| HS Code | 985125 |
| Brand | PLAJEX™ |
| Product Name | PLAJEX™ Ready-to-Fill Polymer Syringe with Luer Lock Pharma Grade API |
| Product Type | Ready-to-Fill Polymer Syringe |
| Connection Type | Luer Lock |
| Material | Pharmaceutical-grade polymer |
| Api Grade | Pharma Grade API |
| Intended Dosage Forms | Tablet, Capsule, Granule, Injection |
| Administration Routes | Oral, Injectable |
| Fill Status | Ready-to-Fill |
| Sterility | Sterile |
| Primary Use | Pharmaceutical API handling and delivery |
| Compatibility | Luer Lock connectors |
As an accredited PLAJEX™ Ready-to-Fill Polymer Syringe with Luer Lock Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged as 10 ready-to-fill polymer syringes per carton, with Luer Lock caps, individually sealed in pharma-grade blister packaging. |
| Container Loading (20′ FCL) | 20′ FCL container loading: palletized PLAJEX™ ready-to-fill polymer syringes with Luer Lock, pharma-grade API, packed for oral and injectable use. |
| Shipping | Shipped under GDP-compliant, temperature-controlled conditions in pharma-grade, tamper-evident packaging. Syringes are secured in protective trays with desiccants and shock indicators. Labels and documentation follow applicable regulations. Depending on the API, dangerous-goods classification, approved carriers, and cold-chain logistics may apply. International and domestic shipments require trained handlers and validated thermal packaging. |
| Storage | Store the PLAJEX™ syringe upright in its original, unopened packaging in a clean, dry, well-ventilated area. Protect from direct sunlight, heat, moisture, freezing, and contamination. Maintain controlled room temperature, typically 15–25°C (59–77°F), unless the manufacturer’s label specifies otherwise. Keep away from incompatible substances and follow all GMP and local regulatory storage requirements. Do not use if packaging is damaged. |
| Shelf Life | Shelf life depends on API and packaging; typically 24 months when stored sealed, protected from light, moisture, and heat. |
Cycle development for the PLAJEX™ Ready-to-Fill Polymer Syringe with Luer Lock begins with container closure integrity mapping under ISO 11040-6:2019 for plastic barrels and USP <381> for the elastomeric plunger closure. In a restricted access barrier system operating under EU GMP Annex 1 revision 2022, the syringe is denested from a sealed tub, orientated, and transferred to a rotary filling station. Laminar airflow at Grade A supplies the open barrel between needle shield removal and plunger insertion. Fill weight is controlled gravimetrically. Overfill volume is established from the deliverable volume requirement in USP <1151>, not from nominal fill volume alone. Nitrogen purging of headspace is applied when dissolved oxygen exceeds 2 ppm for oxygen-sensitive injectable drug substances. The plunger is inserted under vacuum after filling to reduce the residual headspace bubble. Closure integrity is verified by dye ingress and vacuum decay as alternatives to microbial immersion. The terminal product is a sterile prefilled Luer lock syringe intended for subcutaneous or intramuscular injection. A terminal sterilization step is not assumed. Where the polymer barrel may not withstand saturated steam at 121 °C without dimensional change, aseptic filling with pre-sterilized components is the controlling process route. Dimensional conformity to ISO 80369-7:2016 is required for the Luer lock taper. The taper must be non-interchangeable with enteral or neuraxial connectors. Extractables profiling under USP <1663> and leachables under USP <1664> is performed with the intended fill solution because the polymer formulation affects the extraction profile. Published data for this specific PLAJEX configuration is limited. Qualification batches must therefore confirm the extractable spectrum before stability protocols are locked. Process limits include a pre-use particulate inspection after washing and before sterilization. Free-floating matter is controlled by USP <790> visible particulate expectations for injectable products. Silicone oil is not a default lubricant in the polymer barrel unless supplied by the manufacturer. If applied, the silicone content is monitored after plunger insertion by atomic absorption and reported in mg per barrel.
The filling line uses servo-driven rotary piston pumps or peristaltic filling heads depending on fill volume. For fill volumes below 0.5 ml, a ceramic piston pump with in-line gravimetric check is preferred because the residual volume in the tubing becomes a larger fraction of the delivered dose. Diving nozzles reduce splashing and foaming. Batch records record fill weights at set intervals. The polymer barrel and Luer lock dimensions are checked against the applicable nominal capacity class under ISO 11040-6:2019. Plunger insertion depth is measured with laser or vision systems. The closure system must withstand a minimum axial pull-off force established during process qualification. No universal force value is assigned because the syringe size and stopper design shift the acceptance envelope.
Field data from automated syringe filling lines indicate that flange distortion is a recurring failure mode when tubs are stored under excessive top load. The flange of a polymer syringe can deform by 0.1 mm to 0.3 mm without detectable visual cracking, which shifts the Luer taper out of coaxial alignment. In subsequent capping, the cap is torqued onto an off-axis taper and may not engage the thread. Automated vision systems using backlit edge detection reject the unit before the fill station. This failure mode is reduced by using tubs with rigid frames and by limiting stacked pallet height. The operational boundary is the inability to assume terminal sterilization. Polymer barrel geometry can distort above the glass transition temperature of the specific polymer grade. Unless the manufacturer provides validated steam sterilization data, aseptic filling remains the only route. Cleaning validation for reusable filling needles must account for API residues below the permitted daily exposure limit. The syringe as supplied is ready-to-fill, so no washing or depyrogenation tunnel is required. That reduces the line footprint compared with bulk glass syringes. The contamination control strategy includes transfer of tubs into the Grade A area by automated portals, glove leak testing, and active air sampling during the fill. Terminal product release testing includes sterility by membrane filtration, bacterial endotoxins per USP <85>, particulate matter per USP <788>, and closure integrity.
| Function | Standard / Clause | Control parameter | Acceptance basis |
|---|---|---|---|
| Plastic barrel dimensions | ISO 11040-6:2019 | Nominal capacity, flange geometry, internal barrel diameter | Conformity to ISO class for the subassembly |
| Luer lock taper | ISO 80369-7:2016 | Dimensional compatibility, leak, pressure resistance | Non-interchangeable with enteral connectors; functional taper fit |
| Plastic packaging safety | USP <661.1>, USP <661.2> | Physicochemical properties, extractable metals | Monograph acceptance limits for plastic packaging |
| Elastomeric plunger | USP <381> | Closure compatibility, turbidity, reducing substances | Elastomeric closure monograph requirements |
| Extractables assessment | USP <1663> | Extraction solvent polarity, temperature, time | Reportable threshold based on AET |
| Biological evaluation | ISO 10993-1:2018 | Cytotoxicity, sensitization, irritation | Acceptance based on contact duration and route |
In hospital and community pharmacy settings, the Luer lock polymer syringe is used to transfer purified water or syrup vehicles into antibiotic dry powders for oral suspension. The compounding process is governed by USP <795> for nonsterile preparations. A common reconstitution ratio is 125 mg/5 ml or 250 mg/5 ml for amoxicillin trihydrate powders, depending on the prescribed strength. The pharmacist draws the vehicle into the PLAJEX syringe through a Luer tip, transfers it into the bulk bottle, and agitates until uniform suspension is achieved. Dose quantity is then verified by displaced volume, not by weight. The syringe used in this transfer step is not the final patient oral dispenser. Direct oral administration through a Luer lock syringe is an operational boundary because ISO 80369-3:2016 requires enteral-specific connectors for feeding and oral administration routes. A Luer tip can accidentally mate with intravenous lines, creating a misconnection hazard. The final patient oral dose is therefore transferred to an ENFit or slip-tip oral syringe after compounding. Beyond-use dates for water-containing oral liquids are assigned according to USP <795>; refrigerated aqueous preparations are typically limited to 14 days unless a longer stability period is chemically justified. The API concentration and viscosity affect the residual volume left in the transfer syringe. Low-volume doses below 1 ml require verification of deliverable volume because the dead space of the Luer hub becomes a larger proportion of the intended dose. A change in hub design from standard Luer to low dead-space Luer reduces residual volume but does not eliminate the need for calibration.
The terminal product is a reconstituted oral suspension labeled with storage conditions and beyond-use date. Visual inspection is performed for color uniformity and absence of particles. The polymer syringe is discarded or reprocessed according to pharmacy waste procedures. It is not supplied as a patient-administered oral device. This segment uses the Luer lock primarily as a closed transfer tool in compounding, not as a finished dosage form container. The compliance focus is different from injectable use: sterility is not required, but accurate liquid transfer and avoidance of connector misconnection are critical.
For batch sizes between 0.5 kg and 25 kg, a Luer lock polymer syringe can meter binder fluid into a high-shear granulator through a side port or a septum-sealed addition port. The terminal product is a granulate for tablet compression or capsule filling. Aqueous binder systems are prepared at 5 % w/w to 10 % w/w polyvinylpyrrolidone K30 in purified water. The addition ratio is set between 5 % w/w and 15 % w/w of the dry powder charge. Lower ratios produce weak granules with high fines; higher ratios extend drying time and can overwet the mass. The syringe is filled from a stainless steel holding vessel and mounted on a syringe driver that delivers fluid at a constant rate over 2 min to 10 min. Manual hand dosing is limited to development batches because the injection rate fluctuates with operator force. For predictable granule growth, the binder is added during the wet massing phase after dry mixing run time reaches 3 min or the pre-set impeller speed is confirmed. Impeller power consumption or torque is used as in-process control. A rise in torque above the dry-mix baseline indicates granule formation. Endpoint is stopped at a target torque value rather than a fixed time. The wet granules are passed through a cone mill with a 1.25 mm to 4.0 mm screen and dried in a fluid bed to a final loss on drying of 1.0 % to 3.0 %. Milled granulate with a D50 of 125 µm to 250 µm is typical for tablet compression. The polymer syringe must be chemically compatible with the binder solvent. Organic solvents can stress-crack the polymer or swell the Luer tip if the polymer grade is not specified for that solvent class. Published data for the specific PLAJEX configuration under acetone or ethanol-water mixtures is limited. Pre-use solvent compatibility testing is required before substituting a glass syringe. Regulatory oversight falls under ICH Q7 for API and intermediate handling and 21 CFR 211.67 for equipment cleaning. The syringe is classified as a product-contact utensil and must be cleaned or disposed of according to the cleaning validation program. Continuous production lines use mass flow controllers or peristaltic pumps, not Luer syringes, because syringe volume per stroke limits throughput. The Luer syringe is appropriate for pilot batches or development scale where total binder volume is under 2 L.
Central intravenous additive service operations use Luer lock syringes for reconstituting freeze-dried injectable products. The syringe draws diluent from a single-dose vial or infusion bag into the barrel through a vented needle or vial access device. It is then attached to the drug vial and diluent is injected against vacuum or with pressure equilibration. The ratio of diluent to dry powder is product-specific. For example, a 500 mg cephalosporin vial may be reconstituted with 10 ml sterile water for injection to give a nominal concentration of 50 mg/ml. The final solution is withdrawn back into the syringe or transferred to an infusion container. Terminal product is a patient-specific sterile injectable solution. The process is performed inside an ISO 5 laminar airflow workbench within an ISO 7 buffer area per USP <797>. The beyond-use date is assigned according to the USP <797> risk-level category. For low-risk compounded sterile preparations made from sterile ingredients in a controlled environment, the maximum storage period is limited by chemical stability and container closure. Hazardous drug reconstitution follows USP <800> and requires closed-system transfer devices if the drug is on the NIOSH hazardous drug list. The Luer lock interface must meet ISO 80369-7:2016 to ensure secure needle attachment. However, the Luer connection is a known point of accidental disconnection if not fully threaded. Use of a Luer-activated valve or closed-system transfer device reduces exposure risk. The polymer syringe in this workflow is not stored beyond the immediate use period unless the compatibility data supports extended filling. Residual diluent volume in the syringe dead space is a dose accuracy variable. Low-dead-space Luer hubs reduce carryover but must be validated for each diluent viscosity.
Clinical trial material filling lines operating with fewer than 500 units per batch present a different set of control requirements. The PLAJEX RTF polymer syringe is placed into a small-scale aseptic isolator where glass prefilled syringe supply chain is not economically justified. Filling is performed with a semiautomatic syringe filler or manual repeating pipette under Grade A conditions. The fill volume range extends from 0.2 ml to 2.25 ml, depending on the investigational drug product. Each lot is inspected for visible particles per USP <790> and for container closure integrity before release. Labeling follows EU GMP Annex 13 for investigational medicinal products and 21 CFR 312.60 for investigational drug accountability. The terminal product is an investigational sterile injectable in a Luer lock prefilled syringe. Release testing includes sterility, endotoxin, and extractables where the formulation is novel. The extractables assessment under USP <1663> is compressed into the clinical trial timeline. If published data for the specific PLAJEX configuration is limited, the sponsor generates bracketing data using worst-case solvents and extraction conditions. The polymer syringe must be compatible with the clinical formulation; pH extremes below 3 or above 9 may change the extracted profile. A pH screen is therefore performed before the first human dose. The polymer barrel also must withstand storage at −20 °C if the formulation is frozen prior to use. Low-temperature brittleness is not assumed and must be demonstrated by drop testing of filled syringes at the intended storage temperature.
Steam sterilization at 121 °C cannot be assumed for a ready-to-fill polymer syringe unless the barrel grade is explicitly validated for autoclave cycles. Many polymer syringes are intended for aseptic filling after gamma or ethylene oxide sterilization, not for in situ terminal sterilization of the filled product. In veterinary multi-dose injectable formulations, the use of a Luer lock polymer syringe as a filling transfer line component is more common than as a final container. The syringe transfers sterile-filtered veterinary drug solution from a collection vessel into sterile vials or multi-dose bottles. Terminal product is a multi-dose veterinary injectable containing a preservative. Benzyl alcohol at 1.0 % v/v to 2.0 % v/v is used in many veterinary parenterals to maintain antimicrobial effectiveness. The preservative concentration is confirmed by high-performance liquid chromatography after filling. The polymer syringe must be chemically resistant to the preservative system and any glycol or benzyl alcohol co-solvents. Prolonged contact can extract leachables into the drug solution. The filling process is conducted in a cleanroom under VICH GL1 validation principles and 21 CFR 211.113 microbial control requirements. The batch size is typically 20 L to 200 L. The Luer lock connection in transfer lines must be secure because pressure from a peristaltic pump or nitrogen pressurization can reach 0.5 bar to 1.0 bar. A non-Luer high-pressure fitting is used if the line pressure exceeds the Luer lock rated pressure. The polymer syringe is discarded after the batch. It is not reused across product contact cycles. The operational limitation is the absence of validated terminal sterilization for the filled polymer syringe unless the manufacturer supplies autoclave cycle data. Therefore terminal product sterility is achieved by membrane filtration and aseptic filling, not by post-fill autoclaving. The polymer barrel’s dimensional stability at elevated temperature must be verified by measuring flange flatness and Luer taper after a simulated autoclave cycle. Distortion of the Luer taper beyond the dimensional limits of ISO 80369-7:2016 rejects the component.
Competitive PLAJEX™ Ready-to-Fill Polymer Syringe with Luer Lock Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
PLAJEX™ Ready-to-Fill Polymer Syringe with Luer Lock Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable is supplied as a washed, lubricated, and terminally sterilized primary packaging component intended for fill-finish operations across oral and injectable dosage forms. The barrel is fabricated from pharmaceutical-grade cyclic olefin polymer or cyclic olefin copolymer resin conforming to USP <661.1> and Ph. Eur. 3.1.3 after extraction testing. The closure system comprises a bromobutyl plunger stopper laminated with a fluoropolymer barrier film on the product-contact surface, and a tamper-evident tip cap. The Luer lock adapter is integrally molded rather than adhesively bonded or ultrasonically welded. Conformity testing is performed to ISO 11040-6 for plastic barrels and ISO 11040-8 for finished prefilled syringes. The system is intended for manual dosing only; it is not qualified as a power-injector syringe. Sterile configurations are validated to a sterility assurance level of 10⁻⁶ in accordance with ISO 17665-1:2006 using a 121 °C saturated steam cycle for 15 min. For heat-sensitive fill lines, ethylene oxide sterilization is available with residual ethylene oxide controlled to ISO 10993-7:2008. The ready-to-fill configuration includes pre-applied silicone oil at a release window of 0.25–0.75 mg per 1.0 mL barrel when silicone oil is specified. A silicone-free barrel configuration is available for protein formulations sensitive to interfacial silicone, but break-loose and glide forces increase by approximately 20–40% depending on fill volume and formulation viscosity.
The product line is supplied in four standard volumes with configurable closure formats. The following table lists standard dimensions after molding and terminal sterilization. Length tolerance under the Luer collar is ±0.5 mm; barrel inner diameter tolerance is ±0.05 mm. Wall thickness variation across the barrel is maintained below 0.05 mm by cavity pressure monitoring on multi-cavity hot-runner injection molding tools. The Luer tip orifice is 2.3 mm in diameter for all standard configurations, which is the critical flow restriction for reconstituted suspensions and high-viscosity oral liquids.
| Model code | Nominal fill volume | Barrel inner diameter | Length under Luer collar | Terminal sterilization |
|---|---|---|---|---|
| PLAJEX-RTF-LL-01 | 1.0 mL | 6.4 mm | 54.0 mm | Steam 121 °C/15 min or ETO |
| PLAJEX-RTF-LL-02 | 2.25 mL | 8.6 mm | 62.0 mm | Steam 121 °C/15 min or ETO |
| PLAJEX-RTF-LL-05 | 5.0 mL | 12.2 mm | 75.0 mm | Steam 121 °C/15 min or ETO |
| PLAJEX-RTF-LL-10 | 10.0 mL | 15.8 mm | 90.0 mm | Steam 121 °C/15 min or ETO |
Custom fill volumes within 0.5–20.0 mL are available on order, but dimensional qualification data for non-standard volumes should be generated on the intended fill-finish line because published data for this specific configuration under high-viscosity reconstituted granule suspensions is limited. Barrel transparency is specified as transmittance ≥90% at 550 nm through the sidewall, measured by a validated spectrophotometer, to allow visual inspection for particulate contamination after filling. Printed graduations are pad-printed with a pharma-grade ink cured at 120–130 °C; adhesion is tested by tape peel and solvent rub according to ISO 2409.
Because the Luer lock collar is injection molded as part of the barrel, no metallic insert or adhesive interface exists at the critical load-bearing thread. Thread form, taper, and lock torque are verified against ISO 80369-7:2021. The taper is the standard 6% Luer taper, with thread engagement of ≥1.5 turns achieved with compatible mating hubs. Torsional resistance after locking is specified as ≥0.2 N·m and ≤1.0 N·m for hand removal. Because the syringe is supplied without a needle, safety needle systems must be validated separately. The product is not an enteral connector; ENFit connectors conforming to ISO 80369-3 are incompatible with the Luer lock, and an adapter validated for Luer-to-enteral conversion is required if the same device is used for enteral administration of reconstituted tablet, capsule, or granule preparations.
The ready-to-fill configuration is delivered double-bagged and may be introduced into a Grade A / ISO 5 filling zone after outer bag removal. Terminal steam sterilization uses a gravity displacement or air-overpressure cycle at 121 °C for 15 min with a validated kill rate sufficient to achieve 10⁻⁶ SAL. Ethylene oxide processing for temperature-sensitive barrel components is conducted at 55 °C and 60% RH with ethylene oxide concentration of 600 mg/L, followed by aeration to residual limits specified in ISO 10993-7:2008. The syringe barrel is not autoclavable above 130 °C; repeated autoclaving cycles should be avoided because thermal exposure above the glass transition of cyclic olefin polymer can produce dimensional drift. For oxygen-sensitive injectable formulations, stoppering under nitrogen overlay with residual headspace oxygen below 2.0% is required because cyclic olefin polymer has higher gas permeability than borosilicate glass. Closure integrity is verified by vacuum decay using a pressure differential of 50 kPa or by dye ingress per USP <1207>. The syringe is not intended for high-pressure infusion or power injection; sustained internal pressure should not exceed 3.0 bar during manual administration because Luer lock engagement is designed for hand torque rather than mechanical pump forces.
Compatibility with tablet, capsule, and granule reconstitution is limited to oral or enteral workflows where the Luer tip is not directly connected to intravenous lines. For granules, the syringe is used to meter purified water into a unit-dose container; after reconstitution, the suspension is withdrawn through the Luer lock and administered via a validated oral adapter. Plunger force acceptance for water for injection is ≤15 N to initiate movement and ≤20 N to sustain glide at 1.0 mL/s using a universal testing machine. For suspensions with median particle size above 150 µm or solids content above 10% w/w, tip occlusion is a documented risk at the 2.3 mm Luer orifice, and a larger-bore model or filtered enteral adapter should be selected. The Luer lock syringe is not a passive safety device and does not include a needle shield, sharps injury protection, or an anti-needlestick mechanism.
Compared with borosilicate glass prefilled syringes, the polymer system reduces mass by approximately 35–50% in the 1.0 mL format. It eliminates glass lamellae formation at alkaline pH and tungsten oxide residue associated with staked-needle glass syringes. The chemical compatibility boundary is aqueous solution contact within pH 2–12; below pH 2, acid-catalyzed surface degradation of cyclic olefin polymer can generate oligomeric extractables above the USP <661.1> collection threshold. The product should not be filled with ketones, aromatic hydrocarbons, chlorinated solvents, or strong oxidizing acids because these agents can stress-crack the barrel or swell the tip cap. For oxygen-sensitive active pharmaceutical ingredients, a secondary aluminum foil overwrap or nitrogen flush is necessary; published oxygen transmission data for this exact resin in ready-to-fill geometry is limited and should be obtained from the resin supplier for the selected wall thickness and storage temperature.
Compared with a two-piece polymer syringe with an inserted metal Luer insert, the integral molded collar removes one metal extractable source and one assembly torque failure point. The fluoropolymer-laminated plunger reduces exposed rubber contact area but does not eliminate silicone oil entirely when a siliconized barrel is specified. For proteins that aggregate at silicone interfaces, the silicone-free barrel configuration is recommended; however, the higher break-loose force must be accommodated in the final device design because hand injection force can exceed 30 N at low barrel temperatures.
| Requirement | Standard / method | Release criterion |
|---|---|---|
| Luer taper and lock | ISO 80369-7:2021 | Conforms; engagement ≥1.5 turns |
| Plastic barrel | ISO 11040-6 | Dimensional conformance and closure fit |
| Finished prefilled syringe | ISO 11040-8 | Piston glide, closure integrity, break-loose force |
| Subvisible particulate matter | USP <788> | ≤6,000 particles ≥10 µm and ≤600 particles ≥25 µm per container |
| Visible particulate matter | USP <790> | Practically free from visible particles |
| Elastomeric plunger stopper | USP <381> | Functional and extractables profile |
| Biological evaluation | ISO 10993-1:2018 | Cytotoxicity, sensitization, irritation, and systemic toxicity |
| Residual ethylene oxide | ISO 10993-7:2008 | Below limit for transient patient contact |
The product is not intended for dry powder storage as a primary container for long-term stability because the barrel is not equipped with a robust moisture barrier equivalent to glass. For lyophilized injectable presentations, the single-chamber configuration can be used with a vial adapter after reconstitution, but the manufacturer must requalify closure integrity for the freeze-drying cycle. Published data for this specific configuration under freeze-drying chamber pressures below 0.1 mbar is limited. The syringe should not be combined with amine-based additives that can react with residual silicone or fluoropolymer surfaces, and it is not compatible with water-miscible organic co-solvents above 10% v/v unless specific extraction studies are completed. Terminal sterilization after filling with volatile active pharmaceutical ingredients is not recommended; residual moisture and headspace condensation may affect the Luer lock thread and printed graduation adhesion.