Products

ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 347766
    Product Name ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    Product Category Pharmaceutical-grade active pharmaceutical ingredient
    Grade Pharma Grade
    Dosage Forms Tablet, Capsule, Granule, Injection
    Routes Of Administration Oral, Injectable
    Packaging Type ECO LITE drums
    Packaging Material High-density polyethylene (HDPE)
    Packaging Closure Tamper-evident lid with gasket
    Packaging Capacity Available in multiple drum sizes
    Compliance GMP, USP, EP, JP, ICH Q7
    Sterility Non-sterile or sterile options available
    Storage Conditions Cool, dry, protected from light and moisture
    Shelf Life As per certificate of analysis
    Documentation COA, MSDS, DMF available
    Customization Custom labels, liners, and packaging configurations available

    As an accredited ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaging: 25 kg ECO LITE drums, securely lined, suitable for pharma-grade API in tablets, capsules, granules, oral and injectable forms.
    Container Loading (20′ FCL) 20′ FCL loaded with ECO LITE drums of Pharma Grade API for tablets, capsules, granules, oral and injectable use; securely stowed.
    Shipping ECO LITE drums are securely sealed, labeled, and palletized under cGMP/GDP conditions. Pharma-grade API is protected from moisture, contamination, and temperature excursions, with full documentation and traceability. Shipped by road, sea, or air with temperature-controlled options; classification follows SDS/UN requirements. Customs and international regulatory paperwork included.
    Storage Store ECO LITE drums of Pharma Grade API in a cool, dry, well-ventilated, clean area away from direct sunlight, heat, moisture, and incompatible substances. Keep drums tightly closed, undamaged, and upright. Maintain controlled room temperature (15–25°C) unless the certificate of analysis specifies otherwise. Follow cGMP, FIFO/FEFO, and spill-control procedures to preserve quality for oral and injectable use.
    Shelf Life Typically 24–36 months when stored sealed in original ECO LITE drums under recommended conditions, per supplier stability data and retest date.
    Application of ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    When direct compression is selected for oral solid-dose manufacture, the milled ECO LITE Pharma Grade API is first screened through 0.5 mm or 0.8 mm mesh and characterised under USP <616>, USP <1174>, and USP <786> for bulk density, flow, and particle size distribution before dispense. The addition ratio is not an intrinsic constant; it is derived from the approved unit dose and core tablet mass. For a 200 mg core carrying 25 mg active, the API contributes 12.5% w/w; for a 5 mg dose in a 250 mg core, the API contributes 2.0% w/w. Industrial direct compression lines handle API fractions commonly between 2% w/w and 70% w/w, but below 2% w/w segregation risk rises sharply when the API-to-excipient particle size ratio exceeds 5:1 or when bulk density differs by more than 0.20 g/cm³. The dry blend is prepared in a 600 L bin blender at 10 rpm for 15–25 min with geometric pre-blending at 1:10 ratio for low-dose intermediates, followed by lubrication with 0.5% w/w magnesium stearate for 3–5 min. Compression is performed on a rotary tablet press equipped with B-tooling or D-tooling; a 47-station press using 12 mm round tooling typically operates at 45–60 rpm with pre-compression force 2–4 kN and main compression 8–15 kN. Production-scale failure modes are observed when tablet friability exceeds 1.0% w/w under USP <1216>, which correlates with capping at compact tensile strength above 200 MPa when binder concentration is below 1.5% w/w and moisture is below 1.5% w/w. Dissolution is controlled under USP <711>, content uniformity under USP <905>, and release is performed under FDA 21 CFR 211.110; elemental impurities are assessed under ICH Q3D, and residual solvents under ICH Q3C. Terminal finished dosage forms are uncoated immediate-release tablets, film-coated tablets, and scored tablets for oral administration.

    What limits content uniformity when an API is dry-blended below 5% w/w?

    Low-dose capsule filling from dry blends is sensitive to the same segregation mechanisms observed in direct compression, but the absence of compaction makes end-terminal blend uniformity the critical release criterion before encapsulation. The addition ratio is governed by unit dose and capsule fill weight rather than by the API grade; for a size 3 HPMC capsule filled to 180 mg, a 10 mg active represents 5.6% w/w, while a 1 mg active in a 120 mg fill represents 0.83% w/w. When active content falls below 2% w/w, the process requires geometric dilution in a 1:10 staged pre-blend, final blending in a 600 L bin blender at 10–12 rpm for 15–25 min, and in-line near-infrared uniformity verification at 10 sampling locations with acceptance of relative standard deviation ≤ 5.0%. Encapsulation is conducted on a dosator or tamping-pin machine with production rates up to 150,000 capsules/h; filled weight acceptance under USP <905> is ± 10% of target for individual units with relative standard deviation ≤ 5.0%. Powder bridging and rat-holing occur when bulk density falls below 0.40 g/cm³ or when Carr index under USP <1174> exceeds 25; such batches are re-worked only after re-milling through a 0.5 mm screen and renewed uniformity testing. Dissolution is controlled under USP <711>, microbial quality under FDA 21 CFR 211.113, elemental impurities under ICH Q3D, and residual solvents under ICH Q3C. Terminal finished dosage forms are hard gelatin or HPMC capsules intended for immediate-release oral administration.

    High-shear wet granulation endpoint control on a 600 L mixer with aqueous binder addition

    High-shear wet granulation is introduced when direct compression cannot accommodate a fine-milled API fraction below 50 µm, when bulk density must exceed 0.60 g/cm³ for high-speed filling, or when flow of the dry blend is insufficient under USP <1174>. The API addition ratio in the dry granulation charge may range from 2% w/w to 50% w/w; for a 250 mg tablet carrying 50 mg active, the API fraction is 20% w/w. ECO LITE Pharma Grade API is dry-mixed with binder-filler excipients for 5 min at impeller speed 100–150 rpm, after which purified water or binder solution is added at 20–35% w/w of dry mass over 2–4 min. The chopper is operated at 1500–3000 rpm during wet massing, which lasts 2–5 min; endpoint is monitored by impeller power draw and torque curves, with a 20–30% power increase from the dry baseline typically indicating satisfactory densification, whereas a plateau or decline after peak indicates overwetting. The wet mass is milled through a 1.0 mm screen and dried in a fluid-bed dryer at inlet air temperature 60–70°C until loss on drying reaches 1.5–2.5% w/w. Dried granules are milled through a 0.8 mm screen, lubricated with 0.5% w/w magnesium stearate for 3 min, and compressed or encapsulated. Overwetted batches with final loss on drying above 3.0% w/w show picking and sticking on tablet presses; under-dried batches below 1.0% w/w generate excessive fines below 75 µm and cause weight variation under USP <905>. Compliance is maintained under USP <786> for granule particle size, USP <711> for dissolution, ICH Q3C for residual solvents, ICH Q3D for elemental impurities, and FDA 21 CFR 211.110 for in-process potency and uniformity. Terminal finished dosage forms are immediate-release tablets, film-coated tablets, capsules, and oral granules in sachets.

    Control parameterDirect compressionDry granulation / roller compactionHigh-shear wet granulation
    Bulk density after processing0.45–0.60 g/cm³0.55–0.70 g/cm³0.50–0.75 g/cm³
    Moisture content before compression≤ 2.0% w/w≤ 2.5% w/w1.5–2.5% w/w
    Typical API loading in dry mass2–70% w/w5–60% w/w2–50% w/w
    Uniformity testUSP <905>USP <905>USP <905>
    Primary process riskSegregation when PSD mismatch exceeds 5:1Ribbon splitting when density exceeds 1.3 g/cm³Overwetting with loss on drying above 3% w/w

    Roller compaction replaces aqueous granulation when the API is incompatible with 2% w/w or greater water exposure, or when fluid-bed drying at 60–70°C produces degradation products above the qualification threshold under ICH Q3B. The addition ratio in the roll-compacted dry granulation route may span 5% w/w to 60% w/w of the dry blend; for a 150 mg tablet carrying 25 mg active, the API fraction is 16.7% w/w. ECO LITE Pharma Grade API is blended with filler, dry binder, and half of the total lubricant at 0.5% w/w before being passed through a roller compactor with 100 mm rolls at roll pressure 4–6 MPa and gap 2–4 mm; ribbon density is maintained between 1.0 g/cm³ and 1.2 g/cm³ because higher density produces hard granules that resist compression and slow release under USP <711>. The ribbons are milled through a 1.0 mm screen, re-blended with the remaining lubricant for 3 min, and compressed or encapsulated. Finished products are tested under USP <616> for bulk and tapped density, USP <905> for uniformity, USP <711> for dissolution, ICH Q1A for stability, and FDA 21 CFR 211.110 for in-process control. Published data specific to ECO LITE Pharma Grade API in this exact configuration is limited; process windows must be confirmed by development batches under ICH Q1A. Terminal finished dosage forms are immediate-release tablets, capsules, and granule-filled sachets for oral administration.

    When thermostable injectable solutions are aseptically filled, sterility and endotoxin limits govern line release

    Injectable-grade application requires the API to meet USP <85> bacterial endotoxins, USP <71> sterility, USP <788> particulate matter, USP <381> elastomeric closure compatibility, and ICH Q3D elemental impurities before aseptic processing. The addition ratio in aseptic liquid filling is expressed as concentration rather than mass percent; ECO LITE Pharma Grade API is dissolved in Water for Injection to a concentration determined by the approved finished product specification, commonly between 1 mg/mL and 100 mg/mL when the fill volume is 1–10 mL, but no fixed concentration can be assigned without the approved common technical document. The compounding vessel is a closed 316L stainless steel tank maintained in an ISO 14644-1:2015 Grade C environment; dissolution proceeds at 20–25°C with agitation at 200–400 rpm, and pH is adjusted to 5.5–7.0 with 0.1 N hydrochloric acid or sodium hydroxide. The solution is passed through a 0.22 µm PVDF or PES membrane filter; filter integrity testing must meet the membrane manufacturer’s minimum bubble point, typically ≥ 3.0 bar for PVDF at 23°C. Filling is conducted in Grade A unidirectional airflow with Grade B background under EU GMP Annex 1; fill volume accuracy is maintained at ± 2.0% for volumes above 2 mL with in-process weight checks every 15 min. Terminal sterilisation in an autoclave at 121°C for 15 min is limited to heat-stable formulations; heat-labile liquids are aseptically filled without terminal sterilisation, requiring additional media-fill and operator monitoring under FDA 21 CFR 211.113 and EU GMP Annex 1. Operational boundaries include avoidance of silicone oil from prefilled syringe components, which raises subvisible particle counts under USP <788>, and selection of closures with low extractables under USP <381>. Terminal finished dosage forms are single-dose or multi-dose vials, ampoules, and prefilled syringes for intravenous, intramuscular, or subcutaneous administration.

    Sterile injectable parameterMethodTypical acceptance limit
    SterilityUSP <71> / Ph. Eur. 2.6.1No growth after 14 days
    Bacterial endotoxinsUSP <85> / Ph. Eur. 2.6.14≤ 0.25 EU/mg depending on route
    Subvisible particulate matterUSP <788> / Ph. Eur. 2.9.19For ≥ 2 mL: ≤ 6000 particles ≥ 10 µm and ≤ 600 particles ≥ 25 µm per container
    Water content for lyophilisatesUSP <921> / Ph. Eur. 2.5.12≤ 3.0% w/w
    Filter integrityManufacturer bubble point or pressure decayMinimum bubble point per membrane type

    Freeze-drying is selected when aqueous solution stability data under ICH Q1A show assay loss exceeding 2.0% at 25°C over 6 months, because aseptic liquid filling alone does not provide sufficient storage stability. The pre-lyophilisation solution is compounded with ECO LITE Pharma Grade API at 5 mg/mL to 50 mg/mL; bulking agents such as mannitol or sucrose are added at 2% w/v to 5% w/v to provide cake structure and collapse resistance. The solution is pH-adjusted, filtered through a 0.22 µm membrane, and filled into Type I borosilicate glass vials to 2–10 mL nominal volume. Lyophilisation is carried out with shelf temperature ramped from -40°C to +25°C under chamber pressure 50–150 µbar; primary drying times range from 24 h to 72 h depending on fill depth and product temperature, which is monitored by thermocouple and Pirani gauge. Cake collapse occurs when product temperature exceeds the formulation collapse temperature by more than 1°C; therefore, shelf ramp is limited during primary drying and adjusted after the Pirani-to-thermocouple pressure differential indicates sublimation end. Residual moisture is controlled at ≤ 3.0% w/w under USP <921> or Ph. Eur. 2.5.12, and the reconstituted solution must be free of visible particulates under USP <790> and subvisible particulates under USP <788>. Sterility is validated under USP <71> and EU GMP Annex 1 aseptic simulation, endotoxin under USP <85>, and container closure integrity under USP <1207>. Terminal finished dosage forms are sterile lyophilised powders for reconstitution with Water for Injection or 0.9% w/w sodium chloride injection, intended for intravenous, intramuscular, or subcutaneous administration.

    Free Quote

    Competitive ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    ECO LITE drums Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable are specified as intermediate bulk containers for active pharmaceutical ingredients that are subsequently processed into tablet, capsule, granule, injection, oral, and injectable dosage forms. The drum model is selected by nominal filling volume, closure type, and liner grade; the available open-head configurations are 30 L, 60 L, 120 L, and 200 L, while tight-head configurations are supplied in 60 L and 120 L with 2-inch and 3/4-inch bungs. The body is rotationally moulded from high-density polyethylene, and the top chime is designed for a lever-lock ring with an EPDM gasket. A PTFE-lined cap is specified when the API or granulating solvent contains methylene chloride, dimethyl sulfoxide, or N-methyl-2-pyrrolidone. The drum is not a sterile primary package; it is an intermediate container that must be discharged in a classified area appropriate to the downstream unit operation.

    What specification set governs the ECO LITE drum shell, liner, and closure system?

    The HDPE shell is assessed under 21 CFR 177.1520 for olefin polymers used in contact with food, and under USP <661.1> and USP <661.2> for plastic packaging systems for medicinal products. The polyolefin resin and antioxidant/slip additive package are tested against Ph. Eur. monographs 3.1.3 and 3.1.5. Extractables screening follows USP <1663> and USP <1664> when the drum is intended to contact a solvent-rich API slurry or a granulating solvent; published data for this specific configuration is limited, and the certificate of analysis must be matched to the solvent system. The drum supplier maintains ISO 15378:2017 certification for primary packaging materials for medicinal products, and the receiving site verifies each lot against the supplier's declaration of compliance. Migration limits are applied according to EC 10/2011 at 10 mg/dm² overall migration for the polymer body, but pharmaceutical applications require additional extractables data because the contact area-to-volume ratio differs from food packaging assumptions.

    Representative dimensional values for ECO LITE open-head configurations
    ModelNominal capacityTop outside diameterOverall heightSidewall thicknessTare massMaximum gross mass
    ECO LITE 3030 L310 mm500 mm1.8 mm to 2.0 mm2.4 kg35 kg
    ECO LITE 6060 L400 mm600 mm2.0 mm to 2.5 mm4.3 kg65 kg
    ECO LITE 120120 L500 mm800 mm2.5 mm to 3.0 mm7.5 kg125 kg
    ECO LITE 200200 L580 mm950 mm3.0 mm to 3.5 mm10.8 kg210 kg

    Values are representative only; the supplier drawing for each model suffix is the controlling document. Tight-head models have the same body diameters but reduced overall height because of the top chime configuration.

    For tablet and capsule granulation, the drum receives milled or granulated API from a conical mill or fluid-bed dryer. The product-contact interior is specified to avoid plasticiser migration that could alter blend potency or introduce extractable residues above 0.1 mg/day per USP <661.1> reporting threshold. Loading is performed through the open-head aperture with a 45° discharge cone; the 60 L drum accepts a standard 500 mm butterfly valve adapter for gravity transfer into a bin blender. The drum must be grounded during transfer because the HDPE surface can accumulate a surface charge above 10 kV in low-humidity granulation areas. A conductive black liner is specified when the API has a minimum ignition energy below 3 mJ, because the standard natural HDPE liner does not provide sufficient static decay. Granule-sized fractions with Hausner ratio above 1.4 require mechanical agitation during discharge, as the 45° cone may otherwise retain material.

    Moisture-sensitive APIs should be filled only after the drum is pre-dried at 50 °C for 4 h when the warehouse relative humidity exceeds 60 %. Oxygen transmission through the standard HDPE sidewall is measured by ASTM D3985-17 at 23 °C and 0 % RH; the value for a 2.0 mm wall is commonly 200 cm³/(m²·day·atm) to 400 cm³/(m²·day·atm). A metallised barrier liner reduces the oxygen transmission rate to 0.5 cm³/(m²·day·atm) to 2.0 cm³/(m²·day·atm). The liner is heat-sealed after nitrogen purging to maintain residual oxygen below 5 % in the headspace. This is relevant for oxidation-prone APIs with a peroxide impurity limit below 0.1 % per ICH Q3B.

    When injectable-grade APIs are filled for final sterile processing, which particulate and closure limits require verification?

    Injectable-grade API receives a higher level of container cleaning and particulate control than oral-grade API. Each drum is rinsed with 0.2 µm filtered demineralised water and dried with HEPA-filtered air at 40 °C for 30 min. The rinse water is sampled per 100 mL; acceptance is not more than 25 particles at ≥ 10 µm and not more than 3 particles at ≥ 25 µm per 100 mL, measured by light obscuration according to USP <788>. Closure integrity is tested on every filled drum with a pressure decay method: the drum is pressurised to 0.3 bar and held for 5 min; pressure loss greater than 0.01 bar is rejected. The EPDM gasket is not suitable for repeated autoclave exposure; it is replaced after every 10 use cycles or 24 months, whichever occurs first. Terminal sterilisation of the closed drum is not recommended because internal pressure during autoclave cycling can exceed the closure ring retention force and produce gasket blow-out.

    Cleaning and reuse constraints for the ECO LITE drum are determined by the residue risk of the previous API. For multi-product facilities, the drum is dedicated to a single API if the acceptable daily exposure of the previous compound is below 100 µg/day, because the HDPE wall can retain trace organic residues after three detergent wash cycles. Reuse for a different API is permitted only when a validated cleaning procedure with 0.5 % sodium hydroxide at 60 °C for 30 min, followed by 70 % isopropanol rinse, achieves not more than 10 ppm of the previous API in the final rinse. The lever-lock ring is disassembled for cleaning because product accumulates in the gasket groove. Gasket replacement is performed after any campaign involving a solvent with a Hansen solubility parameter hydrogen-bonding value greater than 8.0 (cal/cm³)^0.5, because solvent uptake can reduce gasket sealing force.

    Stack-load performance, pallet restraint, and drop-impact resistance

    Distribution testing is performed on drums filled to 98 % of nominal volume with a 50 % aqueous propylene glycol solution to avoid freezing at -10 °C. Free-fall drop impact according to ASTM D5276-19 is performed on the top chime, side seam, and bottom edge from 1.2 m for the 60 L drum and 0.8 m for the 200 L drum. The acceptance criterion is no leakage and no closure disengagement. Stack compression is evaluated by applying a static top load of 250 kg to the 60 L drum for 28 days at 40 °C; deformation of the closure ring seat must not exceed 2 mm. In distribution simulation according to ASTM D4169-22, distribution cycle DC 6, the pallet is constrained with 90 mm stretch film at 12 µm thickness and 200 % pre-stretch. A 3 x 2 pallet pattern is recommended for 60 L drums, and a 2 x 2 pattern for 120 L drums. Field failures observed on manufacturing lines commonly occur at the lever-lock ring when operators apply an off-axis pinch force during closure; torque wrenches are calibrated to 22 N·m to 25 N·m for the 60 L ring.

    Compliance checklist for the ECO LITE drum system
    Standard or regulationApplicationTest or limit
    21 CFR 177.1520HDPE body and linerOlefin polymer extraction limits
    USP <661.1>Plastic packaging systemPhysicochemical tests
    USP <661.2>Polyethylene resinExtractables and metals
    Ph. Eur. 3.1.3PolyolefinsAdditive migration limits
    Ph. Eur. 3.1.5Polyethylene with additivesSpecific additive limits
    EC 10/2011Overall migration10 mg/dm²
    ISO 15378:2017QMS for primary packaging materialsGMP principles
    ASTM D4169-22Distribution simulationDistribution cycle DC 6

    Compared with stainless steel drums, the ECO LITE drum eliminates the need for passivation and electropolishing, but it cannot be cleaned with hot nitric acid or steam at 121 °C in situ. Maximum continuous service temperature is 70 °C for aqueous systems and 50 °C for solvent systems; prolonged exposure to aliphatic hydrocarbons above 40 °C may cause environmental stress cracking. Compared with fibre drums, the HDPE sidewall has lower water vapour transmission, commonly 0.05 g/m²·day at 23 °C and 85 % RH for the standard wall thickness, but the exact value depends on the liner lot and should be confirmed by ASTM F1249-20. Unlike an open-head steel drum with a separate PE liner, the ECO LITE body does not have a metal chime that can corrode and shed iron particles into the API. The container is not intended for storage of strong oxidising acids, halogenated solvents above 40 °C, or amines that can promote environmental stress cracking in stressed HDPE regions.

    Top