Products

Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 562185
    Product Name Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    Product Category Pharmaceutical delivery device and Pharma Grade API formulation product
    Device Type Disposable pen injector
    Cartridge Capacity 3 ml
    Api Grade Pharma Grade
    Api Compatibility Tablet, Capsule, Granule, Injection
    Dosage Form Suitability Tablet, Capsule, Granule, Injection, Oral, Injectable
    Route Of Administration Oral and Injectable
    Administration Mechanism Pen injector with 3 ml cartridge
    Disposability Single-use disposable
    Sterility Sterile for injectable use; non-sterile for oral solid dosage use as applicable
    Material Of Construction Pharmaceutical-grade plastic and compatible elastomers
    Dose Delivery Accuracy Designed for accurate and consistent dose delivery
    Packaging Individual sterile barrier packaging for injectable configuration; regulated packaging for oral solid dosage forms
    Storage Conditions Store in a clean, dry, temperature-controlled environment per API and dosage form requirements
    Shelf Life Determined by API stability and packaged dosage form; typically 12 to 36 months
    Regulatory Compliance Manufactured in compliance with applicable pharmaceutical GMP standards
    Target User Pharmaceutical manufacturers, compounding pharmacies, and healthcare professionals
    Primary Use Delivery of Pharma Grade API in tablet, capsule, granule, oral, and injectable formats

    As an accredited Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Each carton contains one sterile, tamper-evident disposable pen injector with 3 ml cartridge, individually blister-packed and labeled for pharmaceutical use.
    Container Loading (20′ FCL) 20′ FCL container loading: secure, dry stowage of disposable pen injectors with 3 ml cartridges, pharma-grade API for oral/injectable use.
    Shipping Disposable pen injectors with 3 ml cartridges ship in temperature-controlled, tamper-evident, shock-resistant packaging to preserve sterility and API integrity. Cartridges remain secured in insulated coolers with temperature monitoring. Shipment includes SDS, CoA, packing list, and customs documentation. Handle upright; protect from light, moisture, and extreme temperatures; comply with IATA/ADR regulations.
    Storage Store in the original packaging in a clean, dry, well-ventilated area, protected from light, moisture, heat, and contamination. Maintain manufacturer-recommended temperature, typically 15–25°C unless otherwise specified; refrigerate injectable cartridges if required. Do not freeze. Keep upright, away from children, food, and incompatible materials. Do not use if damaged. Follow product label and safety data sheet.
    Shelf Life Shelf life varies by API and formulation; typically 24–36 months if unopened and stored as labeled, protected from light, heat, and moisture.
    Application of Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    Application dataset for the pharmaceutical-grade API is confined to six downstream manufacturing routes named in the material specification: direct compression tablets, hard capsules, oral granules, 3 ml cartridge aseptic filling for disposable pen injectors, lyophilized injection powder, and fast-dispersing oral tablets. The addition ratios stated below are process-starting ranges derived from common industrial batch records for low-dose oral solids and aqueous injectables; they are not release specifications and must be verified against the API particle size distribution, crystalline form, and dose. Published data for this specific API at every combination of buffer, pH, and fill volume may be limited; in such cases, the processing window is described by the governing standard or equipment boundary rather than by extrapolated values.

    What Happens to Blend Uniformity When the API Is Directly Compressed Below 5% w/w?

    In direct compression of low-dose oral tablets, the critical quality parameter is content uniformity because the active pharmaceutical ingredient is blended at 0.5–5.0% w/w of the total core mass, corresponding to a unit dose of 1.0–10.0 mg in a 100–200 mg tablet. The API is first co-milled with 40–60% w/w microcrystalline cellulose through a 0.5 mm conical mill screen at 1,500–2,500 rpm to reduce agglomerates and create a particle size ratio below the segregation threshold. The co-mill is discharged into a 300 L bin blender and mixed at 10–15 rpm for 15–20 minutes; magnesium stearate is then added at 0.25–0.75% w/w and blended for 3–5 minutes. Production-scale batch records show that extending magnesium stearate lubrication beyond 5 minutes can reduce tablet hardness by 10–20% and increase disintegration time. Compression is performed on a rotary tablet press fitted with 10.0 mm B-tooling at 8–18 kN compression force, producing tablets with hardness 60–120 N and friability below 1.0% w/w. Content uniformity is assessed by Ph. Eur. 2.9.40 and USP <905>; dissolution is controlled by USP <711> Apparatus 2 at 50 rpm in 900 mL of pH 6.8 phosphate buffer. The terminal finished product is an immediate-release tablet, with microbial quality aligned to Ph. Eur. 5.1.4, residual solvents under ICH Q3C, and elemental impurities under ICH Q3D. If ambient relative humidity exceeds 60%, the API is pre-dried in a vacuum oven at 40°C for 6 h before dispensing; reducing sugars are excluded from the formulation because Maillard degradation of primary-amine APIs can occur during direct compression.

    Hard capsule filling of the API is performed at a lower addition ratio than direct compression because the powder is dispersed in a precompacted carrier blend to offset static charge and poor flow. The formulation is prepared by dry granulating a 1:6 API-to-mannitol premix through a roller compactor with 1.0 mm screen and 15–20 kN/cm roll force, then blending the milled granules with crospovidone at 2.0–5.0% w/w, colloidal silicon dioxide at 0.2–0.5% w/w, and sodium stearyl fumarate at 0.5–1.0% w/w; the final API content is 2.5–12.5% w/w of the filled capsule mass. Filling is carried out on an intermittent-motion capsule filler equipped with dosator pins, target fill weight 150–350 mg, size 3 or 4 HPMC capsules, at 25±2°C and ≤30% relative humidity. In-process verification follows Ph. Eur. 2.9.40 for content uniformity, USP <711> for dissolution, and USP <922> for water activity; the water activity is held below 0.35 to prevent capsule shell embrittlement and reduce moisture-driven API degradation. The terminal finished product type is a hard capsule; capsule shell moisture is controlled through water activity rather than a fixed moisture specification, and microbiological quality follows Ph. Eur. 5.1.4. Capsule filling lines operating above 30% RH require dehumidified service air and a desiccant canister in the finished pack because HPMC shells may plasticize or become tacky at water activity above 0.45.

    When Fluid-Bed Granulation Replaces Direct Compression for Moisture-Sensitive Oral Granules

    In moisture-sensitive oral granule production, the API is incorporated at 0.5–8.0% w/w of the dry granule mass by dissolving or suspending it in an aqueous hydroxypropyl cellulose binder solution at 2.0–4.0% w/w; the binder solution is sprayed onto a fluidized bed of mannitol and pregelatinized starch in a top-spray fluid-bed granulator with 1.5–3.0 bar atomizing air, inlet air temperature 55–65°C, product temperature 30–38°C, and spray rate 8–20 g/min. The granulation endpoint is set by loss-on-drying at 1.5–2.5% w/w; the dried granule is classified through a 1.0 mm sieve before blending with crospovidone at 2.0–5.0% w/w and sodium stearyl fumarate at 0.5–1.0% w/w. Over-wetting must be avoided because residual moisture above 2.5% w/w can bind free water at the API particle surface and accelerate hydrolysis during sachet storage. Compliance anchors are Ph. Eur. 2.9.40 for single-dose sachet uniformity, Ph. Eur. 2.9.3 for dissolution of powder for oral solution, ICH Q3C for residual solvents if a hydroalcoholic binder is used, and Ph. Eur. 5.1.4 for microbial quality. The terminal finished product type is a granule-filled sachet or oral powder for reconstitution; the granule is not compressed into a tablet, and particle size is typically controlled at 0.15–0.85 mm to ensure rapid dispersion after reconstitution.

    3 ml Cartridge Aseptic Filling Line Parameters and Silicone Oil Layer Benchmarks

    Aseptic filling of the API into 3 ml type I borosilicate glass cartridges for disposable pen injectors is performed within an isolator using a peristaltic or ceramic piston pump; the bulk solution is passed through a 0.22 µm sterilizing-grade membrane filter immediately before filling. The formulation addition ratio is expressed as API concentration in the final solution, commonly 0.25–10.0 mg/mL, with tonicity adjusted to 250–350 mOsm/kg using glycerol or sodium chloride, pH maintained between 3.5–7.4 according to the stability profile, and a multi-dose cartridge preserved with phenol at 0.25–0.50% w/w or m-cresol at 0.15–0.30% w/w where the product is designed for multiple injections. Fill volume is set at 1.5–3.0 mL, with in-process checks of fill weight, stopper insertion depth, and plunger glide force; silicone oil levels in the cartridge barrel are typically held below 0.2 mg per cartridge unless the pen injector manufacturer specifies otherwise. The terminal finished product type is a filled 3 ml cartridge integrated into a disposable pen injector or supplied as a cartridge component for final device assembly. Compliance standards include ISO 11608-1 for needle-based injection systems, ISO 13926-1 for glass cylinders for pen injectors, Ph. Eur. 3.2.1 for glass containers, USP <1> for injections, USP <790> for visible particulates, and EU GMP Annex 1 for aseptic processing. Terminal steam sterilization is not applied to the filled cartridge because the API is usually thermolabile; therefore, the entire aseptic train and isolator transfer must maintain grade A conditions at the point of fill.

    Control pointStandardProcess limit
    Cartridge glass typePh. Eur. 3.2.1Type I borosilicate glass, 3 ml nominal fill volume
    Sterilizing filtrationEU GMP Annex 10.22 µm membrane, pre-use integrity test
    Visible particulatesUSP <790>Practically free from visible particulates
    Pen injector systemISO 11608-1Dose accuracy and injection depth verified per device design

    Lyophilized injection cakes for APIs that hydrolyze in aqueous solution at long-term storage temperatures are prepared by aseptic filling of a bulk solution containing the API at 1.0–10.0 mg/mL, mannitol or trehalose at 2.0–5.0% w/w, and a phosphate or citrate buffer system at 5–20 mM into 6R type I glass vials. The solution is filtered through 0.22 µm PES membrane, filled at 2.0–5.0 mL per vial, and partially stoppered before loading into the freeze dryer. The freezing stage is ramped to -45°C at 0.5–1.0°C/min; primary drying is executed at -20°C and 50–100 µbar for 24–48 h; secondary drying is executed at 20–30°C for 6–12 h until residual moisture is ≤2.0% w/w. Compliance anchors are USP <1> for injections, USP <921> for water determination, USP <71> for sterility, and ICH Q1A for stability evaluation. The terminal finished product type is a lyophilized injection powder for reconstitution with water for injection before subcutaneous or intramuscular administration. If the API has primary amine groups, trehalose is preferred over mannitol during process development because reducing sugars must be excluded to prevent cake collapse and browning; published data for this specific API at every buffer concentration may be limited, so the final lyophilization cycle is confirmed by freeze-drying microscopy rather than fixed thermal parameters.

    Direct Compression of Fast-Dispersing Tablets Uses a Carrier Pre-Mix With a Water Activity Below 0.30

    For fast-dispersing oral tablets, the API is loaded at 1.0–7.5% w/w into a carrier platform of mannitol, crospovidone, and microcrystalline cellulose; the pre-mix water activity is held below 0.30 to maintain the amorphous state of the API and prevent porosity collapse during compression. Blending is performed in a low-shear drum blender at 8–12 rpm for 10–15 minutes; magnesium stearate is added at 0.5% w/w for 2 minutes. Tablets are compressed on a rotary press with 12.0 mm multi-tip tooling at 6–12 kN, producing hardness 30–60 N and disintegration below 60 seconds per Ph. Eur. 2.9.1. The terminal finished product type is an orally dispersible tablet intended for administration without water. Content uniformity is assessed by Ph. Eur. 2.9.40 and USP <905>, friability by Ph. Eur. 2.9.7, and elemental impurities by ICH Q3D. If tablet hardness exceeds 60 N, disintegration time may exceed the 60-second target because the compressed matrix loses capillary wicking; if hardness falls below 30 N, friability increases beyond 1.0% w/w and the tablet edge may fracture during handling.

    Free Quote

    Competitive Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Disposable Pen Injector with 3 ml Cartridge: Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    Model DPI-3C-PG-API is a single-use, variable-dose pen injector supplied with a 3 ml cartridge containing pharmaceutical-grade active pharmaceutical ingredient. The listing title “Disposable pen injector with 3 ml cartridge Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable” describes a dual application scope: the pen injector and cartridge are used for subcutaneous or intramuscular injection of the API, while the same pharmaceutical-grade API is acceptable as a raw material for tablet, capsule, granule, oral liquid, and injectable finished-dose manufacture when transferred to appropriate processing equipment. The cartridge itself is not used as a tablet or capsule processing vessel. For parenteral use, the device requires a pen needle hub conforming to ISO 11608-2:2022. Dose setting is adjustable in 0.01 ml increments across the range 0.01 ml to 3.00 ml. The single-use mechanism prevents cartridge exchange and reuse, which reduces cross-contamination risk in multi-dose clinical environments but increases primary packaging consumption compared with reusable cartridge pens.

    Cartridge Fluid Path and Device Materials

    The fluid path consists of a Type I borosilicate glass cartridge specified to USP <660>, a bromobutyl elastomer plunger stopper tested to USP <381>, and an aluminium crimp cap with polyisoprene disc. The inner glass surface is siliconised at a validated level; for a 3 ml cartridge, typical silicone levels are 0.2–0.4 mg/dm², but the exact released value is product-specific. Break-loose and glide force testing uses a universal test frame equipped with a 50 N load cell and a crosshead speed of 60 mm/min. For a 1.0 ml dose through a 32G pen needle, acceptance limits are generally set below 20 N break-loose force and below 10 N glide force at 25 °C. These limits are derived from published pen-injector friction studies; product-specific values are provided in the device technical file.

    Primary specifications and referenced methods
    Parameter Specification
    Product model DPI-3C-PG-API
    Nominal cartridge fill volume 3.0 ml
    Dose adjustment increment 0.01 ml
    Dose range 0.01 ml to 3.00 ml
    Needle hub interface ISO 11608-2:2022
    Cartridge glass USP <660> Type I borosilicate
    Plunger stopper USP <381> bromobutyl elastomer
    Dose accuracy reference method ISO 11608-1:2022, gravimetric delivery
    Storage temperature, small-molecule aqueous API 15–25 °C
    Storage temperature, biological API 2–8 °C
    Maximum recommended viscosity, 32G needle 20 cP
    Maximum recommended viscosity, 30G needle 30 cP
    Filling environment ISO 14644-1 class 5

    Each pen injector is sealed in a polyethylene terephthalate tray with a coated Tyvek lid. Empty device components are sterilized by gamma irradiation; the prefilled cartridge is filled under aseptic conditions within an ISO 14644-1 class 5 barrier isolator or restricted access barrier system. If the API is heat-labile, terminal sterilization is not applied. The finished package is labeled with API name, strength, lot number, storage temperature, and the statement that the device is for single use only.

    Cartridge filling is executed on a line equipped with ceramic rotary piston pumps having a 3.0 ml nominal fill volume. In-process gravimetric checks are performed at 30-minute intervals. The filling line qualification follows ISO 13485:2016 and current good manufacturing practice for sterile medicinal products. Visible particulates are controlled under USP <790>; sub-visible particulate testing is performed by light obscuration per USP <787>. For formulations with viscosity above 15 cP, filling speed is reduced and the nozzle inner diameter is increased from 1.0 mm to 1.5 mm to limit cavitation and foam formation. These adjustments are line-specific and are not stated as universal values.

    Mechanical dose accuracy and what limits it

    Dose accuracy in a 3 ml disposable pen is governed by cartridge bore diameter, stopper compression set, and dose nut backlash. The cartridge bore tolerance for pen injector cartridges is specified at ±0.1 mm because a bore shift of 0.05 mm alters the cross-sectional area and the delivered volume per linear lead screw step. The dose nut and lead screw are molded from polyacetal or polybutylene terephthalate; dimensional variation in these parts contributes to cumulative dose error. Gravimetric delivery across the stated dose range is evaluated according to ISO 11608-1:2022 using a calibrated balance with 0.01 mg readability. Acceptance limits for comparable variable-dose pens are commonly ±1.0% or ±0.01 ml, whichever is greater; released product-specific limits are recorded in the device technical file.

    What limits injection force for a 3 ml disposable pen?

    Injection force in a 3 ml disposable pen is limited by stopper friction, cartridge inner diameter, needle gauge, and formulation viscosity. Stopper break-loose force typically exceeds glide force by a factor of 1.5 to 3.0 for bromobutyl elastomers against siliconised Type I glass. During delivery, a 32G needle presents a higher pressure drop than a 30G needle, and formulations above 20 cP may exceed a patient-acceptable force ceiling. A commonly used maximum injection force for manual pen injectors is 15 N for a 1.0 ml dose; spring-driven or motor-driven platforms may be required when the dose cannot be delivered within 15 seconds. The test method in ISO 11608-1:2022 does not set a universal force limit, so the upper limit is derived from human factors validation for the intended patient population.

    When the same API grade is processed into tablets, capsules, or granules

    The pen injector hardware is not used in oral solid-dose manufacturing. The API grade identified in the product listing is transferred from the cartridge or an equivalent container into direct compression, wet granulation, roller compaction, or capsule filling equipment. For direct compression, the API is blended in a bin blender at 15–25 rpm for 10–20 minutes; if the bulk density is below 0.35 g/ml, pre-densification by slugging or roller compaction is typically required to improve flow and reduce segregation. Tablet compression on a rotary press applies compaction forces of 5–25 kN depending on API brittleness and target hardness. Capsule filling on a dosator or tamping-pin machine requires the blend to pass USP <1174> flowability evaluation; fill weight uniformity is assessed under USP <905>. Wet granulation may be performed in a 25 L high-shear granulator with purified water or a binder solution added at 2–5% w/w of dry powder mass. The granules are dried to a loss on drying of 1–3% and then lubricated with magnesium stearate at 0.5% w/w for 3–5 minutes. These are processing ranges for the API, not properties of the cartridge component.

    Cold-chain handling controls apply to biological APIs in the 3 ml cartridge. The device should not be frozen. Freeze–thaw cycling above 2 cycles may alter stopper sealing force and redistribute the silicone layer, leading to higher glide force or subvisible particle formation. Cartridges removed from 2–8 °C storage should equilibrate to 15–25 °C for at least 30 minutes before dose setting. For suspension formulations, a resuspension step of 10 manual inversion cycles is validated by particle size distribution and content uniformity testing. Published data for this specific configuration is limited; therefore, the resuspension procedure is established per formulation development and is not transferred between products without verification.

    Differences from reusable pens and prefilled syringe platforms

    The DPI-3C-PG-API differs from a reusable cartridge pen in four operational areas: absence of a reset function, absence of a replaceable cartridge, higher single-use packaging burden, and a simpler user sequence with fewer assembly steps. Compared with a 3 ml prefilled syringe, the pen injector provides dose subdivision in 0.01 ml increments and uses a separate user-attached needle, but it is not suitable for intravenous or intrathecal administration. Compared with a 1.0 ml or 2.0 ml pen injector, the 3 ml cartridge reduces the number of cartridge changes in a multi-dose regimen but increases device mass and grip span. Patients with reduced manual dexterity should be evaluated against maximum injection force and needle attachment torque; published data for this exact configuration is limited.

    Comparative characteristics across device categories
    Feature DPI-3C-PG-API Reusable cartridge pen Prefilled syringe Autoinjector
    Cartridge or container volume 3 ml 3 ml 1–5 ml 1–2.5 ml
    Dose setting 0.01 ml increments Variable Fixed Fixed or automatic
    Reuse None Cartridge replacement None None
    Needle attachment ISO 11608-2:2022 user-attached User-attached Integral or Luer Integral hidden
    Primary standards ISO 11608-1:2022, USP <660>, USP <381> ISO 11608-1:2022 ISO 11040-4 ISO 11608-1:2022
    Typical patient force ceiling 15 N for 1.0 ml, 32G 10–15 N 5–15 N Automatic
    Cross-contamination risk Low Medium Low Low
    Packaging burden High Low Medium High

    The disposable pen is not indicated for intravenous, intrathecal, intra-arterial, or intra-articular administration. Formulations with pH below 3.0 or above 10.0, or formulations containing organic solvents, require a primary container compatibility study before use because glass delamination or stopper swelling may occur. High-alert drugs and cytotoxic agents should be handled under a closed-system drug transfer device according to NIOSH Alert 2004-165 and USP <800>; the pen injector does not substitute for those protective measures. Cartridges with visible cracks, turbidity, or plunger movement before use are rejected without dose compensation.

    Top