| HS Code | 484348 |
| Product Name | PLAJEX™ Ready-to-Fill Polymer Syringe with Tapered Needle Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Brand | PLAJEX™ |
| Product Type | Ready-to-Fill Polymer Syringe |
| Needle Type | Tapered Needle |
| Material | Polymer |
| Grade | Pharma Grade |
| Api Compatibility | Tablet / Capsule / Granule / Injection |
| Administration Route | Oral & Injectable |
| Filling State | Ready-to-Fill |
| Primary Use | API delivery |
| Target Dosage Forms | Tablet, Capsule, Granule, Injection |
| Application Segment | Pharmaceutical |
As an accredited PLAJEX™ Ready-to-Fill Polymer Syringe with Tapered Needle Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaging: 10 ready-to-fill polymer syringes with tapered needles, pharma-grade API, suitable for tablet, capsule, granule, injection, oral and injectable use. |
| Container Loading (20′ FCL) | 20′ FCL loading: palletized PLAJEX™ ready-to-fill polymer syringes with tapered needles, pharma-grade API, secured for tablet, capsule, granule, oral/injectable applications. |
| Shipping | PLAJEX™ is shipped in temperature-controlled, tamper-evident, UN-compliant packaging under GDP/GMP conditions. Gel packs, insulated shippers, or dry ice are used as required. Labels, SDS, and regulatory documentation are included; lot traceability is maintained. Store per label, protecting from light, heat, and moisture. Expedited, monitored delivery is available. |
| Storage | Store PLAJEX™ Ready-to-Fill Polymer Syringes with Tapered Needle in original sealed packaging, upright, in a clean, dry, well-ventilated area at controlled room temperature (15–25°C). Protect from light, moisture, freezing, heat, and incompatible chemicals. Keep away from ignition sources. Do not use if packaging is damaged. Follow manufacturer’s label, SDS, and specification for specific API storage and expiry. |
| Shelf Life | Shelf life depends on storage; refer to PLAJEX™ supplier COA/SDS. Usually 24 months if sealed, dry, cool, protected from light. |
In a nested tub filling environment handling ready-to-fill polymer syringes with a tapered needle, the tub lid is removed under unidirectional airflow certified to ISO 14644-1 Class 5 in the critical zone, while the surrounding area maintains EU GMP Annex 1 Grade B conditions. The barrels are depyrogenated by the supplier and presented in ISO 11607-2 compliant sterile barrier packaging; fill-finish operations therefore do not require a washing step. The polymer barrel is filled through a rotary piston pump or a pre-sterilized rolling diaphragm pump calibrated to deliver 0.25 mL to 1.0 mL with a fill-volume tolerance of ±0.5%, and the headspace bubble is controlled between 2 mm and 4 mm before vacuum stopper insertion. Stopper insertion depth is maintained at 2.5 mm ± 0.3 mm from the barrel flange, consistent with ISO 11040-8:2015 functionality requirements for prefilled syringes. For oxygen-sensitive formulations, nitrogen overlay with residual oxygen below 5% in the headspace is applied before stopper seating. Container closure integrity is verified by deterministic vacuum decay or laser headspace analysis according to USP <1207>, and visible particulate inspection is performed on automated lines with 100% camera coverage following USP <790>. The finished parenteral product is suitable for low-molecular-weight heparin, vaccine, peptide, and oligonucleotide presentations, provided the barrel contact surface meets USP <661.1> and USP <661.2> physicochemical testing and the elastomer stopper complies with USP <381>. A production-scale bottleneck occurs when needle shield placement is not synchronized with stopper seat vacuum; if shield application lag exceeds 0.8 s after stopper seating, tip closure variation can increase the rejection rate due to seal misalignment. The polymer barrel is not intended for terminal steam sterilization at 121°C; terminal sterilization in this system should be limited to validated low-temperature methods or pre-sterilized filling.
High-concentration monoclonal antibody formulations with protein concentrations between 100 mg/mL and 180 mg/mL commonly exhibit dynamic viscosities of 10 mPa·s to 30 mPa·s at 25°C and a shear rate of 1,000 s−1, which is the viscosity window where prefilled polymer syringes with 29G thin-wall tapered needles can still deliver 1 mL doses within 10 s of manual injection. The break-loose force and glide force are measured on a universal testing machine at a crosshead speed of 50 mm/min in accordance with ISO 11040-8:2015, and the acceptance limits are not fixed by the standard but are derived from the formulation viscosity class and intended subcutaneous route. In a polymer barrel without free silicone oil, the break-loose force is governed mainly by stopper elastomer compression set, barrel surface roughness below 0.03 µm Ra, and the coefficient of friction between the halogenated butyl stopper and the barrel. A formulation shift from 10 mPa·s to 20 mPa·s can increase the glide force by 3 N to 5 N on a 29G thin-wall needle, and this must be separated from the needle flow resistance contribution. Needle clogging is not the primary limiting factor at this viscosity; the main process conflict arises during sterile filling because shear-thinning behavior at filling pump speeds of 120–180 cycles/min may produce a measured fill viscosity lower than the resting viscosity that later controls injection force. The following release matrix is applied for high-concentration parenteral configurations:
| Property | Test method | Application-specific release criterion |
|---|---|---|
| Break-loose force | ISO 11040-8:2015 | <15 N for syringe sizes 0.5–1.0 mL at 25°C |
| Gliding force | ISO 11040-8:2015 | <10 N at 50 mm/min test speed |
| Needle penetration force | ISO 11040-8:2015 | Reported by lot with lower and upper internal limits |
| Closure integrity | USP <1207> | No leakage at 50 µm defect sensitivity |
| Subvisible particulates | USP <788> | ≥10 µm ≤6,000 particles per container; ≥25 µm ≤600 particles per container |
| Extractables screening | USP <1663>/<1664> | AET-based reporting under ICH Q3D |
Manufacturing lines running these formulations at 8,000–12,000 syringes/hour observe that stopper insertion force must be profiled against stopper hardness; halogenated butyl stoppers with Shore A hardness 45–55 reduce insertion rebound by 0.3 mm compared with softer 35 Shore A stoppers under vacuum seating. The tapered needle geometry is qualified under ISO 9626:2016 for stainless steel needle tubing, and needle sharpness is released by penetration force on a synthetic substrate at 10 mm/min, not by visual inspection alone.
Lyophilization of the ready-to-fill polymer syringe is performed with the stopper in a vented position, allowing water vapor to escape through the stopper vents while the barrel remains protected by the needle shield. The freeze-drying cycle uses shelf-cooling to -45°C at 0.5°C/min, primary drying at -20°C to -10°C under chamber vacuum between 50 µbar and 200 µbar, and secondary drying ramp to 25°C over 8–12 h. Because polymer barrels have lower thermal conductivity than borosilicate glass, the cake depth is typically limited to ≤10 mm to maintain uniform sublimation across the batch; deeper fills produce a measurable moisture gradient and higher residual moisture at the bottom of the cake. Stopper staking is executed on a multi-head staking station that applies a compressive force of 80–120 N per stopper and confirms final stopper position by laser height measurement. Container closure integrity after staking is retested using USP <1207> vacuum decay because microcracks in the polymer barrel flange can remain invisible to visual inspection. Residual moisture is controlled to ≤3.0% by Karl Fischer titration according to USP <921>, and reconstitution time for a 100 mg/mL lyophilized peptide formulation is measured with 1.0 mL of sterile water for injection at 25°C. The terminal product is a lyophilized injection that is reconstituted immediately before subcutaneous or intramuscular administration. A critical process limitation is that the polymer barrel may not withstand terminal autoclave cycles at 121°C for 15 min; published data for this specific configuration is limited, and any change from lyophilization to terminal steam sterilization must be supported by thermal validation of the barrel resin and needle bonding. Incompatibility with high concentrations of benzyl alcohol or polysorbate above the supplier-qualified limit can increase extractables, so each formulation must undergo USP <1663> extractables screening under accelerated conditions.
For oral unit-dose packaging of pediatric and geriatric suspensions, the needle-bearing syringe is converted to an oral dispenser by removing the needle shield and attaching a Luer-compatible oral tip or an ISO 80369-3 enteral connector before filling. The barrel and plunger system is filled at ambient temperature with a suspension maintained under continuous low-shear agitation, typically a magnetic impeller at 150–250 rpm, to keep the active pharmaceutical ingredient uniformly suspended. Suspension viscosity at 25°C ranges from 50 mPa·s to 250 mPa·s for dose volumes of 0.5 mL to 5.0 mL, and the fill volume tolerance is held at ±2.5% for dose volumes below 2 mL to satisfy USP <905> uniformity of dosage units. For granules intended for reconstitution, the dry powder is filled into the syringe barrel under low-humidity conditions below 30% RH, and the diluent is added at the time of use; this presentation serves patients who cannot swallow tablet or capsule forms and require a measured liquid or reconstituted granule dose. The filling needle or nozzle diameter is selected at 1.2–1.6 mm to prevent clogging by suspended particles, and net-weight checkweighing on high-speed checkweighers operating at 120–200 syringes/min rejects units outside the target mass window. Compliance for the oral presentation relies less on injectable standards and more on USP <661.1> plastic packaging safety, USP <671> container performance for light transmission and moisture barrier, and 21 CFR 211.94 for drug product containers. The finished product is a ready-to-administer unit-dose oral syringe for hospital or community use, with tamper-evident closure indicating first-use integrity. A known failure mode in oral suspension filling is air entrapment in the tip adapter; in-process vacuum deaeration at -0.6 bar for 2–3 s immediately before nozzle shutoff reduces bubble formation by 1.5–2.0 mm in the dose chamber.
Cold chain distribution of polymer prefilled syringes is qualified from 2°C to 8°C for refrigerated biologics and from -20°C to -80°C for frozen formulations, although each temperature range demands separate container closure integrity and plunger movement studies. Polymer barrels exhibit different thermal expansion coefficients than glass, so frozen storage can generate flange stress and microscopic cracking if the barrel is restrained in a rigid nest. Transport qualification uses temperature data loggers with ±0.5°C accuracy placed in worst-case load positions inside insulated shippers, and the shipment is challenged with summer and winter ambient profiles according to ICH Q1A(R2) stability guidance. Before and after freeze-thaw cycling, syringes are tested for break-loose and glide forces under ISO 11040-8:2015 to verify that plunger functionality remains within the original acceptance range. Vacuum decay closure integrity per USP <1207> is executed on 100% of the returned samples in the stability study, because microcracks at the needle hub bond or barrel flange may not be observable by visual inspection. The cold chain terminal product is a ready-to-fill or filled syringe held in a validated passive thermal shipper with phase-change materials configured for 48–96 h transit duration. A practical limit is that frozen storage below -80°C is generally not recommended for polymer-barrel syringes unless the supplier has generated fracture toughness data at that temperature; users should request storage validation data for the specific barrel lot.
Blinded clinical presentations use the identical barrel geometry and tapered needle for active, placebo, and comparator arms to minimize unblinding by visual or tactile differences. The ready-to-fill polymer syringe is filled with either active formulation or matching placebo using the same fill line and the same stopper lot; the only variable is the label text, which is generated under a randomization code compliant with 21 CFR 312 for investigational drug labeling. Clinical trial material packaging is executed under EU GMP Annex 13 and follows the requirements of EU Regulation No 536/2014 for investigational medicinal products. Label copy includes protocol number, randomization number, and storage condition, printed at 200 dpi minimum on tamper-evident vial labels that are verified by automated optical character recognition after application. The dose presentation can be adjusted within the same syringe size by changing fill volume from 0.2 mL to 1.0 mL while maintaining an identical external profile, allowing adaptive dose cohorts without changing secondary packaging. Returned trial stock is reconciled, and unused syringes are destroyed in accordance with Annex 13 and sponsor-specific destruction procedures. Extractable and leachable data from the polymer syringe must be available in the investigator's brochure and the pharmacy manual, because European Medicines Agency guidance expects comparative extractable data when a novel polymer container changes from glass during phase 2 or phase 3 development.
Competitive PLAJEX™ Ready-to-Fill Polymer Syringe with Tapered Needle Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
PLAJEX™ Ready-to-Fill Polymer Syringe with Tapered Needle Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable is supplied as a nested, pre-sterilized primary packaging system for pharmaceutical filling operations. The commercial designation does not identify a separate model code in the public technical bulletin; the configuration is specified by the combination of barrel fill volume, needle gauge, needle length, plunger stopper elastomer, and terminal sterilization method. The system is intended for pharmaceutical-grade active pharmaceutical ingredient fill streams across low-viscosity aqueous injectables, high-viscosity oral suspensions, reconstituted granule slurries, and non-aqueous formulations. In this listing, the phrase “Pharma Grade API” refers to compatibility of the drug-contact surface with pharmaceutical active ingredient processing rather than inclusion of an API in the device.
The primary packaging configuration integrates a polymer barrel, a fixed tapered needle, and an elastomeric plunger stopper into a tub-nested array. Because the assembly arrives pre-sterilized, the filling line does not require barrel washing, siliconization, or depyrogenation tunnels. This removes glass-to-needle insertion operations and their associated particulate generation. The format is evaluated against ISO 11040-6:2019 for plastic barrels and ISO 11040-8 for finished prefilled syringes; the needle cannula is controlled under ISO 9626:2016 and ISO 7864. Compendial suitability is governed by USP <661.1>, USP <661.2>, and Ph. Eur. 3.2.2, while the elastomeric stopper is assessed under USP <381>. The container closure system must satisfy FDA 21 CFR 211.94 for intended use. These methods establish dimensional, functional, and material-safety boundaries before the product enters a filling line.
| Standard or compendial method | Scope | Application to PLAJEX™ ready-to-fill configuration |
|---|---|---|
| ISO 11040-6:2019 | Plastic barrels for injectables and sterilized subassembled syringes ready for filling | Barrel dimensions, closure seating, break-loose and glide force, transparency, water vapor transmission |
| ISO 11040-8 | Finished prefilled syringes | Release testing of filled and closed system, needle sharpness, needle tip defect, leak tightness |
| ISO 9626:2016 | Stainless steel needle tubing for medical devices | Cannula raw material dimensions, tensile properties, surface finish |
| ISO 7864 | Sterile hypodermic needles for single use | Penetration force, drag force, bevel geometry, bond strength |
| USP <661.1> | Plastic materials of construction | Material identity, extractables, physicochemical suitability |
| USP <661.2> | Plastic packaging systems | System-level extractables and leachables risk management |
| Ph. Eur. 3.2.2 | Plastic containers and closures for pharmaceutical use | European pharmacopoeial conformity for polymer contact materials |
| USP <381> | Elastomeric closures for injections | Plunger stopper self-sealing, coring, fragmentation, penetrability |
| FDA 21 CFR 211.94 | Drug product containers and closures | Container closure system suitability, extractables/toxicological assessment, release limits |
Incoming polymer barrels are typically nested in a tub carrier that aligns the flange with the filling-line needle. The fixed tapered needle is visibly different from a separate Luer hub assembly because the cannula is bonded directly to the barrel tip during molding or insert molding. This removes a separable connection and the associated dead volume between the barrel outlet and the needle hub. The exact dead-volume reduction for the PLAJEX™ configuration is not stated in the public technical bulletin, and published data for this specific configuration is limited. Dimensional control of the cannula should follow ISO 9626:2016 for outside diameter, wall thickness, length, and surface finish; needle assembly performance should be verified according to ISO 7864 for penetration force and drag force. The tapered needle geometry may reduce peak insertion force relative to a constant-diameter cannula of equivalent nominal gauge, but the manufacturer’s stated penetration force value is not available in the commercial listing.
For polymer barrel suitability, USP <661.1> tests evaluate identity, extractable metals, UV absorbance, and pH shift. USP <661.2> moves the assessment from material level to the packaging system, requiring extractables and leachables studies under simulated use. Ph. Eur. 3.2.2 applies similar plastic containers and closures requirements in the European context. The elastomeric plunger stopper must pass USP <381> for fragmentation, self-sealing, and coring; closure seating force and break-loose/glide force are measured under ISO 11040-6:2019. The barrel should be inspected for particulate matter against USP <788> for injectable filled units, and for visible particle burden in oral dosage forms.
Ready-to-fill polymer syringes are specified by fill volume, needle gauge, and needle length rather than by a single model code. The public listing for PLAJEX™ does not enumerate the available volume increments, so incoming specifications should be drawn from the manufacturer’s technical datasheet and drug master file. In typical nested ready-to-fill formats, the barrel volume exceeds the label claim by the required headspace for stopper insertion and gas flushing. Fill weight is derived from formulation density at the filling temperature; in-process checkweighing and gravimetric filling are used to control dose accuracy. For high-viscosity oral suspensions, the fill nozzle backpressure and stopper seating speed are adjusted to avoid air entrapment at the barrel shoulder.
| Critical quality attribute | Test method or equipment | Purpose in the fixed-needle format |
|---|---|---|
| Barrel internal diameter and total length | Vision system, calibrated plug gauges per ISO 11040-6:2019 | Ensures plunger travel and dose accuracy |
| Needle gauge, length, and bevel | ISO 9626:2016, ISO 7864 | Controls injection depth and penetration force |
| Break-loose and glide force | Constant-rate force tester, ISO 11040-6:2019 | Confirms acceptable plunger movement without stiction |
| Closure seating force | Force-displacement measurement during stoppering | Prevents tip cap displacement and sterility loss |
| Needle penetration force | ISO 7864 penetration test | Confirms tapered needle sharpness for injection |
| Headspace oxygen | Laser-based headspace analyzer, pharmacopoeial method | Limits oxidative degradation of oxygen-sensitive APIs |
| Silicone lubricant distribution | FTIR or HPLC extractable method, USP <661.2> | Controls gliding behavior and extractable burden |
| Sterility and endotoxin | Sterility test, bacterial endotoxin test | Maintains parenteral safety after terminal sterilization |
On a production-scale ready-to-fill line, the nested tub is de-nested automatically, and the syringe barrel is transported by its flange through filling, stoppering, and tip-cap placement stations. The fixed tapered needle remains exposed, so the line must include needle-shield handling and needle-tip inspection after filling. Filling accuracy is typically controlled by peristaltic or rotary piston pumps; the selection depends on formulation viscosity and shear sensitivity. For aqueous injectable APIs with viscosity below 10 mPa·s, a rotary piston pump with a nominal fill volume of 0.5 mL to 2.25 mL can be validated to achieve in-process relative standard deviations below ±1%, but published data for this specific polymer syringe is limited. For oral suspensions above 100 mPa·s, the fill nozzle diameter and discharge pressure must be characterized to avoid cavitation at the needle inlet. The tapered needle lumen may act as a flow restrictor; therefore, fill speed should be matched to needle gauge and formulation yield stress.
After filling, the plunger stopper is inserted under vacuum or partial vacuum to control headspace oxygen. In fixed-needle configurations, the stopper seating must be deep enough to avoid gas entrapment but shallow enough to maintain plunger rod engagement during later administration. The closure seating force is measured in-line to detect cracked barrels or misaligned stoppers. A barrel made from a polymer can deform at the flange during high-speed stoppering if the nesting plate is not supported; this is a known production failure mode on automatic tub handling systems. Therefore, the line should include flange flatness checks after de-nesting and before filling. The polymer barrel may also generate fewer glass-related particles, but the absence of glass delamination does not remove the need for USP <788> particulate control on finished injectables.
In a conventional glass prefilled syringe, the needle is inserted through the glass tip and secured with an adhesive. This process can introduce tungsten residues, adhesive extractables, and glass tip stress. A polymer fixed-needle format eliminates the glass-to-needle interface and its associated tungsten pin insertion. The comparison is relevant for oxidation-sensitive biologics and high-pH formulations that can accelerate glass delamination. However, published data for this specific configuration is limited, and the manufacturer does not provide a quantitative tungsten residue specification in the public technical bulletin. If tungsten reduction is part of the product quality target, the user should obtain the drug master file extractables profile and compare it with the glass comparator.
Compared with a Luer-lock polymer syringe, the fixed tapered needle removes the Luer connection dead space and the risk of hub-cannula loosening during transport. Luer-lock systems can trap liquid between the barrel tip and the Luer hub, which may be unacceptable for high-potency or high-viscosity formulations where dose recovery is critical. The fixed-needle configuration reduces the number of joint points but also removes the ability to attach a different needle or oral adapter at the point of care. This is an operational boundary: the fixed tapered needle cannot be exchanged for a longer or shorter needle without changing the entire primary container.
The polymer barrel is not universally compatible with all drug formulations. Extractables and leachables must be assessed under USP <661.2> or Ph. Eur. 3.2.2 with the actual drug matrix, pH, and storage temperature. Formulations containing high concentrations of organic cosolvents may affect the polymer surface or plunger stopper. If the product is intended for terminal sterilization by steam, the barrel’s heat deflection temperature and needle adhesive bond must be verified; if ethylene oxide is used, residual gas limits must meet ISO 10993-7. The public technical bulletin does not state the maximum autoclave temperature for the PLAJEX™ system; published data for this specific configuration is limited. Users should not combine the system with amine-based additives or oxidizing agents unless extractables testing demonstrates compatibility. Storage should avoid relative humidity above 60% if the sterile barrier is not protected by a sealed tub and Tyvek lid, because moisture ingress can affect plunger glide force and label adhesion.
For oral use of the same polymer syringe, the needle must be removed or shielded to prevent accidental needle stick. In tablet or capsule applications, the syringe is not a dosage form; it is used to deliver reconstituted suspensions or granule slurries after the solid dosage form has been dispersed. The syringe is not designed for dry powder filling without a liquid carrier, and dry granule loading would require a different closure and barrel geometry.