life. These tight practices matter—customers regularly recount stories where supplier errors delayed trials or corrupted plant yield studies. We pride ourselves on not handing out apologies for breakdowns; instead, we share our procedural playbook with every prospective partner, ensuring our standards anchor trust right from the start.
One exciting shift of the last five years has seen a surge of demand from both plant and animal science. Collaborators in agricultural biotech tell us spermidine supports shoot elongation and improved salinity tolerance, fighting abiotic stress more reliably than older agents alone. Unlike generic biostimulants, spermidine enters plant cells with precision, nudging production of stress-mitigating enzymes without hammering growth controls. Researchers monitoring gene expression note upregulation of SOD, APX, and catalase—continuous signals that distinguish successful treatments. These nuances require not only a sharp chemical profile, but a transparent workflow right up to time of delivery.
Animal science and biomedical research add another layer of complexity. Demand for higher cell viability, cleaner metabolic profiling, and consistent study repeatability shapes our approach. Only top-grade polyamines show low enough endotoxin levels for delicate cell assays. To keep up, we run regular LAL tests for each new lot, backed by rapid-turnaround revalidation if required by our partners. The feedback loop is tight: if a university group flags a performance drop, we pull historical retention samples, rerun every standard, and report findings without delay. This responsiveness keeps research moving and saves costs for our clients, who would otherwise risk time-consuming troubleshooting.
Producing spermidine at factory scale means more than chemistry. We build skill through hands-on training: new analysts shadow experienced team members, learning how to spot contamination, smell off-odors, or track minute color shifts. In the face of rising raw material costs, we optimize reactor cleaning, solvent recycling, and heating cycles to trim unnecessary expenses without cutting any corner tied to product quality. Many improvements come from shop floor feedback; tech teams point out bottlenecks before control systems miss them. Sometimes, an old trick from a retired supervisor saves hours of rework or keeps a batch in spec.
These years in the trenches teach respect for customers’ real constraints. Large-scale buyers value our clean documentation and proactive shipping—months of planning hinge on every delivery. Research clients need assurance that the vial in their hands performs exactly as last year’s stock. We answer both by overlaying digital batch records with barcoded containers, rolling out online lot lookup, and packing each bottle to guard against light, moisture, or static. For emerging needs—injectable precursors, specialized buffers, or non-standard concentrations—we run short production pilots, supply detailed sample reports, and adapt fast to evolving industry benchmarks.
Sector focus shapes our manufacturing priorities over time, too. Where demand builds for food-grade or pharmaceutical compatibility, we expand high-pressure filtration capacity, sanitize every contact surface, and record every CIP cycle. We’ve opened our doors to annual GMP inspections, knowing that nothing short of stringent third-party oversight convinces partners in fast-regulating markets. Day by day, product reliability starts right on our plant floor, not in a distributor’s shipment truck.
Not all that carries a spermidine label reaches the same bar. Some market sources sell “food grade” or “compound grade” based on bulk-synthesis byproducts, skipping rigorous solvent removal and whole-batch chromatography. These shortcuts might work in simple fertilizer mixes but flounder under stricter research controls. We refuse “gray zone” intermediates; every single lot, whether kilogram or ton, follows the same GMP-rooted line, benefiting all clients from single lab vials to industrial tote containers.
Questions regularly arrive from partners burned by past suppliers: unexpected yellowing, inconsistent dissolution in buffers, or variable viscosity in seed treatment solutions. We hear these frustrations and trace them back to loose specifications, lazy handling, or cut corners in production steps. We do not take the easy path. Our commitment stays anchored in open communication, full COAs, and a promise that any drop below spec receives transparent explanation and rapid corrective action—rooted in firsthand manufacturing responsibility, not distribution chain blame-shifting.
All through this journey, openness with partners and research leads shapes quality. We supply reference documentation, keep technical teams available for direct Q&A, and maintain a rolling log of feedback to drive future improvements. In return, researchers share protocol tweaks, field notes on plant outcomes, or scientific questions that push our own understanding of what spermidine can unlock.
From synthesizing for farming groups curious about next-generation crop protection, to customizing cell culture reagents for biotechnology startups, our team embraces both routine and custom requests. Early engagement often reveals project-specific needs—tighter metal controls, adjusted pH profiles, or different counter-ions for formulation matching. We take these lessons into our continuous design process, never resting on published standards as the final word.
Industry also moves, demanding larger volumes, shorter lead times, and ever-better transparency. We invest in on-site analytical labs, automate data logging, and pursue certifications that go beyond what importers ask—knowing that future applications, from dietary supplements to agri-biotech, count on rock-solid upstream materials. Even as regulation grows tighter and expectations rise, our philosophy remains: make the product right, talk straight, and adapt to what customers actually experience on the ground.
Day after day, manufacture of spermidine requires more than technical know-how; it demands patient focus, problem-solving, and accountability at every step. Real-world experience built this process. Every employee—from operator to analyst—stands behind each vial we ship, knowing any compromise could set back a research advance, spoil a field test, or stall a manufacturing batch downstream. We see our job as amplifying the successes of those who rely on our ingredient: not merely shipping chemical, but pushing knowledge and partnership forward.
As applications broaden—from seed dormancy research to cell aging, enzyme stabilization, and specialized buffer preparation—expectations rise. We listen, run trials, discuss setbacks, and pursue solutions that move beyond what’s been done before. Our doors stay open to dialogue, whether sorting out a technical trouble or brainstorming a new method that needs test production. The future of spermidine rests in these shared efforts, honest reporting, and a history of getting it right when it matters most.