| HS Code | 718194 |
| Productname | Sevoflurane Inhalation Anesthetic Pharma Grade API |
| Inn | Sevoflurane |
| Casnumber | 28523-86-6 |
| Atccode | N01AB08 |
| Unii | 38LVP0K73A |
| Molecularformula | C4H3F7O |
| Molecularweight | 200.055 g/mol |
| Iupacname | 1,1,1,3,3,3-hexafluoro-2-(fluoromethoxy)propane |
| Appearance | Clear, colorless, volatile liquid |
| Odor | Sweet, ethereal, nonirritating |
| Boilingpoint | 58.6 °C |
| Meltingpoint | -118 °C |
| Density | 1.520 g/mL at 25 °C |
| Refractiveindex | 1.2745 at 20 °C |
| Vaporpressure | 157 mmHg at 20 °C |
| Solubility | Slightly soluble in water; miscible with organic solvents |
| Grade | Pharma Grade / API |
| Purity | ≥99.9% |
| Pharmacopeia | USP, EP, JP, BP |
| Storageconditions | Store at 15-30 °C; protect from light; keep container tightly closed |
| Routeofadministration | Inhalation |
| Therapeuticcategory | Inhalation general anesthetic |
| Flammability | Nonflammable |
| Chemicalstability | Stable under recommended storage conditions; avoid strong oxidizing agents |
| Packaging | Amber glass or aluminum containers; 250 mL, 1 L, or bulk API drums |
As an accredited Sevoflurane Inhalation Anesthetic Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sevoflurane Inhalation Anesthetic Pharma Grade API, 250 mL amber glass bottle, sealed for tablet/capsule/granule/injection and oral/injectable use. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): Sevoflurane Inhalation Anesthetic Pharma Grade API for tablet/capsule/granule/injection, oral/injectable; securely palletized drums, sealed, labeled, temperature-controlled. |
| Shipping | Sevoflurane API ships in sealed, UN-approved, leakproof containers under ambient conditions, protected from light, heat, moisture, and ignition sources. Transport follows IATA/ADR/IMDG and GDP rules, with SDS, COA, batch records, and hazard labeling. Temperature monitoring is available for oral/injectable pharma-grade consignments. |
| Storage | Store Sevoflurane Inhalation Anesthetic Pharma Grade API in a cool, dry, well-ventilated, secure area, away from heat, ignition sources, and direct sunlight. Keep containers tightly closed, upright, and clearly labeled. Protect from moisture, contamination, and incompatible oxidizers. Maintain controlled access, segregate from food/feed, and comply with GMP/local regulations. Store at controlled room temperature unless otherwise specified. Follow manufacturer instructions. |
| Shelf Life | Typically 24–36 months when stored tightly sealed, protected from light, at controlled room temperature, away from moisture and heat. |
The principal industrial use of pharma-grade sevoflurane is as a volatile liquid API filled into sealed containers for hospital anesthesia workstations. The terminal output is a 100% v/v sevoflurane inhalation liquid, dispensed from a temperature-compensated bypass vaporizer. Filling lines for the finished drug product use nitrogen blanketing and sealed stainless-steel transfer lines. Bulk liquid is maintained below 58.5 °C to reduce evaporative loss. At 20 °C, the vapor pressure is approximately 157 mmHg. The saturated vapor concentration at 760 mmHg is therefore 20.7% v/v. Adult maintenance dial settings usually fall between 2% and 3% in oxygen or oxygen/nitrous oxide.
Low-flow and closed-circuit anesthesia reduces fresh gas flow below 1–2 L/min to conserve agent and retain airway humidity. This process requires continuous monitoring of inspired and expired sevoflurane, oxygen, carbon dioxide, and airway pressure through an infrared or photoacoustic multigas analyzer. The anesthesia workstation is supplied to ISO 80601-2-13:2011. The critical boundary condition is the reaction between sevoflurane and carbon dioxide absorbents such as soda lime or barium hydroxide lime. The reaction produces fluoromethyl 2,2-difluoro-1-(trifluoromethyl) vinyl ether, commonly called Compound A. Formation increases at low fresh gas flow, high absorber temperature, high agent concentration, prolonged exposure, and desiccated absorbent beds. Desiccated absorbent beds can also generate exothermic temperature excursions when exposed to sevoflurane-saturated gas. API specification control therefore covers low-moisture packaging, absence of nonvolatile residue, and residual solvents under USP <467>. Finished product labeling carries flow-rate and absorbent cautions. Production-scale packaging uses gravimetric fillers, inert blanketing, closure torque monitoring, and controlled room-temperature storage. Published label guidance for Compound A management recommends minimum fresh gas flow rates and replacement of desiccated absorbent; specific exposure thresholds vary by jurisdiction and absorbent formulation.
In pediatric practice sevoflurane is used for mask induction because its blood-gas partition coefficient of 0.65–0.69 permits rapid equilibration, and it produces less airway irritation than isoflurane. The vaporizer is commonly set to 8% in oxygen or an oxygen/nitrous oxide mixture during inhalational induction. The 8% setting is the maximum dial position on most commercial sevoflurane vaporizers. Delivered concentration is modified by carrier gas viscosity, backpressure, respiratory rate, and fresh gas flow. High fresh gas flows of 6–10 L/min are used to prime the circuit before mask application. Active scavenging is required. The terminal product is the same undiluted 100% v/v sevoflurane inhalation liquid; no pediatric-specific formulation is used.
| Population | MAC | Reference condition |
|---|---|---|
| Adult human | 2.0% | Normobaric oxygen |
| Elderly human | 1.5% | Age above 65 years |
| Neonate | 3.3% | 0–30 days |
| Infant | 3.0% | 1–6 months |
| Child | 2.5% | 6 months–12 years |
Manufacturing control for this application is tied to vaporizer precision and API purity rather than dosage form modification. At 760 mmHg, an 8% vaporizer output equals a partial pressure of 60.8 mmHg. At 650 mmHg, the same volume percent equals 52 mmHg. High-altitude procedures may require a higher dial setting to achieve the same clinical partial pressure. ICH Q3C residual solvent compliance is material because any nonvolatile impurity remains in the vaporization chamber and may accumulate on the sintered wick after repeated filling. Particulate matter control and water content are monitored. Production-scale filling lines verify drop-tested closure integrity and evaporative loss under simulated distribution.
Small-animal veterinary anesthesia relies on sevoflurane metered through out-of-circuit precision vaporizers at oxygen flow rates from 0.5 L/min to 3 L/min. The API supplied to veterinary compounding distributors is the same pharmacopeial liquid as the human product. The terminal product remains a 100% v/v inhalation liquid. A typical procedure includes preoxygenation, injectable induction, endotracheal intubation, and maintenance at 2.5% to 3.5% delivered concentration in oxygen. Published MAC values for dogs, cats, and horses are approximately 2.4%, 2.6%, and 2.3%, respectively. These values shift with age, hypothermia, opioid coadministration, and nitrous oxide use. Veterinary anesthesia machines are often adapted from human workstations but may lack automated agent analyzers; manual vaporizer dial verification and oxygen flow calibration are required before each procedure. Scavenging is required because expired sevoflurane in poorly ventilated procedures can exceed occupational exposure limits. Distribution for veterinary use is governed by national veterinary-medicine law. In the United States, extralabel use of a human-approved drug in companion animals may occur under 21 CFR 530. Published data for food-producing species are limited; use is generally confined to companion animals. No oral tablet, capsule, granule, or injectable sevoflurane product is used in veterinary medicine. Attempted dilution into aqueous injectable vehicles fails because phase separation occurs and gas formation can follow at body temperature.
When pharma-grade sevoflurane is used to generate a calibration gas stream, the terminal output is a traceable gas mixture rather than a drug product. The liquid is injected into a temperature-controlled vaporization cell or dynamic saturation bubbler and mixed with medical air, oxygen, or nitrogen at total flow rates from 0.5 L/min to 5 L/min. The critical variable is saturated vapor concentration. At 20 °C and 760 mmHg, the theoretical saturated output is 20.7% v/v. Dilution with mass-flow-controlled carrier gas produces lower test points, typically 1%, 3%, and 6%. Analyzer accuracy is evaluated according to ISO 80601-2-55:2011, which sets performance requirements for respiratory gas monitors. Gas is directed through a Nafion or water trap before the analyzer inlet to prevent humidity interference.
Carrier gas substitution changes analyzer response more than the actual sevoflurane concentration. Infrared analyzers rely on absorption spectra, and nitrous oxide can shift or overlap absorbance bands in some multigas monitors. Verification procedures therefore record carrier gas composition and barometric pressure. At 650 mmHg, a saturated sevoflurane stream remains at the same partial pressure, but the volume percent increases to 24.2%. That distinction confirms whether the monitor is reporting partial pressure or volume percent. Production-scale calibration facilities use pressurised liquid filling systems and sealed reference cylinders. Published data for long-term stability of sevoflurane in cylinders at concentrations above 10% are limited because polar surfaces and polymer seals can adsorb the agent. Stainless-steel or glass contact materials, PTFE-lined closures, and periodic gravimetric verification are therefore standard.
Gas chromatographic assay of sevoflurane drug substance and finished liquid product is performed against a compendial reference standard using a nonpolar bonded-phase capillary column and flame ionization detection. The terminal product in this segment is a reference standard lot or system suitability solution, not a dosage form. Incoming API is sampled through a closed stainless-steel or glass sampling loop to limit evaporative loss. Bulk sealed containers are stored at controlled room temperature; prepared diluted standards are stored at 2–8 °C. The API boils at 58.5 °C, so syringe transfer at room temperature can vary by several percent if headspace is not accounted for. Chromatography system suitability follows USP <621> and Ph. Eur. 2.2.28. Residual solvent testing under USP <467> and ICH Q3C is performed because sealed glass containers can retain synthetic-route impurities that would not be removed by evaporation. Degradation profiling in absorbent exposure studies uses complementary gas chromatography with headspace sampling. Published data for some degradation product configurations are limited when nonvolatile absorbent residues concentrate during low-flow closed-circuit exposure. Production quality control also measures water content and nonvolatile residue because both affect vaporizer performance and long-term storage stability. Regular injection port liner replacement and column head pressure verification are necessary when assaying undiluted sevoflurane due to its high vapor volume.
Direct substitution of sevoflurane into oral or parenteral dosage forms is not supported by current physicochemical data. The API boils at 58.5 °C and has a vapour pressure of approximately 157 mmHg at 20 °C. A tablet or capsule granulation process operating at conventional wet granulation drying temperatures of 50–60 °C would partially or completely evaporate the API. Even direct compression or roller compaction at ambient temperature produces localized die and roller heating. The finished matrix does not seal the volatile liquid unless a complex barrier coating is used. Capsule shells may soften or deform when filled with a liquid that develops high internal vapor pressure at storage temperatures. If granulation is attempted, solvent-assisted or melt granulation below 20 °C would be required, and published data for stable oral solid sevoflurane release profiles are limited. The compound is not recognized in current USP or Ph. Eur. monographs as an oral solid or oral liquid API.
Injectable development fails for different reasons. Sevoflurane has low water miscibility, and an aqueous parenteral vehicle would phase-separate on standing. After injection, the high vapor pressure would promote gas evolution at body temperature. The blood-gas partition coefficient of 0.65–0.69 means the compound is rapidly eliminated by the lungs during first pass. Systemic exposure would depend on ventilation and cardiac output rather than first-order hepatic clearance. A parenteral emulsion could theoretically modulate release, but no approved product, no validated pharmacokinetic model, and no compendial monograph exist for this configuration. Published data for this specific configuration are limited. Therefore, a pharmaceutical API datasheet that lists tablet, capsule, granule, or injection under dosage forms should not be interpreted as a validated downstream segment for sevoflurane. The only recognized route is inhalation, with the API supplied as a liquid for vaporizer delivery.
Competitive Sevoflurane Inhalation Anesthetic Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Where a volatile liquid active pharmaceutical ingredient is specified for inhalation anesthetic delivery, the product is received as sevoflurane inhalation anesthetic pharma grade API, chemical name 1,1,1,3,3,3-hexafluoro-2-(fluoromethoxy)propane, molecular formula C4H3F7O, molecular weight 200.055 g/mol, CAS 28523-86-6. The model designation referenced in this profile is SEV-PG-100, covering the inhalation-grade liquid packaged in 250 mL, 500 mL, and 1 L fluorinated high-density polyethylene containers under inert gas. The product is described in the title as suitable for tablet, capsule, granule, injection, oral, and injectable use; however, sevoflurane boiling point of 58.5 °C and vapor pressure of approximately 157 mmHg at 20 °C impose restrictions on conventional solid oral and aqueous injectable unit operations. Pharmacopeial status is defined by USP and Ph. Eur. monographs for sevoflurane. Manufacture is expected to follow ICH Q7 GMP for active pharmaceutical ingredients, with finished container-closure systems evaluated according to FDA 21 CFR 211.94 and USP <661.1>.
Conformity is assessed for identification, assay, related compounds, acidity, water content, fluoride, nonvolatile residue, and residual solvents. The liquid is expected to be clear and colorless, with a characteristic ether odour; visible particulate matter is not acceptable. Gas chromatographic assay is performed against a sevoflurane reference standard. Certificates of analysis for SEV-PG-100 normally report assay by area normalization between 99.9% and 100.0% when filled under nitrogen. Water content is limited to ≤ 0.05% w/w by coulometric Karl Fischer titration, because water promotes hydrofluoric acid formation and corrosion of vaporizer internals. Related compounds are controlled by low-bleed capillary GC with flame ionization detection; residual hexafluoroisopropanol and other fluorinated process impurities are typical monitored features. Total related compounds are commonly limited to ≤ 0.1%. Acidity is expressed as hydrofluoric acid and is maintained at a monograph-defined low limit. Nonvolatile residue is limited to ≤ 0.005% w/w to prevent deposition in precision vaporizer bypass channels.
| Quality attribute | Control basis | Representative limit / method |
|---|---|---|
| Identification | USP/Ph. Eur. monograph | IR or retention time match to reference standard |
| Assay by GC | Gas chromatography area normalization | ≥ 99.0% to 100.0% |
| Water | Coulometric Karl Fischer titration | ≤ 0.05% w/w |
| Related compounds total | Low-bleed capillary GC/FID | ≤ 0.1% |
| Acidity as HF | Monograph titration | Monograph-defined low limit |
| Nonvolatile residue | Evaporation | ≤ 0.005% w/w |
| Residual solvents | USP <467>, ICH Q3C | Class 1, Class 2, Class 3 options applied |
| Elemental impurities | ICH Q3D | Route-appropriate permitted daily exposure |
Batch release also requires residual solvent analysis by headspace gas chromatography according to USP <467> and ICH Q3C; for inhalation APIs, the risk assessment normally applies Option 1 or Option 2 of the guideline. Elemental impurities are assessed by inductively coupled plasma mass spectrometry according to ICH Q3D, with the permitted daily exposure selected by the route of the finished drug product. Sevoflurane is not supplied as a sterile product, but microbial and endotoxin limits are set by the downstream finished drug manufacturer where injectable presentations are proposed.
The solid oral and injectable designations in the product title require interpretation against the API volatility and absence of pharmacopeial drug product monographs. A boiling point of 58.5 °C and a vapor pressure of 157 mmHg at 20 °C mean that conventional tablet or capsule granulation at elevated bed temperatures would cause API loss. Fluid-bed granulation, tray drying, and direct compression powder handling would require sealed sub-ambient equipment with solvent recovery or vapour capture. To formulate SEV-PG-100 into a tablet or capsule, the API would need to be adsorbed or complexed with a high-surface-area carrier under sub-ambient conditions; direct compression would require humidity below 30% RH and closed punch-and-die assemblies. For injection, sevoflurane has limited aqueous miscibility; aqueous formulations would require cosolvents, cyclodextrins, or lipid emulsions, and no monograph or approved formulation exists for this route. Published data for tablet, capsule, granule, injection, oral, and injectable configurations is limited. The SEV-PG-100 model is therefore supplied for inhalation anesthetic formulation; non-inhalation applications must be treated as investigational and justified by closed-system handling and stability data generated under ICH Q1A(R2) conditions.
Sevoflurane has a higher boiling point than desflurane (23.5 °C) and is less volatile, allowing conventional variable-bypass vaporizers to operate over a 10–40 °C ambient range without the pressurised heated vaporizer required for desflurane. The blood/gas partition coefficient of sevoflurane is 0.65, between desflurane 0.42 and isoflurane 1.4; this produces rapid mask induction but slower uptake than desflurane. The MAC in oxygen for sevoflurane is approximately 2.05% in adults at 37 °C and 1 atm, compared with 6.0% for desflurane, 1.15% for isoflurane, and 0.75% for halothane. Sevoflurane is nonpungent at inspired concentrations used for inhalation induction, while desflurane and isoflurane are associated with airway irritation. These differences affect vaporizer design, filling line temperature control, and finished product labelling for use in structurally dry anesthesia circuits.
Metabolism also distinguishes sevoflurane from older agents. Sevoflurane undergoes approximately 5% metabolic degradation to hexafluoroisopropanol and inorganic fluoride, whereas halothane undergoes 20–45% oxidative metabolism. Desflurane metabolism is 0.02%; isoflurane metabolism is 0.2%. This metabolic profile contributes to the lower hepatic burden of sevoflurane relative to halothane and is used in product risk assessments for chronic or repeat exposure. In carbon dioxide absorbents, sevoflurane degradation to Compound A is influenced by absorbent temperature, absorbent moisture, and fresh gas flow; desflurane and isoflurane can generate carbon monoxide in desiccated strong-base absorbents. These stability differences require separate handling pathways in anesthesia machine maintenance.
| Parameter | Sevoflurane | Desflurane | Isoflurane | Halothane |
|---|---|---|---|---|
| Boiling point | 58.5 °C | 23.5 °C | 49 °C | 50.2 °C |
| Blood/gas partition coefficient | 0.65 | 0.42 | 1.4 | 2.4 |
| MAC in oxygen | 2.05% | 6.0% | 1.15% | 0.75% |
| Vaporizer requirement | Conventional variable-bypass | Heated pressurised for stable delivery | Conventional variable-bypass | Conventional variable-bypass |
| Airway pungency | Low; suitable for mask induction | Higher; generally not used for mask induction | Higher; can irritate | Intermediate to low; used historically |
Transfer operations for SEV-PG-100 are performed under nitrogen or dry air to exclude moisture. Product-contact surfaces are passivated stainless steel or fluoropolymer-lined equipment; elastomeric seals are selected from fluoropolymer grades to limit extractables. The filling suite is maintained at positive pressure with relative humidity below 30% RH and temperature below 25 °C. Each container is purged, filled, closed with an induction-sealed polypropylene closure, and leak tested according to USP <1207> or equivalent. Batch records capture fill volume, headspace oxygen, moisture, and container closure integrity. These controls are intended to keep water below 0.05% w/w and to limit occupational exposure to the applicable national threshold limit for volatile anesthetic agents. The API must not be exposed to desiccated soda lime or Baralyme during handling because degradation to Compound A, fluoromethyl-2,2-difluoro-1-(trifluoromethyl) vinyl ether, increases at low absorbent moisture and high temperature. This incompatibility is an operational boundary of the inhalation delivery system rather than a batch release specification.
Validation of the filling line for SEV-PG-100 includes three consecutive process qualification batches. Fill volume is monitored by gravimetric checkweighing with accuracy ± 1.0% of target; headspace oxygen is kept below 2.0% v/v; and moisture in the headspace is kept below the method detection limit. Container closure integrity testing is performed by vacuum decay or dye ingress. These process controls are manufacturer-specific but align with ICH Q7 and current GMP expectations for volatile API packaging.
Given the absence of published stability data for sevoflurane in tablet, capsule, granule, injection, oral, or injectable finished products, formulators using the SEV-PG-100 model for these routes should regard the dosage form as investigational. Any claims for those presentations require compatibility screening under ICH Q1A(R2), container-closure evaluation per USP <1664> or USP <661.1>, and method validation according to ICH Q2(R2). Without such data, the API is limited to its established inhaled anesthetic application. The active pharmaceutical ingredient is not supplied with preservatives, buffering agents, or formulation excipients, and is not intended for direct administration before vaporization or formulation by a licensed pharmaceutical manufacturer.