Products

Puffer Fish Extract

    • Product Name: Puffer Fish Extract
    • Alias: Tetraodotoxin
    • Einecs: 309-604-8
    • Mininmum Order: 1 g
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications

    HS Code

    576243

    Product Name Puffer Fish Extract
    Source Species Puffer fish (Tetraodontidae family)
    Primary Active Compound Tetrodotoxin
    Appearance Clear or slightly yellowish liquid
    Odor Mild fish-like smell
    Solubility Soluble in water
    Toxicity Level Highly toxic
    Common Uses Research, pharmaceutical studies
    Storage Conditions Refrigerate at 2-8°C
    Shelf Life 12-24 months (unopened)
    Packaging Form Sealed vial or ampoule
    Regulatory Status Controlled substance
    Extraction Method Solvent extraction
    Potential Hazards Neurotoxic, fatal if ingested
    Purity Level Typically >95%

    As an accredited Puffer Fish Extract factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Puffer Fish Extract: 10mL amber glass vial with tamper-evident seal, hazard labels, and bold warning text, shipped in insulated box.
    Shipping **Puffer Fish Extract** is classified as a hazardous material due to its high toxicity (contains tetrodotoxin). Shipping requires UN packaging, toxic substance labeling, and adherence to strict regulations (IATA, DOT). Only trained professionals should handle and transport it, accompanied by appropriate documentation and emergency response information. Ground or air shipment restrictions apply.
    Storage Puffer Fish Extract should be stored in a tightly sealed container, clearly labeled as toxic. Keep it in a dedicated, secure chemical storage area, away from incompatible substances and food. Maintain a cool, dry environment, out of direct sunlight. Access should be restricted to authorized personnel only, following all applicable safety regulations for handling potent biological toxins.
    Application of Puffer Fish Extract

    Purity 98%: Puffer Fish Extract with 98% purity is used in pharmaceutical research, where enhanced consistency in bioactive compound delivery improves trial reproducibility.

    Molecular Weight 35 kDa: Puffer Fish Extract at 35 kDa molecular weight is used in neurotoxin screening assays, where precise molecular profiling facilitates detection sensitivity.

    Stability Temperature 4°C: Puffer Fish Extract stable at 4°C is used in cold-chain biochemical storage, where extended shelf life ensures reliable experimental results.

    Toxin Content <1 ppm: Puffer Fish Extract with toxin content less than 1 ppm is used in cosmetic safety testing, where minimized toxicity enables safer formulation evaluation.

    Water Solubility 100 mg/mL: Puffer Fish Extract with 100 mg/mL water solubility is used in injectable drug development, where ease of formulation increases bioavailability.

    pH Range 6.5–7.5: Puffer Fish Extract within pH 6.5–7.5 is used in in vitro neuronal assays, where compatibility with cell culture conditions promotes cell viability.

    Endotoxin Level <0.05 EU/mg: Puffer Fish Extract with endotoxin level under 0.05 EU/mg is used in sterile pharmaceutical manufacturing, where low endotoxin contamination reduces immunogenic risk.

    Melting Point 60°C: Puffer Fish Extract with a 60°C melting point is used in thermal stability testing, where resistance to degradation at elevated temperatures maintains functional integrity.

    Particle Size <5 µm: Puffer Fish Extract with particle size under 5 µm is used in topical delivery systems, where fine dispersion optimizes skin absorption rate.

    Protein Content 95%: Puffer Fish Extract containing 95% protein is used in nutraceutical formulation, where high protein concentration supports functional food development.

    Free Quote

    Competitive Puffer Fish Extract prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Puffer Fish Extract: Real Benefits From Our Hands-On Manufacturing

    Introduction to Puffer Fish Extract

    After years of working closely with marine bio-compounds, our facility developed Puffer Fish Extract with a practical focus on purity and consistency. We have watched the global market for marine-derived products shift toward specialty applications, largely led by unique bioactive compounds like tetrodotoxin found in puffer fish. Our extract goes through a rigorous clarification and fractionation process on-site, where our chemists take direct charge of every critical step. Each lot starts with wild-caught puffer fish, checked in-house for quality indices and correct species identification, instead of relying on spot-checks from distant brokers. Working at this scale offers a perspective on contaminants, batch variations, and the right temperatures for stability, which laboratory-scale suppliers seldom match.

    Model and Specifications

    We manufacture our Puffer Fish Extract in an aqueous form, model AE-PFX-10, built for research environments, pharmaceutical work, and reference use for safety testing. Concentration and solvent profiles are tuned based on feedback from toxicology teams and pharmacologists in both clinical research and material validation labs.

    Purity forms the cornerstone of our product. Most commercial batches reach 98%+ tetrodotoxin content by HPLC, with no added preservatives or fillers. Our technical staff manages all filtration, fractionation, and lyophilization on-site, so changes in extraction efficiency can be directly monitored and corrected. This gives our extract sharper reproducibility during bioassays and standardization work. The solvent system remains water-based, buffered to near-neutral pH to prevent hydrolysis or by-product formation. Vial sizes typically range from 5 mL up to 100 mL, with custom fill-volumes supported for controlled testing projects.

    Batch history records and in-process checks help minimize risk of cross-species misidentification, which can otherwise introduce dangerous impurities. Instead of waiting days for outsourced lab results, our technical team works shoulder-to-shoulder with chemists for same-day tracking of purity, salinity, and presence of co-extracted fats or peptides.

    Core Usage: Genuine Laboratory and Research Practice

    Pharmacologists and neurobiology teams have leaned on our Puffer Fish Extract for nerve conduction and sodium channel studies, in vitro toxicology work, and design of detection assays. Rather than focusing only on the final result, our production emphasizes the actual experience researchers encounter with each vial. Extraction protocols and protocols for dilution go out with every batch, not as afterthoughts but as an integral bridge between producer and end-user.

    One major concern among our clients relates to reliability. In academic settings, one failed batch can derail months of painstaking work or skew clinical baseline readings. Our track record on repeat orders shows users value not only potency, but the transparency and clarity in production methods and traceability. Consulting with regulatory advisors, we stay up-to-date with country-specific controls on marine toxins and biosafety, so our clients never face last-minute compliance issues. Our facility keeps comprehensive logs for every shipment, including documentation for customs and transport—a necessity for research teams with international projects or import hurdles.

    The use of puffer fish tetrodotoxin is highly regulated due to its extreme potency. Our own experience in handling, storage, and stability studies proved that not all extracts tolerate temperature changes or repeated pipetting equally. That hard-won knowledge has shaped our final buffer choice and standards for packaging—double-sealed, shock-resistant vials paired with custom absorptive liners. These details have often prevented loss during long courier routes or delays at customs, which no stock off-the-shelf packaging could address.

    Differences From Other Marine Extracts

    Some companies offer crude marine extracts with uncharacterized toxin content, but purity and specificity vary sharply with their supply chain approach. Others focus on lower-cost processes—bulk-filtering and stocking freeze-dried powder—but that frequently introduces unwanted organic debris. We prefer direct, vertically-coordinated sourcing, controlled extraction, and post-process purification, so our product stands apart on batch-to-batch consistency.

    For teams requiring certified reference material, our closely monitored fractionation and documentation exceed the practices of most resellers or generic biochemical suppliers. Choice of wild-caught source fish, intentional avoidance of bulk brokers, and absolute commitment to in-house analytical control underpin every batch. Our large-scale operation means we experience challenges small-batch extractors never see: shipment interruptions, customs seizures, biohazard protocols, and environmental temperature swings. We have shaped our extraction and packaging for these issues to guarantee that research isn’t left waiting or left questioning the contents of any shipment.

    Other marine sources might contain similar neurotoxins, for instance blue-ringed octopus or certain gastropods, but the principal active component and associated by-products differ in purity and action. Several large labs have switched away from multi-source products due to the risk of non-tetrodotoxin neuroactives appearing in bioassay results. Mixing toxins can blur results for teams mapping sodium channel inhibition against reference standards. Our extract draws a clear line between true tetrodotoxin and unrelated neuroactives, using repeated mass spectrometry screens to rule out variant analogs.

    Safety, Handling, and Real-World Manufacturing Lessons

    Working with puffer fish extract involves risk. As a manufacturing team, we were forced through various iterations of facility upgrades before our own safety procedures stood up to real-world tests. Automated air monitoring, glove box transfer, negative pressure rooms, and daily spill drills have become the backbone of our workflow. These aren’t just checkboxes for compliance—they are genuine solutions to the problems every marine toxin manufacturer faces: vapors, inhalation, and accidental dermal contact. Handling mistakes have real consequences, and every protocol evolved directly from hard lessons in early production runs.

    On the shipping side, tight temperature control matters because tetrodotoxin’s lability is unforgiving at high or unstable temperatures. Early failures in our logistics pipeline led us to develop proprietary packaging engineered in tandem with specialty couriers, and maintain chain-of-custody documentation that tracks every case on its real-time journey to the end-user.

    The legal landscape puts unique responsibilities on manufacturers. Apart from navigating export controls, accurately characterizing and labeling every batch ensures research isn’t compromised by customs or regulatory delays or sudden product recalls. Real discussion with regulatory inspectors guided us in writing our labeling, rather than copying generic documentation from unrelated products. That input has reduced shipping holdups and cut down audit time for customers, especially university procurement offices and state agencies.

    What Sets Our Extract Apart in Long-Term Use

    Our team’s understanding of puffer fish biochemistry comes from repeated, direct extraction and close monitoring, not theoretical textbook knowledge. Long before international regulations tightened, we saw the impact careless handling can have: lost shipments, questionable results, and safety scares. That experience led us to set higher internal standards for solvent purity, batch documentation, and client transparency, all informed by the real questions and problems raised by toxicologists and biosafety managers.

    Some marine extracts receive only cursory screening for contaminants, but our process uses multiple rounds of liquid chromatography plus mass spectrometry specifically for batch release. This depth yields a product proven to be reliable in both endpoint and kinetic assays, even when scaled up for multi-center studies or sent to new countries with different baseline controls.

    Many years in this industry taught us that price pressure should not dictate the shortcuts taken in extraction or purification. Those choices show up directly in product stability, ease of use, and less obvious—long-term user trust. We built a robust internal reporting and traceability loop spanning raw fish receipt, extraction, QA, and final shipment, so our clients have direct insight into what arrives in each vial. If changes occur in procedure or material source, clients receive an advance notice; our approach does not hide technical shifts behind undated “updates” or general supplier language.

    Closing Insights on Puffer Fish Extract Manufacturing

    Staying ahead in marine-derived bioactive manufacturing means constant adaptation to both regulatory and practical hurdles. Our difference stems from having skin in the game through every real-world problem: interrupted marine harvesting due to weather, evolving standards for biosafety, and shipping chaos during political or logistical disruptions. Each one forces manufacturers to refine extraction steps, storage protocols, and document practices, which then benefit the entire research pipeline.

    We continually invest in the direct training of our staff, not just on compliance, but on technical trouble-shooting and process improvement. Our chemists, extraction specialists, and logistics managers work in synergy to resolve bottlenecks and develop rapid solutions, making production resilient to challenges that sink less coordinated producers. Our standards for traceability and support reflect those real client questions that arise during multi-year research projects, where one off-batch or uninterpreted anomaly can set back critical findings.

    Puffer Fish Extract has earned its place—and heavy regulation—through both its research value and its hazards. Only a manufacturing team steeped in its day-to-day realities knows how those risks are best managed from dock and lab to user hands. We believe open processes, real-time problem solving, and clean communication with users drive a product that can be trusted far beyond generic alternatives. Each lot stands as a reflection of the daily, sometimes difficult, choices that experienced chemical manufacturers make to deliver true reliability and scientific value to the field.

    Top