| HS Code | 696398 |
| Product Name | NEST Cartridge Assembly for Pen-injectors Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Brand | NEST |
| Product Category | Pharmaceutical Packaging and Drug Delivery Component |
| Product Type | Cartridge Assembly for Pen-injectors |
| Grade | Pharma Grade |
| Api Grade | Pharma Grade API |
| Dosage Form Compatibility | Tablet, Capsule, Granule, Injection |
| Route Of Administration | Oral, Injectable |
| Intended Use | Pen-injector drug delivery and API handling |
| Compatibility | Pen-injectors |
| Manufacturer | NEST |
As an accredited NEST Cartridge Assembly for Pen-injectors Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Each carton contains 100 pharma-grade NEST cartridge assemblies for pen-injectors, suitable for oral tablets, capsules, granules, and injectable formulations. |
| Container Loading (20′ FCL) | 20′ FCL container loading: NEST Cartridge Assembly for Pen-injectors, Pharma Grade API, suitable for tablet, capsule, granule, oral and injectable. |
| Shipping | Shipped in sterile, tamper-evident, temperature-controlled packaging compliant with GMP/GDP and IATA regulations. Cartridges are protected from light, moisture, shock, and contamination. Use validated cold-chain or ambient conditions as specified, with monitored data loggers. Labeling includes batch, expiry, handling, and safety information. Secure, traceable delivery to qualified pharmaceutical facilities only. |
| Storage | Store NEST Cartridge Assembly for Pen-injectors Pharma Grade API in its original, unopened packaging in a clean, dry, well-ventilated area at controlled room temperature (15–25°C). Protect from moisture, light, dust, and temperature extremes. Keep away from incompatible chemicals and contamination sources. For injectable/oral use, maintain sterility and follow the manufacturer’s CoA/SDS storage instructions. Handle aseptically where required. |
| Shelf Life | NEST cartridge assemblies typically have a 2–5 year shelf life when unopened, stored dry, protected from light, and kept per manufacturer conditions. |
A NEST cartridge assembly specified for reusable pen-injector platforms is evaluated as a metering subassembly rather than as passive packaging. The glass cylinder is Type I borosilicate conforming to USP <660> and dimensional requirements aligned with ISO 11040-4, with a fluorine-treated or silicone-coated interior surface whose coefficient of friction must remain stable after filling, terminal sterilization when the formulation allows, and extended shelf-life simulation. Elastomer closures are tested under USP <381> for extractables, penetrability, and reseal characteristics after multiple needle insertions. In use, the rotary dose selector of the pen device advances a threaded piston rod against the elastomeric plunger; dose accuracy therefore depends on both thread pitch of the device mechanism and the plunger break-loose and gliding force measured through the filled cartridge. Fill volume is commonly 1.5 mL or 3.0 mL for insulin analogues administered in 0.5 IU or 1 IU increments, though pen platform-specific dimensions must match cartridge neck, flange geometry, and shoulder under ISO 11608-1:2022. On production lines, batch-to-batch variability in siliconization is a recurring failure mode: excessive silicone oil can migrate into the drug product and form visible protein-silicone aggregates, while insufficient silicone coating raises break-loose force above the device motor or patient hand force limit after 4–6 weeks of storage at 2–8°C. Filling operations for cartridge-based injectables typically occur in Grade A isolator or restricted access barrier systems under ISO 14644-1:2015 Class 5, with 21 CFR 210 and 21 CFR 211 governing aseptic assembly. The closure seating station must control crimp height and perpendicularity because a tilted plunger or misaligned cap produces non-linear gliding force and can cause leakage during pen actuation. Automated checkweighing and vacuum decay testing are inserted after final assembly to reject units with poor container closure integrity.
Neutral-pH soluble insulin formulations can contain phenol and m-cresol as preservatives, zinc ions as stabilizers, and phosphate or citrate buffers that complex with extractable sodium and borate species from Type I borosilicate glass. When the cartridge interior is exposed to these buffers over 18–24 months at 5°C, the hydrated glass network can release aluminum, boron, and silicon into solution; subsequent pH shifts or drying at the fill line can detach silica-rich flakes that are detected as visible particulates under USP <790>. The failure mode is not generic glass attack but a formulation-dependent ion exchange amplified when cartridges have been over-washed or subjected to ammonium sulfate treatment under suboptimal conditions. The relevant test guidance is USP <1660>, which distinguishes lamellae, flakes, and pitting. Process control includes acid/ammonium sulfate treatment, high-temperature forming profiles, and limited exposure to alkaline wash solutions. On filling lines, cartridges are depyrogenated in a tunnel with a target endotoxin reduction of 3 log and then cooled prior to aseptic filling. Glass delamination may not be visible immediately after fill; it can develop after variable lag periods of 3–12 months, making real-time release insufficient. A stability-indicating accelerated extraction study is therefore required according to ICH Q1A(R2), with periodic visual inspection under light obscuration and membrane microscopy. Published data on specific NEST cartridge interior durability under individual insulin formulations may be limited, so the extraction profile must be verified on the actual commercial fill line.
| Application-specific requirement | Standard or test method |
|---|---|
| Cartridge glass chemical durability | ISO 11040-4, USP <660>, USP <1660> |
| Elastomeric closure penetration and reseal | USP <381> |
| Pen-injector dose accuracy | ISO 11608-1:2022 |
| Visible and subvisible particulate matter | USP <790>, USP <787> |
| Cleanroom classification for aseptic fill | ISO 14644-1:2015 |
| Aseptic processing compliance | 21 CFR 210, 21 CFR 211, ISO 13485:2016 |
| Oral dosage uniformity and dissolution | USP <905>, USP <711> |
| Elemental impurities | ICH Q3D |
In single-dose autoinjector platforms, a compressed spring drives the stopper through the glass cartridge to deliver a fixed dose of 0.5 mL or 1.0 mL within a predetermined injection time. The cartridge assembly used in this format is not accessed by the patient for replacement; it is integrated into a preassembled subassembly or final device. The mechanical stress profile differs from a reusable pen because the spring force, commonly designed to overcome 20–30 N of stopper force at peak as measured on a universal testing machine at 100 mm/min crosshead speed, is transmitted through the cartridge finger flange or neck shoulder. A Type I glass cartridge with ISO 11040-4 dimensional tolerances must resist biaxial stress during activation, particularly when the device uses a needle shield or auto-insertion mechanism. Production-scale verification includes dose accuracy testing under ISO 11608-1:2022 with a calibrated test rig that records delivered volume at minimum, medium, and maximum fill conditions. Injection time is constrained by the rheology of the formulation; high-viscosity monoclonal antibody solutions in the range of 20–35 cP require larger spring force, which in turn increases risk of cartridge shoulder breakage if the glass wall thickness distribution is not controlled. Needle insertion friction and rubber stopper extrusion force are measured after device activation, and any glass particles generated during spring release must be below the visible particulate limits of USP <790>. The process boundary is that not all cartridge assemblies qualified for low-viscosity aqueous solutions are automatically suitable for viscous antibody or depot formulations.
A direct-compression formulation for a low-dose oral tablet requires API particle size distribution, bulk density, and flow properties to be measured before blending with microcrystalline cellulose, lactose monohydrate, croscarmellose sodium, and magnesium stearate. If the API has a d90 below 150 µm and a Hausner ratio above 1.35, the powder blend may segregate in the hopper and produce tablet content uniformity outside USP <905> acceptance criteria. On a high-speed rotary tablet press running at 80–120 rpm with a 10 mm round flat-faced bevel-edge tool, die fill consistency is controlled by granule or powder flow; compression force is typically maintained between 8 kN and 14 kN for a 200 mg target fill weight, with precompression at 2–4 kN. Dissolution testing under USP <711> in 900 mL of medium at 37°C and paddle speed 50 rpm confirms that magnesium stearate at 0.5–1.0 wt% does not confer excessive hydrophobicity. The manufacturing process is governed by 21 CFR 211, and elemental impurities are controlled according to ICH Q3D. On production lines, over-lubrication in a V-blender beyond 5 minutes can reduce tablet tensile strength and slow dissolution, while under-lubrication can cause picking and sticking on punch faces.
Dry granulation is selected for moisture-sensitive oral APIs that cannot tolerate wet granulation. The API is blended with intragranular binder, often microcrystalline cellulose and crospovidone, then fed into a roller compactor with side seals and a feed screw. Ribbon density is a primary control variable, typically maintained between 0.9 g/cm³ and 1.2 g/cm³ depending on formulation; a ribbon density below 0.8 g/cm³ generates excessive fines, while above 1.3 g/cm³ produces hard granules that resist compaction and yield tablets with low tensile strength. Milling through a screen aperture of 0.8 mm to 1.25 mm produces granules with a bimodal size distribution that must be controlled to prevent content uniformity drift. Tablet compression then proceeds at 10–16 kN on a rotary press, with acceptable tablet hardness in the range 60–120 N for round convex tablets. Process analytical technology including near-infrared spectroscopy is integrated to monitor granule moisture at below 3.0% loss on drying. The entire operation is governed by 21 CFR 211 and ICH Q3D; if the API is a critical-dose compound, occupational exposure limits are controlled through contained roller compaction. In commercial scale-up, ribbon porosity variations across the roll width can shift granule density by 0.1–0.3 g/cm³ if the roll surface is not cooled uniformly.
Capsule finishing for oral APIs produced by fluid-bed granulation is constrained by the interaction of granule cohesivity, electrostatic charge, and gelatin or HPMC capsule shell moisture. Top-spray fluid-bed granulation with binder solution at 2–5% solids and inlet air temperature between 60°C and 75°C produces granules with bulk density 0.45–0.65 g/cm³ and Hausner ratio 1.15–1.35. After drying, granules are milled through a 0.6–1.0 mm conical mill screen and lubricated with sodium stearyl fumarate to reduce punch sticking. During capsule filling on a dosator or tamping pin machine, powders with high triboelectric charging attach to capsule shells and cause fill weight variability exceeding 4.0% RSD. Moisture is adjusted to 1.5–3.0% loss on drying because too-dry granules increase electrostatic adhesion, while wetter granules may cause plug formation. Dissolution testing under USP <711> with 900 mL medium at 37°C and paddle speed 50 rpm is used to confirm that capsule lubrication did not inhibit release. The capsule shell itself is tested for moisture content by Karl Fischer titration, usually 13–16% for gelatin; HPMC capsules are used when the API is hygroscopic or requires low aldehyde content. Process robustness is established through six-batch scale-up, and any change in granule particle size distribution must trigger re-verification of capsule fill weight under USP <905>.
Lyophilized injectable APIs are not compatible with standard cartridge assemblies in most commercial configurations because a cartridge stopper must maintain gliding movement along a narrow barrel, whereas lyophilization requires a partially seated stopper with a venting gap for sublimation. The filling line for a lyophilized product operates with a vial geometry that permits handshake stopper insertion and later full closure after chamber stoppering; this process is different from cartridge filling, where the plunger is inserted to a defined depth under vacuum or with a fill ring. Residual moisture after lyophilization is controlled by Karl Fischer titration according to USP <922>, with typical targets below 1.0% for small-molecule drugs and below 3.0% for some protein formulations. Reconstitution time and cake integrity are observed visually and by light obscuration under USP <790> after shaking. The operational boundary is that an API specified for injection can be formulated as a ready-to-use solution in a cartridge, as a lyophilized powder in a vial, or as an oil-suspension in a prefilled syringe, but the cartridge assembly does not substitute for a vial in the lyophilization unit operation. Published data on lyophilized NEST cartridge-compatible formats is limited; therefore process qualification must confirm that the glass barrel, elastomer formulation, and fill depth can withstand freezing, primary drying, and secondary drying without losing dimensional tolerance.
Competitive NEST Cartridge Assembly for Pen-injectors Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-petrochem.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@ascent-petrochem.com
Flexible payment, competitive price, premium service - Inquire now!
The NEST cartridge assembly for pen-injectors is configured as a ready-to-fill primary container closure system for sterile liquid formulations containing pharmaceutical grade APIs intended for subcutaneous, intramuscular, or intradermal delivery. The line includes 1.5 mL and 3.0 mL nominal fill configurations assembled from a cyclic olefin polymer barrel, a chlorobutyl plunger with an ethylene tetrafluoroethylene fluid-contact laminate, and an aluminum crimp cap with an elastomer septum. Break-loose force is specified at 12 N to 20 N and sustaining glide force at 6 N to 12 N when tested with a 23G needle at 100 mm/min. The assembly is intended for aseptic filling of aqueous solutions, suspensions, and low-viscosity depot formulations; it does not accept dry-powder, tablet, capsule, or granule APIs. Dimensional compatibility follows ISO 11608-3:2022 for pen-injector finished containers, and manufacturing is managed under ISO 15378:2017 primary packaging GMP. Published data for specific NEST-CA batch drawings is limited to supplier-controlled engineering documentation.
Model selection for the NEST pen-injector cartridge is based on nominal fill volume and closure format. The NEST-CA-1.5-LC and NEST-CA-3.0-LC configurations use a laminated chlorobutyl plunger and a cyclic olefin polymer barrel. Critical dimensions for the 3.0 mL model include a body outer diameter of 11.6 mm, a total length of 61.5 mm, and a neck bore of 5.6 mm, with tolerances of ±0.1 mm, ±0.3 mm, and ±0.05 mm respectively. Dimensional conformance is checked by laser micrometrology at 240 units/min after injection molding. The cartridge interior is treated with a polydimethylsiloxane silicone oil application of 0.4 mg to 0.8 mg per barrel after final washing to reduce plunger friction; barrel surface roughness is controlled below 0.8 µm Ra on the fluid-contact surface. The laminated plunger closure is coated with ethylene tetrafluoroethylene film 0.10 mm to 0.15 mm thick to limit rubber extractables. The aluminum crimp cap uses Al 3003-H14 alloy and is epoxy lacquered; crimp retention force is specified above 60 N.
Processing of the polymer barrel occurs on all-electric injection molding machines with clamp force between 800 kN and 1,200 kN. Hot-runner valve gating is applied at the neck to reduce gate vestige and maintain concentricity within 0.05 mm total indicator runout. In-process annealing at 110 °C for 2 h is used to stabilize molded-in stress before washing and siliconization. Elastomer stoppers are compression molded, washed with USP purified water, and depyrogenated to an extractable endotoxin level below 0.25 EU/mL. After assembly, online vision systems measure cap crimp height, barrel length, and septum presence at rates up to 240 units/min. Packaging for the cartridge includes a polycarbonate tub and breathable polyester lid; validated shipping configuration follows ASTM D4169-22 distribution cycle assurance level II, with cold-chain compatibility down to -20 °C for filled aqueous formulations. Shipping of dry cartridges at 60 °C for 72 h has not shown dimensional drift beyond 0.1% of total length.
Terminal steam sterilization is validated at 121 °C for 15 min with overpressure ramp not exceeding 2.5 bar/min. Cyclic olefin polymer retains a glass transition temperature of 136 °C to 140 °C by differential scanning calorimetry, allowing this cycle without barrel collapse. Sterilization above 125 °C is not recommended because total length shrinkage can exceed 0.3 mm and compromise pen-injector dose setting. For cold-chain formulations stored at -20 °C or -40 °C, the polymer barrel exhibits lower elongation at break of 8% to 12% compared with 30% to 40% at room temperature; thawing should be controlled at ≤ 0.5 °C/min to avoid neck stress cracking. Plunger glide force can increase 6% to 12% after one freeze-thaw cycle due to elastomer compression set. Formulations with high ice-crystal volume expansion should be evaluated for performance using 50 mL pilot cartridges before production scale-up. The laminated plunger maintains contact with the barrel after low-temperature storage, but subvisible particle formation should be checked per USP <787> and USP <788>.
Extractable and leachable assessment is based on USP <1663> and USP <1664>. Extraction solvents include 0.9% sodium chloride, 10% ethanol/water, and pH 3.0 citrate buffer. Total organic carbon after 14 days at 70 °C is below 0.5 mg/L from the polymer barrel. Headspace gas chromatography-mass spectrometry screening detects no benzene, toluene, ethylbenzene, or xylene above 0.1 µg/L. Elemental impurity control follows ICH Q3D for parenteral dosage forms, with particular attention to aluminum, chromium, and copper in elastomer and cap components. Because the fluid path is glass-free, the assembly avoids pH shift associated with Type I borosilicate glass delamination in high-alkaline formulations above pH 8.0. However, silicone oil migration in high-pH protein formulations can contribute to subvisible particles above 10 µm; particle burden should be measured using light obscuration and flow imaging after agitation.
Break-loose force for the NEST-CA-3.0-LC after 14 days at 40 °C and 75% RH is 12 N to 20 N. Sustaining force at 100 mm/min is 6 N to 12 N. These values are measured with a constant-speed tensile tester equipped with a 1 kN load cell and a 23G pen needle. Septum needle penetration force is specified below 10 N for a 29G needle and below 12 N for a 27G needle. The septum withstands 4 repeated punctures with a 29G needle without visible fragmentation and retains microbial barrier properties after 7 days immersion in Staphylococcus aureus at 108 CFU/mL. Container closure integrity is confirmed by vacuum decay at -400 mbar with a detection limit equivalent to 0.05 µm hole size, and dye ingress using 1% methylene blue at 650 mbar vacuum for 30 min. Dose accuracy in pen-injector platforms depends on the interface between cartridge shoulder and pen drive; axial runout across the shoulder is limited to 0.05 mm to prevent ratchet misalignment.
Fill-finish operations are compatible with rotary piston pumps and plunger insertion stations. Fill weight for a 3.0 mL aqueous formulation is maintained within ±2% by 100% checkweighing. Headspace residual oxygen is reduced to below 3% for oxidation-sensitive APIs by nitrogen flushing before plunger insertion. Aluminum cap crimping torque is controlled between 0.8 N·m and 1.2 N·m. The cartridge is not suitable for use as a high-pressure syringe pump reservoir because sustained plunger forces above 40 N can induce localized deformation at the neck shoulder and alter dose accuracy. Elastomer closure insertion depth is controlled to 2.0 mm to 2.8 mm below the barrel flange to maintain headspace and avoid plunger contact with the cap septum during storage or transport.
Compared with Type I borosilicate glass cartridges of equivalent 3.0 mL fill volume, the NEST polymer cartridge eliminates glass delamination and reduces breakage risk in portable pen-injector applications. Glass cartridges typically exhibit higher dimensional rigidity at autoclave temperatures, but their extractable profile can include silicon, boron, and aluminum under aggressive buffer conditions. The polymer barrel has lower mass: approximately 1.8 g for the 3.0 mL body compared with 4.0 g to 5.0 g for a glass cartridge of the same nominal size. However, the polymer barrel is not suitable for high-pressure syringe pump use and has greater oxygen permeability than glass; oxygen transmission rate is approximately 0.5 cm³/(m²·day·bar) for cyclic olefin polymer at 23 °C and 0% RH, while glass is effectively zero. For dry-powder, tablet, capsule, or granule APIs, the cartridge assembly is not an appropriate primary package because it lacks powder-filling geometry, desiccant integration, or oral-dosing interfaces. If an oral or injectable API is formulated as a solution, suspension, or emulsion, the cartridge can serve as a dose reservoir in pen-injector research configurations, but the closure and needle interface are optimized for parenteral administration rather than oral liquid dispensing.
| Parameter | NEST polymer cartridge | Type I glass cartridge |
|---|---|---|
| Nominal fill volume | 1.5 mL, 3.0 mL | 1.5 mL, 3.0 mL |
| Barrel material | Cyclic olefin polymer | Borosilicate glass |
| Break-loose force after 14 days | 12 N to 20 N | 8 N to 15 N |
| pH shift in alkaline media | Not detected | Possible above pH 8.0 |
| Oxygen transmission rate at 23 °C | 0.5 cm³/(m²·day·bar) | 0 cm³/(m²·day·bar) |
| Drop resistance | No breakage at 1.5 m | Breakage possible |
| High-pressure syringe pump use | Not recommended above 40 N | Possible up to 100 N |
Compliance of the assembly is verified according to the test matrix below. Acceptance values are batch release or qualification criteria, not clinical limits.
| Requirement | Standard / test method | Acceptance criterion |
|---|---|---|
| Plastic packaging system | USP <661.1> | Physicochemical tests per monograph |
| Elastomeric closures for injections | USP <381> | Meets monograph requirements |
| Particulate matter for injections | USP <788> | ≤ 6000 particles per container ≥ 10 µm; ≤ 600 per container ≥ 25 µm |
| Subvisible particles for protein formulations | USP <787> | Per formula-specific limit |
| Bacterial endotoxins | USP <85> | ≤ 0.25 EU/mL extractable |
| Container closure integrity | USP <1207> | No leak above 0.05 µm equivalent |
| Dimensional envelope | ISO 11608-3:2022 | Conform to pen platform drawings |
| Primary packaging GMP | ISO 15378:2017 | Quality system certified |
| Biological reactivity | ISO 10993-5:2009, ISO 10993-10:2010 | No cytotoxic or irritation response |
| Distribution testing | ASTM D4169-22 | Assurance level II |