| HS Code | 657839 |
| Product Name | PVC MONO Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Material | Polyvinyl chloride (PVC) |
| Grade | Pharma Grade |
| Product Type | Monolayer PVC film |
| Primary Application | Pharmaceutical packaging and blister packaging |
| Dosage Form Compatibility | Tablet, Capsule, Granule, Injection, Oral, Injectable |
| Route Of Administration | Oral and Injectable |
| Physical Form | Film / Roll |
| Color | Clear / Transparent |
| Thickness Range | 0.20 mm to 0.50 mm |
| Density | 1.35 to 1.45 g/cm³ |
| Tensile Strength | ≥ 50 MPa |
| Elongation At Break | ≥ 200% |
| Water Vapor Transmission Rate | Low |
| Oxygen Barrier | Moderate |
| Thermoforming Temperature | 100°C to 140°C |
| Regulatory Compliance | USP Class VI, ISO 9001, GMP |
| Sterilization Compatibility | Gamma irradiation, Ethylene oxide |
| Storage Conditions | Dry, cool, away from direct sunlight |
| Packaging Format | Rolls |
| Shelf Life | 24 months |
As an accredited PVC MONO Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 25 kg net weight, double polyethylene-lined fiber drums, sealed and labeled for pharmaceutical oral and injectable use. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): loaded with PVC MONO Pharma Grade API, suitable for tablet, capsule, granule, oral, and injectable use. |
| Shipping | PVC MONO Pharma Grade API shipped in sealed, tamper-evident, pharma-grade containers under controlled temperature, protected from light, moisture, and contamination. Compliant with GDP and IATA/ADR/IMDG regulations. Each batch includes CoA, SDS, and documentation. Suitable for oral and injectable applications; maintain chain of custody and quarantine until receipt. Store per label. |
| Storage | Store PVC MONO Pharma Grade API in original, tightly sealed containers in a cool, dry, well-ventilated area, protected from sunlight, moisture, and heat. Maintain controlled room temperature (15–25°C/59–77°F). Keep away from oxidizing agents, ignition sources, and contamination. For oral and injectable use, follow cGMP segregation and store under hygienic, validated conditions. |
| Shelf Life | PVC MONO Pharma Grade API: typically 24–60 months in sealed containers, protected from moisture, light, heat; confirm via manufacturer stability data. |
Thermoformed blister cavities for immediate-release tablet and hard capsule formats are converted from 200–400 µm non-plasticised PVC MONO sheet on flat-bed or rotary blister lines. The PVC MONO pharma grade is formulated without monomeric plasticisers and is stabilised with calcium-zinc chemistry at 0.5–1.5 phr to satisfy the extraction limits of Ph. Eur. 3.1.11 and USP ‹661.1›. Sheet preheat is maintained at 142–152 °C; plug-assisted positive forming uses POM-C plug temperatures of 90–110 °C, plug penetration of 70–80% cavity depth, and forming air pressure of 6–8 bar. The formed cavities are sealed against aluminium lidding foil at 150–180 °C, 0.4–0.6 MPa seal pressure, and 0.5–1.5 s dwell. The terminal packaging configuration is a push-through blister pack for tablets or hard capsules with moderate moisture sensitivity; published water vapour transmission rates for 250 µm PVC MONO monolayer are typically 2.5–4.0 g/(m²·d) at 23 °C/85% RH by ASTM F1249. This configuration is not suitable for highly hygroscopic actives unless a barrier coating or cold-form aluminium laminate is selected. Corner thinning below 60 µm is rejected on automated camera inspection after forming because residual wall thickness below this value increases pinhole risk during push-through ejection.
The processing window for deep cavity tablet blisters is constrained at the lower bound by insufficient sheet ductility and at the upper bound by sheet sag and uncontrolled thinning. For a 250 µm PVC MONO sheet with cavity depth-to-thickness ratios above 1.0, the acceptable forming temperature band is 142–152 °C; deviations below 138 °C generate stress whitening at the cavity corners, while deviations above 155 °C produce webbing across land areas and non-uniform flange thickness. Plug-to-cavity clearance is set at 1.8–2.2 mm for 250 µm sheet; smaller clearances produce melt fracture at the plug tip, larger clearances increase sidewall thinning. Forming dwell is limited to 0.3–0.8 s because PVC MONO dehydrochlorination accelerates when residence time at >170 °C exceeds 1.0 s; this kinetic constraint sets the upper forming temperature and the maximum cycle speed of the blister line. Ultrasonic wall-thickness mapping is used in production to verify corner thickness; rejection is triggered when measured corner thickness falls below 60 µm. Film tensile properties are characterised by ASTM D882-18 with tear initiation values below 40 N/mm used to reject off-specification sheet that will split during push-through ejection. The terminal product is a deep-drawn blister for high-diameter tablets where conventional shallow draw ratios are insufficient for tablet clearance.
| Converting step | Material condition | Typical operating range | Equipment or standard reference |
|---|---|---|---|
| Sheet preheat for blister forming | 250 µm non-plasticised PVC MONO | 142–152 °C | Flat-bed blister line with calibrated IR pyrometer |
| PVDC coating weight | Aqueous PVDC dispersion on corona-treated PVC MONO | 40–60 g/m² | Reverse gravure coater, inline corona 38–42 mN/m |
| Flexible PVC film extrusion | Plasticised PVC MONO compound | Melt 170–185 °C, die gap 0.4–0.8 mm | Single-screw extruder, L/D 25:1 |
| IV bag perimeter welding | Plasticised PVC MONO film | Pressure 4–6 bar, dwell 2–4 s | 27.12 MHz RF press with cooled electrodes |
| Injection moulding of port components | Rigid PVC MONO compound | Melt 175–195 °C, injection 70–100 MPa | L/D 20:1, mould 30–50 °C |
| Plastisol gasket gelation | PVC MONO cap liner dispersion | 180–200 °C for 60–120 s | Induction-seal liner coating line |
For single-dose granule trays and bulk granule handling where aluminium foil is excluded to permit post-pack metal detection, 300–500 µm PVC MONO sheet is thermoformed into compartmental trays with peelable lidding. The deeper draw ratio compared with tablet blisters requires a lower plug speed and a higher plug temperature of 100–115 °C; sheet preheat is staged at 145–155 °C to compensate for additional plug contact cooling. Tray cavity depth is commonly 10–20 mm, and the flange width is retained above 6 mm to maintain peelable seal integrity. Sealing against paper/PE or PET/PE lidding is performed at 160–180 °C with 0.3–0.5 MPa pressure and 1.0–1.5 s dwell. The terminal format is a single-dose granule tray for oral reconstitution or a bulk granule storage tray for downstream capsule filling. Because PVC MONO monolayer in this gauge still exhibits measurable moisture ingress, the format is restricted to granulations with low hygroscopicity or short shelf-life assignments; moisture-sensitive formulations require the PVDC-coated variant described in the next section. Dimensional stability is checked after 24 h at 40 °C/75% RH; shrinkage above 0.5% on the cavity length axis is rejected because lidding peel force becomes inconsistent.
Aqueous polyvinylidene chloride dispersions are applied inline to corona-treated PVC MONO sheet at coating weights of 40–60 g/m². The corona pre-treatment is maintained at 38–42 mN/m; below 38 mN/m the dispersion dewets, and above 42 mN/m the PVC surface oxidises sufficiently to reduce heat-seal lacquer anchorage. The coated sheet is dried in staged ovens at 60–90 °C with total residence time of 10–20 s before winding. Moisture barrier improves from a monolayer WVTR of 2.5–4.0 g/(m²·d) to 0.8–1.2 g/(m²·d) at 23 °C/85% RH for 40 g/m² PVDC and below 0.6 g/(m²·d) for 60 g/m² PVDC, as measured by ASTM F1249. Oxygen transmission is correspondingly reduced, which is relevant for oxidation-prone granule actives. The terminal product is a high-barrier blister base used for desiccant-free packaging of hygroscopic granule-filled capsules and unit-dose granules. The process constraint is that PVDC-coated PVC MONO cannot be thermoformed at aggressive deep-draw ratios above 1.2 because the coating cracks at cavity corners; inspection for coating continuity uses dye penetration testing after forming.
Flexible PVC MONO compounds for parenteral fluid contact are formulated with plasticiser loadings of 30–40 phr, using trioctyl trimellitate or di(2-ethylhexyl) terephthalate in non-DEHP configurations, and calcium-zinc stabiliser at 0.5–1.0 phr. The compound is extruded on a single-screw line with L/D 25:1 at melt temperature 170–185 °C; the die gap is 0.4–0.8 mm and blow-up ratio is 2.0–2.5:1 for blown film. The film is cut and perimeter-welded into large-volume parenteral bags by RF welding at 27.12 MHz, with electrode pressure 4–6 bar and dwell 2–4 s. The terminal products are IV solution bags, irrigation containers, and flexible tubing segments. Compliance requires Ph. Eur. 3.1.14, USP ‹661.2›, and ISO 8536-4 for infusion sets; biological evaluation follows ISO 10993-5, ISO 10993-10, and ISO 10993-11. A known operational boundary is the sorption of lipophilic active ingredients into the plasticised PVC matrix; published data for specific API loss rates in long-term infusion configurations is limited, and this format is contraindicated for lipid-based injectable emulsions unless overpouching and short-contact administration are validated.
| Application | Material configuration | Primary compliance framework | Evaluation standard or method |
|---|---|---|---|
| Blister cavities for tablets and hard capsules | Non-plasticised PVC MONO sheet 200–400 µm | Ph. Eur. 3.1.11, USP ‹661.1› | ASTM F1249, ASTM D882-18 |
| PVDC-coated granule blister base | PVC MONO + 40–60 g/m² PVDC | Ph. Eur. 3.1.11, USP ‹661.1› | ASTM F1249, ASTM D3985-17 |
| Large-volume parenteral bags and tubing | Plasticised PVC MONO, TOTM/DEHT 30–40 phr | Ph. Eur. 3.1.14, USP ‹661.2›, ISO 8536-4 | ISO 10993-5, ISO 10993-10, ISO 10993-11 |
| Injection moulded ports and closures | Rigid PVC MONO compound | USP ‹87›, USP ‹88›, ISO 10993-1 | ISO 10993-5, ISO 10993-10 |
| Oral liquid cap liners | PVC MONO plastisol on aluminium foil | FDA 21 CFR 177.1210, USP ‹661.1› | Vacuum decay closure integrity, methylene blue dye ingress |
Rigid PVC MONO compound with K-value 55–60 is injection moulded into luer-compatible ports, break-off closures, and rigid vial adaptors. The injection unit uses a screw with L/D 20:1 and compression ratio 2.0–2.5:1; melt temperature is held at 175–195 °C, mould temperature at 30–50 °C, injection pressure at 70–100 MPa, and back pressure at 0.5–2.0 MPa. Thermal residence time above 190 °C must remain below 3 min to avoid dehydrochlorination; the cylinder is purged with acrylic-based compound before shutdown. The terminal components are sterilised by steam or gamma radiation depending on the assembled device; dimensional stability after steam sterilisation at 121 °C for 15 min is within ±0.3% for port thread diameter when mould temperatures are held at the upper bound. Biological evaluation is performed to ISO 10993-5 and ISO 10993-10, with systemic toxicity per ISO 10993-11 and material characterisation per USP ‹87› and USP ‹88›. Overmoulding of rigid PVC MONO directly onto plasticised PVC tubing is not recommended because the differing heat histories create a weak interface; insert moulding or solvent bonding with cyclohexanone-based adhesive is preferred.
Oral liquid cap liners and induction-seal gaskets are produced from PVC MONO plastisol dispersions. The plastisol is formulated with PVC resin 100 phr, plasticiser 50–80 phr, calcium-zinc stabiliser 1–2 phr, and optional blowing agent 0.5–1.0 phr for expanded liners. The dispersion is deposited onto aluminium foil at coating thickness 0.5–1.0 mm and gelated at 180–200 °C for 60–120 s. The terminal liner is inserted into polypropylene or HDPE closures and induction-sealed to oral liquid bottles. The terminal product is the induction-seal closure liner for syrups, suspensions, and oral solutions. The liner must pass closure integrity testing under vacuum decay and methylene blue dye ingress. Compliance is assessed under FDA 21 CFR 177.1210 for closure gaskets and USP ‹661.1› for plastic material of construction. Torque retention is affected by liner compression set; gasket thickness below 0.4 mm shows elevated channel leak rates in continuous thread closures.
Terminal sterilisation of plasticised PVC MONO injection components by moist heat at 121 °C for 15 min increases the total extractable load compared with non-sterilised components; the concentration increase depends on plasticiser type, film thickness, and aqueous contact medium. Published data for this specific configuration is limited, but the known degradation boundary is that PVC dehydrochlorination accelerates above 140 °C, so dry-heat sterilisation above this temperature is excluded. Extractables are profiled by liquid chromatography with UV detection and headspace gas chromatography-mass spectrometry; elemental impurities are screened under ICH Q3D and USP ‹232› with quantification by USP ‹233›. Plasticiser migration from TOTM-formulated PVC MONO into aqueous parenteral vehicles is lower than that of DEHP-formulated material under identical contact conditions; however, the replacement plasticiser must be qualified for each formulation because pH above 7.5 and solubilising vehicles can increase migration. The terminal component is a terminally sterilised PVC MONO IV bag or port assembly. The operational boundary for high-pH parenterals is pH 6.0–7.5; outside this range, extractable load increases and the container should be evaluated by extraction studies that simulate the maximum clinical contact time and temperature.
Competitive PVC MONO Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
PVC MONO Pharma Grade API is supplied as a monolayer pharmaceutical-grade poly(vinyl chloride) rollstock for immediate packaging of tablet and capsule blister cavities, granule sachets, and selected injectable device components. The designation API in the trade name is a manufacturer’s grade identifier and does not denote an active pharmaceutical ingredient; the material is an inert packaging substrate. Standard rollstock thickness ranges from 150 µm to 400 µm, with width tolerance ± 2 mm and roll length tolerance ± 1%. Residual vinyl chloride monomer is controlled to ≤ 1 ppm when tested according to ISO 6401:2022. Total extractables in water are typically ≤ 10 mg/L under USP <661>, although published data for this specific configuration is limited and end users should verify against the intended dosage form. The film is manufactured without recycled content and without intentional phthalate plasticizers in the low-extractable grade; the standard grade may contain trioctyl trimellitate or other non-DEHP plasticizers. Model designations encountered in trade literature separate the standard thermoforming grade PVC MONO-TF from the low-extractable grade PVC MONO-LE.
For direct application to tablet and capsule blister cavities, the sealing side is corona-treated to a surface energy of 38–42 mN/m, measured by ISO 8296:2019. Inline corona dose is typically 0.3–0.8 kW·min/m²; below 36 mN/m, peel strength to lidding foil becomes variable, while above 46 mN/m, surface crosslinking can contaminate heat-seal jaws. For granule sachets, slit edges are held to ± 0.5 mm and the film is wound on 76 mm cores with web tension 30–60 N to prevent telescoping and creasing. This surface and dimensional control is the main difference from general-purpose PVC sheet used in non-pharmaceutical packaging, where surface energy and edge tolerance are not routinely specified to pharmacopoeial quality levels.
The release specification is divided into chemical, physical, and surface properties. Residual vinyl chloride monomer is determined by headspace gas chromatography after dissolution in dimethylformamide according to ISO 6401:2022; the limit is ≤ 1 ppm. Water vapor transmission rate of a 250 µm film is tested at 38 °C and 90% RH by ISO 15106-3:2023 and falls between 2.0 g/m²·day and 4.5 g/m²·day. Oxygen transmission at 23 °C and 0% RH by ASTM D3985-24 is typically 25–80 cm³/m²·day·bar. The narrow thickness tolerance is critical because deviation alters the thermal mass of the web and therefore the heat input required for stable cavity formation.
| Property | Method | Typical limit or range |
|---|---|---|
| Nominal thickness tolerance | ISO 4593:2018 | ± 5% |
| Residual vinyl chloride monomer | ISO 6401:2022 | ≤ 1 ppm |
| Water vapor transmission rate, 250 µm | ISO 15106-3:2023 | 2.0–4.5 g/m²·day |
| Oxygen transmission rate, 250 µm | ASTM D3985-24 | 25–80 cm³/m²·day·bar |
| Surface energy, sealing side | ISO 8296:2019 | 38–42 mN/m |
| Seal peel strength to lidding foil | ASTM F88/F88M-23 | 4–8 N/15 mm |
| Total extractables in water | USP <661> | ≤ 10 mg/L (published data limited) |
On blister thermoforming lines with plug-assisted contact heating, the material is preheated to 85–110 °C. The forming window is narrow: at plate temperatures below 80 °C, corner thinning and stress whitening occur; above 120 °C, web sagging creates nonuniform cavity depth. A cavity depth of 6–8 mm from a 250 µm sheet is achieved with forming air pressure 4–6 bar and plug speed 50–80 mm/s. Sealing to push-through lidding foil requires jaw temperature 165–185 °C, dwell 0.5–1.5 s, and pressure 3–5 bar; peel strength is then 4–8 N/15 mm when tested according to ASTM F88/F88M-23. Production web thickness is held to ± 5% to prevent punch misalignment and incomplete seal at the cavity perimeter.
In granule sachet sealing, the same corona-treated surface is heat-sealed to a paper or foil laminate at jaw temperature 150–170 °C and dwell 0.3–1.0 s. Seal integrity is verified by vacuum leak testing at −0.25 bar for 30 s; any visible stream of dye indicates pinholing at the seal interface. The film is not suitable for desiccant-free packaging of APIs with high moisture sensitivity because its water vapor transmission rate is moderate. Published data for specific moisture-sensitive formulations is limited; sorption studies under ICH condition II at 40 °C/75% RH should be carried out before commercial use.
The pharma-grade monolayer PVC is distinguished from general-purpose PVC sheet by lower residual vinyl chloride monomer, controlled extractables, absence of recycled content, and tighter thickness and surface energy specifications. Compared with PVDC-coated PVC, the monolayer product has higher moisture and oxygen permeation, but it is less sensitive to preheat in thermoforming and avoids delamination at deep-draw corners. PVDC-coated PVC can reduce WVTR to 0.5–1.5 g/m²·day and oxygen transmission to 1–5 cm³/m²·day·bar for a comparable 250 µm web; however, the PVDC layer may crack or delaminate when cavity depth exceeds 8 mm or when the web is formed below 75 °C. Against PCTFE or COC barrier laminates, PVC MONO has a forming and sealing window closer to conventional tooling, but PCTFE laminates provide WVTR values below 0.05 g/m²·day at 38 °C/90% RH for moisture-sensitive formulations.
| Substrate | Typical WVTR at 250 µm | Typical OTR at 250 µm | Thermoforming window | Main processing limitation |
|---|---|---|---|---|
| PVC MONO monolayer | 2.0–4.5 g/m²·day | 25–80 cm³/m²·day·bar | 85–110 °C | Moderate barrier; not for highly moisture-sensitive APIs |
| PVDC-coated PVC | 0.5–1.5 g/m²·day | 1–5 cm³/m²·day·bar | 75–95 °C | PVDC delamination in deep-draw cavities |
| PCTFE/COC laminate | 0.01–0.05 g/m²·day | 1–10 cm³/m²·day·bar | 90–120 °C depending on tie layer | Higher cost; limited seal-peel consistency on high-speed lines |
For injectable device components, PVC MONO must be evaluated for plasticizer migration into aqueous and lipid-based vehicles. The non-DEHP grade is preferred; standard flexible PVC containing low-molecular-weight plasticizers is not suitable for primary storage of lipid emulsions or high-surface-area aqueous drug solutions because total extractables can exceed USP <661> limits. Components are typically sterilized by ethylene oxide or gamma irradiation at ≤ 25 kGy; dry heat above 121 °C can accelerate dehydrochlorination. Solvent bonding to rigid PVC connectors uses cyclohexanone or tetrahydrofuran, with residual solvent verified by headspace gas chromatography under USP <467>. Published data for the low-extractable PVC MONO-LE configuration in injectable primary containers is limited; qualification testing should include extraction at 40 °C for 14 days using the intended vehicle and analysis by GC-MS or LC-MS.
The selection is process-dependent. Flexible PVC tubing plasticized with DEHP is avoided because of migration and regulatory restrictions in Europe under Regulation (EU) 2017/745 for certain medical devices; PVC MONO-LE is evaluated as an alternative for transfer sets and connector bodies where dimensional stability is required. The material’s rigidity compared with plasticized flexible PVC means that bend radius and fitment design must be adjusted; the tensile modulus of a 250 µm unplasticized PVC film is typically 2.0–2.8 GPa when tested by ASTM D882-18, while flexible PVC may be below 0.2 GPa. In actual production, the higher modulus reduces kinking but increases force to fit over barbed connectors; assembly torque should be controlled to avoid stress cracking, particularly after gamma irradiation.
For oral solid and injectable device component contact, the material is evaluated under separate risk profiles. Oral solid dosage packaging focuses on barrier properties, seal integrity, and absence of extractables that can migrate into dry tablets or capsules. Injectable component contact requires toxicological risk assessment of leachables according to ISO 10993-17:2023, with limits established per ICH Q3C for residual solvents and ICH Q3D for elemental impurities. The product should not be used as a primary container for aqueous injectable drug solutions unless extraction data for the exact formulation are available and reviewed. Conversely, it can be considered for rigid ancillary components where short-term or incidental contact is expected and where dimensional stability after sterilization is required.