Products

Lithium aluminum deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: Lithium aluminum deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@sinochem-nanjing.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 486874
    Product Name Lithium Aluminum Deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    Chemical Name Lithium aluminum deuteride
    Synonyms LiAlD4; Lithium aluminium deuteride
    Cas Number 14128-54-2
    Molecular Formula LiAlD4
    Molecular Weight 41.98 g/mol
    Appearance White to gray crystalline powder or solid
    Assay ≥98%
    Isotopic Purity ≥99 atom % D
    Grade Pharma Grade
    Product Type Pharmaceutical API
    Dosage Forms Tablet, Capsule, Granule, Injection
    Routes Of Administration Oral, Injectable
    Solubility Reacts with water; soluble in ethers such as THF and diethyl ether
    Melting Point Decomposes above 125 °C
    Density 0.917 g/cm³ at 25 °C
    Storage Conditions Store in a cool, dry, inert atmosphere; protect from moisture and air
    Packaging Sealed containers under inert gas
    Shelf Life 24 months when stored properly
    Hazard Classification Water-reactive, flammable solid
    Usage Reducing agent and deuterium source
    Incompatibilities Water, acids, oxidizers, alcohols
    Handling Precautions Handle under inert gas; avoid moisture and ignition sources

    As an accredited Lithium aluminum deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Lithium aluminum deuteride Pharma Grade API: 1 kg sealed, argon-filled glass bottles, moisture-barrier foil pouches, desiccant, hazardous labels for oral/injectable use.
    Container Loading (20′ FCL) 20′ FCL container loading for Lithium aluminum deuteride Pharma Grade API, suitable for tablets, capsules, granules, oral and injectable pharmaceuticals, securely packed.
    Shipping Lithium aluminum deuteride Pharma Grade API ships as a hazardous, water-reactive flammable solid (typically UN 1410, Class 4.3, PG I). Use sealed, moisture-proof, UN-approved packaging under inert atmosphere. Label per IATA/IMDG/ADR, avoid moisture, heat, and ignition. Transport via approved dangerous-goods channels with full documentation and temperature control if required.
    Storage Store in a cool, dry, well-ventilated, fire-resistant area away from heat, sparks, open flames, water, acids, alcohols, oxidizers, and incompatible materials. Keep containers tightly closed under inert gas (nitrogen or argon), protected from moisture and light. Maintain controlled room temperature or refrigerated conditions as per label; segregate from combustible materials. Use explosion-proof equipment and grounded containers.
    Shelf Life Shelf life is manufacturer-assigned; typically 24–36 months if unopened and stored dry, sealed, under inert gas, protected from moisture; retest after opening.
    Application of Lithium aluminum deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    During scale-up of a deuterated primary amine hydrochloride for an oral capsule line, the nitrile precursor is reduced with pharma-grade LiAlD4 in diethyl ether rather than tetrahydrofuran because the subsequent API retains less ethereal solvent under tray drying at 35–40 °C and 10–20 mbar. The substrate is dissolved at 0.45–0.55 mol/L, and LiAlD4 is charged as a 1.0 mol/L ethereal slurry in four equal portions over 90 min while the jacket is held at −28 °C to −22 °C. Reverse-phase HPLC with UV detection at 254 nm is used to monitor nitrile consumption; if unreacted nitrile peak area remains above 2.0%, a second portion of 0.10 mol LiAlD4 per mol nitrile is added. The Fieser quench uses water, 15% NaOH, and water in 1:1:3 weight ratio relative to LiAlD4 input, keeping internal temperature below 10 °C. The resulting amine is extracted into methyl tert-butyl ether, washed with brine, and acidified with ethanolic HCl to precipitate the hydrochloride. Residual deuterium incorporation at the α-methylene carbon is quantified by 2H NMR per USP <761> and is specified at not less than 98.5 atom% D. Capsule filling is conducted on a dosator-type machine at 60,000 capsules/h with fill weight target 225 mg ±5%; powder blend uniformity is tested per USP <905> with acceptance value ≤ 15.

    Deuterated Carbinol Intermediate Synthesis for Sustained-Release Tablet APIs

    In the registered synthesis of a deuterated diaryl carbinol intermediate for a once-daily tablet product, LiAlD4 is charged into anhydrous tetrahydrofuran under nitrogen at a reactor jacket setpoint between −10 °C and 0 °C. The substrate is an ethyl ester; the reducing agent is introduced as a 1.0 mol/L solution in tetrahydrofuran via a peristaltic pump with a mass-flow-calibrated addition rate of 0.8–1.2 mL/min/kg substrate. The ester-to-hydride molar ratio is maintained between 1.00:0.32 and 1.00:0.50 to limit over-reduction of the aryl chloride ring. After 1.5–3.0 h at an internal temperature of −5 °C to 5 °C, the reaction is quenched by sequential addition of water, 15% NaOH, and water in the weight ratio 1:1:3 relative to LiAlD4. The resulting deuterated carbinol is extracted into methyl tert-butyl ether and concentrated under vacuum 20–30 mbar. The isolated intermediate is then used in the downstream coupling step to form a deuterated ester prodrug. For tablet processing, the finished deuterated API is milled through a conical mill equipped with a 0.500 mm screen; particle size distribution is controlled to d90 ≤ 250 µm by laser diffraction per USP <429>. Compression is performed on a 27-station rotary tablet press at 35–45 rpm with main compression force between 12 kN and 22 kN. Tablet hardness is measured per USP <1217> to maintain friability below 1.0%, and disintegration is tested per USP <701> at 37 ± 2 °C with a limit of ≤ 15 min. Release testing includes residual tetrahydrofuran by headspace GC-FID per USP <467>, with acceptance limit not more than 720 ppm for the ICH Q3C Option 1 daily dose assumption of 10 g.

    Why Anhydrous Quench Design Determines Injectable-Grade Purity

    Injectable-grade purity in the reduction of a deuterated secondary alcohol requires quench design that excludes protic water; the ketone substrate is charged into a 50 L Hastelloy C22 reactor as a 0.35 mol/L solution in anhydrous tetrahydrofuran and cooled to −20 °C. LiAlD4 is added as a 1.0 mol/L tetrahydrofuran solution at 0.50 mol per mol ketone; the half-molar charge leaves an excess deuteride pool that scavenges adventitious moisture while keeping the reaction endpoint stable. The internal temperature is kept below −15 °C throughout the addition because higher temperatures accelerate solvent ring-opening by aluminium species and increase the formation of non-isotopic side products. Quench is performed with deuterium oxide rather than water; the D2O volume is 1.0 mL per gram of LiAlD4, added over 45 min through a cooled dropping funnel to keep internal temperature below 5 °C. This is followed by 15% NaOD in D2O in the same 1:1:3 weight ratio. The biphasic mixture is filtered through a jacketed Nutsche filter with 0.2 µm in-line membrane and the organic phase is concentrated under 20–30 mbar. The final injectable API is lyophilized from a tert-butanol/water mixture; the lyophilizer shelf ramp is −40 °C to 25 °C over 24 h at 80–120 µbar. Residual water by Karl Fischer per USP <921> is ≤ 1.0%. Particulate matter is tested per USP <788> for a small-volume injection; acceptance is ≤ 6,000 particles per container at 10 µm and ≤ 600 particles per container at 25 µm. Residual aluminium is controlled by ICP-MS per USP <233> using an internal procedure limit justified by the clinical toxicology package because ICH Q3D does not assign an aluminium PDE.

    Where the finished dosage form is a deuterated amine hydrochloride in a sachet or granule, the amide precursor is reduced under high dilution in a THF/toluene mixture. The amide substrate is charged at 0.30 mol/L, and LiAlD4 is added in three half-portions over 90 min at 0 °C to 5 °C. Reaction calorimetry with a Mettler-Toledo RC1e indicates adiabatic temperature rise below 45 °C for the half-maximum conversion. After distillation of tetrahydrofuran and replacement with toluene, the reaction is quenched with 2 mol/L HCl and the aqueous layer is basified to pH 11.5–12.0 with 30% NaOH. The amine is extracted into dichloromethane and azeotropically dried. Granulation of the final deuterated API is performed in a high-shear mixer with impeller speed 250 rpm and chopper 1,500 rpm; granulation liquid is 8–10 wt% water. The wet mass is dried in fluid bed at inlet air 60–70 °C until a loss on drying of 2.0–3.0% is achieved. Granules are sieved through a 1.0 mm screen and blended with colloidal silicon dioxide at 0.5 wt%.

    When an Acid Chloride Feedstock Is Reduced to a Deuterated Primary Alcohol for Oral Solution APIs

    Acid chlorides are reduced to deuterated primary alcohols in the same reactor train used for ester reductions; no specialised equipment is required beyond a nitrogen-purged charging lance, so the expansion of scope to oral solution intermediates is limited to solvent exchange and a single vacuum distillation step at 25–35 mbar. Published data for this specific configuration is limited; the condition relies on the analogous acid chloride reduction behaviour of LiAlH4, with deuterium incorporation measured by 2H NMR per USP <761>.

    Following reverse-phase purification of the isotopically labelled intermediate, the same residual solvent test methodology is applied across tablet, capsule, granule, and injectable finishing lines; release ceilings differ by route and dosing assumption. The concentration limits below are derived from ICH Q3C Option 1 based on a 10 g daily dose; lower daily doses allow proportionally higher limits according to the permitted daily exposure equations.

    Dosage formResidual solventICH Q3C limitTest method
    Oral tabletTetrahydrofuran720 ppmHeadspace GC-FID per USP <467>
    Oral capsuleDiethyl ether5000 ppmHeadspace GC-FID per USP <467>
    Oral granuleToluene890 ppmHeadspace GC-FID per USP <467>
    Small-volume injectableAcetonitrile410 ppmHeadspace GC-FID per USP <467>
    Free Quote

    Competitive Lithium aluminum deuteride Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Lithium aluminum deuteride (CAS 14128-54-2; LiAlD4; molecular weight 41.98 g mol−1) is supplied as a pharmaceutical-grade deuteride-transfer reagent for active pharmaceutical ingredient synthesis. Catalogue designations that include tablet, capsule, granule, oral, or injectable presentations refer to the deuterated drug substances obtained after reduction and purification, not to direct use of the reagent in a dosage form. The compound is an off-white to gray, moisture-sensitive solid requiring inert-atmosphere handling. No harmonized pharmacopoeial monograph exists; supplier model codes such as LAD-PG-98.0 or LAD-PG-98.5 are used, with the numeric suffix indicating the minimum isotopic enrichment of 98.0 atom % D or 98.5 atom % D. Published data for a specific pharma-grade lithium aluminum deuteride configuration is limited, so release criteria should be established from supplier qualification and process validation under ICH Q7.

    Because the material is a reducing agent and not a conventional API, qualification focuses on critical quality attributes that affect downstream deuterium incorporation and impurity carryover. Residual protium carriers, residual solvents, lithium and aluminum impurities, and moisture can reduce effective deuteride content and alter the isotopic purity of the final API. Incoming material is tested against supplier-validated limits and retained for batch traceability under 21 CFR 211.160 and ICH Q7.

    Why Is Direct Formulation of Lithium Aluminum Deuteride in Oral and Injectable Dosage Forms Contraindicated?

    Lithium aluminum deuteride is not a final API and cannot enter tablet, capsule, granule, or injectable formulations directly. The compound reacts violently with water, alcohols, and carboxylic acids; contact with aqueous gastric fluid or a Water for Injection vehicle would generate heat and hydrogen isotopes. In a manufacturing setting, this reactivity requires storage in a nitrogen-filled glovebox with oxygen below 0.5 ppm and moisture below 0.5 ppm, and transfer through PTFE or stainless-steel lines. These constraints conflict with aqueous granulation, direct compression at ambient humidity, and aseptic filling of aqueous solutions.

    The final deuterated API, not LiAlD4, enters dosage forms. For oral and injectable products, residual Li+, Al3+, and deuterated solvents are controlled in the drug substance. Direct compression and aqueous granulation are applied only after the reagent has been removed by quench, extraction, crystallization, and drying.

    In a GMP synthesis for a tablet or capsule API, LiAlD4 is metered as a solid from a loss-in-weight feeder under a nitrogen sweep or as a solution in tetrahydrofuran into a jacketed vessel. Wetted surfaces are Hastelloy C22, borosilicate glass, or PTFE to minimize metal-catalysed decomposition. The addition temperature is maintained between −10 °C and 10 °C for most carbonyl reductions; process calorimetry is used to detect accumulation. Engineering assessments of analogous LiAlH4 reductions indicate that a delay between reagent addition and observed exotherm can occur when the first portion reacts slowly, creating an accumulation hazard. The same risk applies to LiAlD4 because deuteride transfer is not kinetically identical to hydride transfer. No universal conversion factor can be applied across substrates.

    Reaction calorimetry on LiAlD4 reductions shows that initial heat release may be delayed by an initiation period. In a jacketed reactor, controlled addition is set so that the exotherm remains within jacket cooling capacity. For analogous LiAlH4 systems, the main heat release is attributed to reduction and subsequent quench. The deuterated analogue is expected to exhibit a measurable but route-dependent kinetic isotope effect because the force constants of Li–D and C–D bonds differ from Li–H and C–H. Scale-up therefore requires adiabatic calorimetry screening and a worst-case accumulation test.

    After quench, the product is isolated and assayed. Deuterium incorporation is measured by 2H NMR or by the decrease in 1H NMR integration at the position of interest. A 600 MHz NMR spectrometer is commonly used for structural assignment; quantitative NMR requires a relaxation delay sufficient for the nuclei of interest. The final API is then purified by crystallization or preparative chromatography before blending or granulation.

    For tablet and capsule forms, the purified deuterated API is blended in a bin blender or high-shear granulator. Blend uniformity is assessed by USP <905>. Granule production may use dry granulation or wet granulation with water-miscible binders if the final API is stable. Lubrication is performed with magnesium stearate at levels established by qualification; particle size of the final API is controlled by laser diffraction per ISO 13320:2020, and milling is carried out in a nitrogen-inerted cone mill where necessary to protect labile isotope positions. For injectable forms, the purified API is dissolved in Water for Injection, filtered through a 0.22 µm sterilizing-grade filter, and aseptically filled in an ISO 14644-1 Grade A zone.

    When Tablets, Capsules, Granules, or Injections Require a Deuterated Active Intermediate

    LiAlD4 is selected when the synthetic route requires deuterium incorporation at a reducible carbon. The reagent transfers deuteride to aldehydes, ketones, carboxylic acids, esters, amides, nitriles, and epoxides. This functional-group scope is a key difference from sodium borodeuteride, which reduces aldehydes and ketones cleanly but does not reduce simple esters or amides under standard conditions. Consequently, LiAlD4 allows introduction of carbon-bound deuterium at a carboxylic acid carbon during reduction to a primary alcohol, while NaBD4 would not reduce the same substrate without activation.

    Another difference is handling severity. LiAlD4 requires strict aprotic conditions and controlled quenching; NaBD4 can often be handled in alcoholic solvents with slower solvent decomposition, but the protic solvent may erode isotope enrichment through proton exchange. Deuterium gas with a palladium or platinum catalyst saturates C=C bonds and can exchange aromatic C–H positions, but it does not reduce a ketone to a deuterated alcohol. Deuterium oxide exchanges O–H, N–H, and enolizable C–H positions but produces labels that can be labile in biological systems and during analyte workup.

    The following comparison summarizes practical distinctions.

    Deuterium source Typical reduction scope Deuterium position Operational boundary
    Lithium aluminum deuteride Aldehydes, ketones, carboxylic acids, esters, amides, nitriles, epoxides Carbon at reduced electrophile Anhydrous aprotic solvent; exothermic quench; air/moisture exclusion
    Sodium borodeuteride Aldehydes, ketones, imines; limited ester/amide reduction Carbon at aldehyde/ketone carbonyl Controlled protium-free quench; may tolerate alcoholic solvents under specified conditions
    Deuterium gas with Pd, Pt, or Raney Ni Alkene/alkyne saturation; exchange of selected C–H positions Olefinic carbon or exchangeable C–H Catalyst-specific pressure and temperature; catalyst removal
    Deuterium oxide O–H, N–H, and enolizable C–H exchange Exchangeable positions pH and temperature control; label can be labile in vivo

    The selection of deuterium source must be confirmed by a compatibility study using the actual API intermediate. Process analytical technology may include in-situ FTIR or Raman spectroscopy to track reduction when the carbonyl band is resolved. A specific LiAlD4-mediated reduction should be verified under the intended GMP conditions because trace moisture, solvent, and mixing geometry affect rate and impurity profile. Carbon-bound deuterium introduced by LiAlD4 is generally retained through crystallization and lyophilization, but later hydrogenation or metal-catalysed exchange can erase it.

    Pharmaceutical-grade lithium aluminum deuteride release specifications are derived from risk assessment because no pharmacopoeial monograph exists. A certificate should include appearance, isotopic enrichment, chemical purity by hydride content, residual solvents, and elemental impurities. Tetrahydrofuran, a Class 2 solvent under ICH Q3C, has a permitted concentration limit of 720 ppm and a daily permitted exposure of 7.2 mg/day. Residual THF is measured by headspace gas chromatography per USP <467>. Elemental impurities are measured by ICP-MS and controlled against ICH Q3D. The absence of a direct monograph requires the user to establish acceptance criteria from batch data; a supplier certificate is not sufficient to waive incoming identity and purity testing under 21 CFR 211.160.

    Hydride content may be measured by gas volumetric assay after treating the material with a controlled isopropanol-water mixture. A representative release criterion is not less than 95.0% hydride content and 98.0 atom % D isotopic enrichment, but other supplier grades may specify 99 atom % D for high-specificity APIs. Trace lithium and aluminum species are controlled because they can precipitate or complex with the final drug substance during workup. Moisture is a critical rejection parameter; containers with headspace moisture above 0.5 ppm should not be used in a validated GMP campaign without re-drying and supplier reassessment.

    Batch Release Parameters and Pharmacopoeial Method Alignment

    For incoming pharmaceutical-grade LiAlD4, the following quality elements are recommended for a batch release matrix. The limits shown are typical or regulatory-derived and must be replaced by supplier-validated numbers for the actual product code and dosage form.

    Quality attribute Method or standard Typical limit
    Appearance Visual inspection against supplier reference Off-white to gray powder; no hard agglomerates
    Isotopic enrichment Quantitative 2H NMR; USP <761> framework ≥ 98.0 atom % D
    Hydride content Gas volumetric assay after isopropanol quench ≥ 95.0%
    Residual tetrahydrofuran Headspace GC; USP <467>; ICH Q3C Class 2 ≤ 720 ppm
    Elemental impurities ICP-MS; ICH Q3D Class 1 elements within daily intake limits
    Headspace moisture Moisture sensor on sealed container ≤ 0.5 ppm before opening
    Particle size Laser diffraction ISO 13320:2020 under inert dispersion Supplier-validated range; no official monograph for LiAlD4 itself

    For oral solids, the final deuterated drug substance is sized, blended, and compressed. Disintegration testing follows USP <701>, and dissolution testing follows USP <711>. Capsule filling may use a tamping-pin or dosing-disc machine; mass uniformity is assessed by USP <905>. Granule formulations are dried to a loss-on-drying limit established by stability data, and residual water is measured by Karl Fischer titration per USP <921> Method Ia where the final API is not water-reactive. The reagent LiAlD4 remains upstream; no residual reactive deuteride should be present in the final drug product, and absence is confirmed by a suitable method during release.

    For injectable presentations, the purified deuterated API is dissolved in Water for Injection, filtered through a 0.22 µm sterilizing-grade filter, filled into depyrogenated vials, and lyophilized where stability requires. Lyophilization cycle parameters are based on thermal characterization by differential scanning calorimetry and freeze-drying microscopy. The final cake is tested for reconstitution time, residual moisture, and particulate matter per USP <788> and USP <790>. The deuterium label at carbon is not affected by lyophilization, but residual moisture in the lyophilized cake must be controlled below the stability limit established for the specific product.

    Top