Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@sinochem-nanjing.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 913702
    Product Name Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    Material Cyclo Olefin Polymer (COP)
    Material Grade Pharma Grade
    Polymer Type Amorphous thermoplastic cyclo olefin polymer
    Primary Container Pre-filled syringe
    Compatible Dosage Forms Tablet, capsule, granule, injection
    Route Of Administration Oral and injectable
    Transparency High optical clarity and transparency
    Barrier Properties High moisture barrier and high oxygen barrier
    Chemical Resistance Good resistance to aqueous solutions, acids, bases, alcohols, and many polar solvents
    Extractables And Leachables Low extractables and leachables profile
    Sterilization Compatibility Compatible with autoclave, ethylene oxide, gamma irradiation, and electron beam sterilization
    Regulatory Compliance Complies with USP Class VI, ISO 10993, EP, and FDA requirements for pharmaceutical contact
    Temperature Stability Suitable for low-temperature storage and terminal sterilization; typical glass transition temperature approximately 130-140°C
    Water Absorption Very low water absorption, generally less than 0.01%
    Density Approximately 1.01 g/cm³
    Refractive Index Approximately 1.53
    Surface Energy Low surface energy and hydrophobic surface
    Break Resistance High break resistance compared with glass
    Particulate Generation Low particulate generation
    Shelf Life Typically 2 to 5 years depending on drug formulation and storage conditions
    Drug Compatibility Compatible with many small-molecule and biologic drugs; specific compatibility testing required
    Capacity Range 0.5 mL to 50 mL
    Needle Options Staked needle, luer lock, luer slip
    Closure System Rubber stopper, plunger, tip cap

    As an accredited Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in 10 mL cyclo olefin polymer (COP) pre-filled syringes, 100 syringes per carton, pharma-grade API for oral and injectable use.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Pharma-grade Cyclo Olefin Polymer (COP) pre-filled syringes for tablets, capsules, granules, oral and injectable APIs, securely packed.
    Shipping COP pre-filled syringes are shipped in validated, tamper-evident, temperature-controlled packaging with shock protection and data loggers. IATA/DOT-compliant labels, certificates of analysis, safety data sheets, and customs documents accompany each pharma-grade shipment for oral and injectable use.
    Storage Store in original, unopened packaging, upright, in a cool, dry, well-ventilated area at controlled room temperature (15–25°C/59–77°F). Protect from direct sunlight, moisture, dust, and contamination. Do not freeze or expose to excessive heat. Keep away from incompatible materials and ignition sources. Avoid excessive vibration or pressure. Follow manufacturer instructions, shelf-life limits, cGMP, and local regulations.
    Shelf Life Typically 24–36 months when stored sealed, protected from light, heat, and moisture, per manufacturer stability data.
    Application of Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    In monoclonal antibody fill-finish operations, the COP pre-filled syringe barrel is converted from medical-grade cyclic olefin resin at a controlled moisture content below 1,000 ppm before molding because residual moisture produces splay and void defects in the barrel wall. Typical high-concentration formulations contain 20 mg/mL to 150 mg/mL protein in histidine, acetate, or phosphate buffers at pH 5.0–7.5, and the barrel must not contribute metal cations, tungsten oxide, or silicone oil droplets that promote interface-induced aggregation. The barrel is injection-molded on multicavity hot-runner molds with polished optical surfaces, and gate vestige height is maintained below 0.1 mm to avoid stopper seal damage during insertion; mold temperature for pharmaceutical COP grades is generally held between 50 °C and 90 °C to control birefringence and dimensional consistency across 16–64 cavity tools. After molding, the internal surface is either siliconized with a target layer of low-viscosity silicone oil or coated with a non-silicone lubricious layer, because the break-loose and glide forces measured on a texture analyzer at 50 mm/min depend on the surface treatment rather than on the COP substrate alone. The staked needle is attached by UV-cured adhesive or insert molding, eliminating tungsten-pin residues that are characteristic of glass syringe conversion. Extractables are evaluated according to USP <661>, USP <1663>, and Ph. Eur. 3.1.3, with the analytical evaluation threshold calculated from the maximum daily injected volume. Final barrel dimensions and closure performance are verified against ISO 11040-6:2019 using calibrated vision systems and CCI test methods from USP <1207>. Batch-to-batch mold variation is controlled by weighing every barrel in high-speed checkweighers and by pass-fail polarized light inspection for residual stress, because stress above a validated threshold appears later as crack propagation during stopper insertion or as increased extractables after solvent exposure.

    What Limits Cold-Chain Toughness and Extractables Leaching in mRNA-LNP Vaccine Syringe Systems?

    The dominant cold-chain failure mode in COP barrels is not low-temperature brittleness in all grades, because fully amorphous cyclic olefin polymers retain useful impact resistance at −70 °C when the comonomer ratio and molecular weight are selected for ductile rather than high-Tg packaging. However, commercial COP grades exhibit a coefficient of linear thermal expansion on the order of 6–8 × 10⁻⁵ K⁻¹, which is higher than borosilicate glass, so repeated thermal cycling between −70 °C and 25 °C can shift the plunger stopper axial position and change closure seal compression. Frozen mRNA-LNP formulations typically contain ionizable cationic lipids, cholesterol, PEGylated lipid, and mRNA in TRIS or sucrose buffers at pH 7.0–7.5; extractables arising from the COP barrel under frozen storage are evaluated by USP <1663> and leachables by USP <1664>, but published data for this specific configuration at commercial scale are limited. Material qualification therefore includes notched impact testing at −70 °C per ISO 179-1/1eA and container closure integrity testing after thermal cycling per USP <1207>. Gamma irradiation at 25–40 kGy may induce oxidative yellowing in some COP grades, so component sterilization by ethylene oxide or nitrogen dioxide is preferred when the manufacturer’s validated irradiation dose cannot be applied. The molded barrel must also pass visual inspection under polarized light for birefringence concentration near the gate, because residual stress can become a crack initiation site after frozen storage. In addition, the plunger stopper is often a bromobutyl elastomer with fluoropolymer laminate; its compression set at −70 °C must be evaluated because the stopper can lose radial sealing force after prolonged frozen storage, independent of COP barrel performance.

    Test stageStandardMeasured parameter
    Barrel dimensional qualificationISO 11040-6:2019Inner diameter, flange, closure compatibility, break-loose/glide force
    Resin and molded part purityUSP <661>Physicochemical extractables, residue on ignition, heavy metals
    Polyolefin-specific migrationPh. Eur. 3.1.3Migration limits, acidity/alkalinity, UV absorption
    Extractables profilingUSP <1663>Volatile, semivolatile, nonvolatile compounds under exaggerated conditions
    Leachables risk assessmentUSP <1664>Compound-specific analytical evaluation threshold
    Subvisible particles in protein injectionsUSP <787>≥10 µm and ≥25 µm particle counts
    General particulate matterUSP <788>≥10 µm and ≥25 µm particle counts
    Container closure integrityUSP <1207>Vacuum decay, laser headspace, dye ingress
    Needle-based injection systemISO 11608-1:2022Dose accuracy, activation force, system safety

    Intravitreal anti-VEGF delivery imposes a fill volume of 0.03–0.05 mL, which compresses the acceptable dosing error to ±10% and demands barrel dimensional uniformity across an entire molding batch. In ophthalmic PFS formats, the injection depth is small and the needle gauge ranges from 30 G to 33 G, so silicone oil migration into the vitreous cavity can appear as symptomatic floaters and is treated as a critical quality attribute. The COP barrel is selected because it can be processed with reduced silicone oil load or paired with a coated elastomer plunger, while the barrel wall itself contributes no tungsten and no glass flakes. Subvisible particle monitoring must comply with USP <787> for therapeutic protein ophthalmic injections and USP <788> for compendial particulate matter, with light obscuration and membrane microscopy used in parallel because silicone oil droplets may interfere with light obscuration counts. In filling, piston pump accuracy at these small volumes is verified gravimetrically on statistical sampling frequencies, and the COP barrel’s internal diameter tolerance from ISO 11040-6:2019 is correlated with delivered dose volume before scale-up. Terminal sterilization is generally not applied to the filled anti-VEGF drug product; instead, the sterile barrel is filled under ISO 5 aseptic conditions as defined by ISO 14644-1:2015, and the final closed syringe undergoes high-voltage leak detection followed by visual inspection. The residual volume of an intravitreal PFS is specified by the dosing volume plus an overfill, but overfill in a 0.05 mL dose is a disproportionate fraction of the nominal fill; therefore the barrel diameter tolerance and plunger seating depth become process-critical rather than merely dimensional notes.

    When Lyophilized Cakes Move into Dual-Chamber COP Barrels

    Dual-chamber lyophilization in a polymer barrel introduces heat transfer asymmetries that are not present in glass. COP has lower thermal conductivity than borosilicate glass, with typical values near 0.2 W/mK for COP and 1.0 W/mK for borosilicate glass, so primary drying shelf temperatures and chamber pressures must be re-established when a lyophilized cake is transferred from a glass vial or glass syringe to a COP dual-chamber format. Water vapor transmission through COP is higher than through glass; when tested per ISO 15106-2, the COP barrel shows a measurable transmission rate while glass is effectively impermeable, and hygroscopic drug cakes are therefore protected by an aluminum barrier overwrap or a desiccant pouch in secondary packaging after stopper closure. The bypass channel required for dual-chamber reconstitution is molded directly into the COP barrel wall, and its geometry must remain dimensionally stable after the lyophilization cycle, which may include freezing to −45 °C and primary drying at 0 °C to 10 °C for several hours. Residual moisture in the cake is verified by Karl Fischer titration, and the polymer barrel is checked for irreversible deformation because COP can relax molded-in stress above its glass transition temperature (70 °C–180 °C depending on grade) if extreme sterilization or drying conditions are used. The partial seating of the lyophilization stopper depends on the inner diameter tolerance in ISO 11040-6:2019, and the chamber design must allow vapor escape before full stopper seating. Container closure integrity after reconstitution is tested by vacuum decay per USP <1207>, and dye ingress is used as a secondary check for the bypass channel.

    High-Viscosity Biologic Cartridge Dimensional Tolerance and Hoop Stress Behavior

    At the cartridge-to-auto-injector interface, COP must be assessed for hoop stress under spring-driven injection rather than for static storage alone. High-concentration subcutaneous biologics with dynamic viscosity of 20–30 mPa·s at 25 °C can generate syringe forces sufficient to expand a thin-wall polymer barrel, altering dose accuracy and stopper seal contact. The barrel is therefore molded to the dimensional limits in ISO 11040-6:2019 and tested for burst resistance and axial load at the flange using universal tensile equipment with calibrated fixtures. Auto-injector manufacturer specifications, including spring preload and needle gauge, drive the internal pressure calculation; a 27 G or 29 G thin-wall needle creates a higher back pressure than a 1 mL glass cartridge, but the COP barrel compensates only if wall thickness and molecular orientation are controlled. Birefringence mapping across the barrel length is required because injection-molded COP can retain molecular orientation that influences hoop strength and solvent resistance. The final subassembly is evaluated according to ISO 11608-1:2022 for needle-based injection systems, and the delivered dose volume is verified by gravimetric injection into a collection vessel. Failed units on manufacturing lines typically originate from flange cracking during spring release or from stopper binding after siliconization variability; these failure modes are controlled through incoming resin melt-flow stability measured by ISO 1133-1:2022 and molded internal surface roughness measurement.

    Organic Co-solvent and High-pH Injectable Formulations Stress COP Permeation and Glass-Delamination Alternatives

    Replacement of borosilicate glass in high-pH parenteral formulations is driven by the known failure mechanism of glass delamination, not by unresolved COP compatibility claims. In formulations containing benzyl alcohol, ethanol, propylene glycol, PEG 300, or 5–20% w/w organic co-solvent, COP can undergo localized swelling or molecular relaxation, and the inner barrel surface must be evaluated for weight change, surface tack, and extractables after storage at 40 °C and 75% relative humidity for 6 months. Unlike glass, the amorphous polyolefin backbone is resistant to alkaline hydrolysis at pH 9–11, but certain lipophilic excipients may partition into the free volume of the polymer; the analytical evaluation threshold from USP <1664> is compound-specific and cannot be extrapolated from one solvent system to another. The barrel is conditioned in the intended formulation at the proposed storage orientation to capture the effect of solvent contact on the liquid meniscus and stopper seal. Dimensional stability is measured after exposure because organic co-solvent uptake can produce a small reversible expansion that influences break-loose and glide force. The finished PFS is subjected to extractables testing per USP <661> and Ph. Eur. 3.1.3, and the drug product is tested for partition coefficient shift of critical impurities. For high-pH small-molecule injectables, COP provides an operational boundary beyond the pH range at which borosilicate glass flake formation is observed, but the barrel is not treated as universally solvent-resistant. In addition, elastomer compatibility must be separated from COP compatibility by using unlined and lined stopper materials in the screening matrix, because closure extractables can otherwise be misattributed to the barrel.

    Cytotoxic and highly potent small-molecule injectables present a different extractables profile because the drug product itself may act as an aggressive extracting solvent after long storage. In oncology PFS applications, the COP barrel is qualified with the actual drug product at final concentration, including any polysorbate or Cremophor-type surfactant, rather than with a model solvent only. Extractable and leachable studies follow USP <1663> and USP <1664>, and the leachable risk assessment is linked to the maximum daily dose and duration of treatment under FDA 21 CFR 211.94(a). The barrel’s low metal extractable profile reduces the risk of oxidation of labile APIs, but hydrophobic small molecules may adsorb to the polymer surface; adsorption is measured by spiked recovery studies at 1 µg/mL to 100 µg/mL depending on the formulation concentration. The filled syringes are inspected for subvisible particles using USP <788>, and final oil content in the product is monitored when the COP barrel is siliconized. Batch release includes a molded barrel residual stress check and a stopper insertion force measurement because variability at the glass-to-polymer switch can appear as cracked barrels or raised silicone oil droplets. The pre-filled syringe grade of COP is not qualified as an excipient for tablet, capsule, granule, or oral powder processing; its pharmacopoeial assessment is confined to injectable primary packaging components.

    Free Quote

    Competitive Cyclo Olefin polymer (COP) Pre-filled Syringe Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Cyclo olefin polymer (COP) pre-filled syringe barrels are supplied as primary container-closure systems for active pharmaceutical ingredients formulated as injectable solutions, injectable suspensions, oral solutions, and oral suspensions reconstituted from tablet, capsule, and granule presentations. The resin is a hydrogenated ring-opened polynorbornene-type COP rather than an ethylene-norbornene copolymer, and is processed into 1 mL and 2.25 mL barrel configurations specified by ISO 11040-6. The product is a container-closure and delivery device for APIs rather than an active pharmaceutical ingredient. Material selection is driven by the absence of a glass delamination mechanism, low aqueous extractables, dimensional uniformity in injection stretch-blow molding, and compatibility with silicone oil-free plunger systems. Acceptance testing includes dimensional checks per ISO 11040-6, physicochemical testing per USP <661.1> and USP <661.2>, and biological evaluation per ISO 10993-1:2018. Model-specific dimensional drawings and lot-specific release data govern final use; ISO 11040-6 defines dimensional interfaces rather than proprietary part numbers.

    What separates COP from COC and Type I borosilicate glass in a pre-filled syringe?

    In a COP pre-filled syringe, the barrel resin is a hydrogenated ring-opened polynorbornene-type homopolymer. This architecture differs from ethylene-norbornene cyclic olefin copolymer produced by insertion polymerisation. The homopolymer structure of COP provides a higher continuous-use temperature than many COC grades, but the two materials share comparably low water absorption and high transparency. Type I borosilicate glass has a rigid silicate network that provides burst strength but creates a delamination failure mode when the inner surface is exposed to high-pH formulations or terminal sterilisation media. The following table summarises the property differences relevant to pre-filled syringe operation.

    Comparative properties of COP pre-filled syringe grade, COC pre-filled syringe grade, and Type I borosilicate glass
    PropertyTest methodCOPCOCType I glass
    DensityISO 1183-1:20191.01 g/cm³1.02 g/cm³2.23 g/cm³
    Water absorption, 24 hISO 62:2008<0.01 %<0.01 %not applicable
    Light transmittance, 3 mmISO 13468-1:201992 %92 %90–91 %
    Glass transition temperatureISO 11357-2:2020136–165 °C78–180 °Cnot applicable
    Coefficient of linear thermal expansion, 23–80 °CISO 11359-2:202160–70 × 10⁻⁶ K⁻¹60–70 × 10⁻⁶ K⁻¹3.3–5.1 × 10⁻⁶ K⁻¹

    The practical consequence of these property differences is that COP cannot be depyrogenated in a dry-heat tunnel, and it introduces a higher gas-transmission pathway than glass; secondary packaging and oxygen scavengers are required for oxygen-sensitive products. Published gas-transmission values for COP barrels are configuration-dependent and must be obtained from the resin supplier rather than treated as universal constants.

    Barrel production on electric multi-cavity injection stretch-blow molding equipment requires pre-drying at 80 °C to 100 °C for 3 h to 4 h. Residual moisture above 0.02 % vaporises during plastication and generates splay, silver streaks, and localized surface roughness on the shoulder and cone regions. Screw plastication with a compression ratio of 2.0:1 to 2.5:1 and a metering-zone temperature of 240 °C to 280 °C is typical for high-purity grades; melt residence times above 10 min at temperatures exceeding 300 °C increase oligomer and aldehyde formation in the finished barrel. Hopper-air dew point below −40 °C is recommended to prevent moisture regain during extended production runs.

    In-line laser profilometry and plug-gauged vision inspection are used to hold body outer diameter and inner diameter within the tolerances defined by ISO 11040-6. Dimensional control is more demanding than for glass because the linear coefficient of thermal expansion of COP is 60–70 × 10⁻⁶ K⁻¹, roughly 12–20 times that of Type I borosilicate glass. Mold temperature, blow pressure, and stretch-pin speed are locked after qualification; on multi-cavity hot-runner tools, unbalanced nozzle-tip heating produces cavity-to-cavity flange thickness variation of ±0.05 mm. Resin lot-to-lot melt flow-rate variation of ±0.2 g/10 min is sufficient to shift preform wall thickness unless the injection unit uses closed-loop cushion control and in-line weight correction.

    If terminal steam sterilisation is required, the selected COP grade must not exceed its heat deflection threshold

    High-Tg COP grades with a heat deflection temperature under 0.45 MPa load in the range 125 °C to 140 °C may withstand validated 121 °C steam cycles for 15 min when mandrel-supported in a form-fitting tray. Grades with lower heat deflection temperatures deform at the flange and cone under the same conditions. Because COP has a glass transition temperature of 136–165 °C, dry-heat depyrogenation at 250 °C is outside the operational envelope; terminal sterilisation must use gamma irradiation at 25–40 kGy, electron beam irradiation with dose validation, or ethylene oxide where process residuals are controlled according to ISO 10993-7:2008.

    Sterilisation by gamma irradiation at 25–40 kGy is widely used for ready-to-fill COP barrels. Post-irradiation extractables and colour are assessed per USP <661.1> and USP <661.2>; oxidative yellowing can appear at higher doses, especially in the presence of oxygen. Vacuum-sealed barrier pouch storage with an oxygen scavenger minimises post-irradiation oxidative changes. Autoclaving is an operational boundary and is not used unless the specific grade and barrel geometry have dimensional stability data.

    Cold-chain storage at −80 °C does not introduce breakage failure in COP barrels, but plunger seal integrity is governed by elastomer compression set and the difference in thermal contraction between COP and the plunger rubber. The COP barrel contracts with a coefficient of 60–70 × 10⁻⁶ K⁻¹; elastomer closures typically contract more. Container closure integrity loss can occur when plunger ribs lose radial contact during ice-phase thermal excursions. Package qualification therefore includes container closure integrity testing at −80 °C, −20 °C, 2–8 °C, and 25 °C/60 % RH using vacuum decay or helium leak methods per USP <1207>.

    Leachables, Extractables and Silicone Oil-Free Closing Systems

    Extraction screening for injectable-use COP barrels is conducted under accelerated conditions derived from ICH Q1A. Model solvents include water for injection, 0.9 % sodium chloride, pH 3 and pH 9 buffer, and 10 % ethanol/water at temperatures from 40 °C to 70 °C. Headspace gas chromatography mass spectrometry, liquid chromatography mass spectrometry, and inductively coupled plasma mass spectrometry are used to identify organic and elemental extractables. Sample preparation follows ISO 10993-12:2021, and analytical evaluation thresholds are derived from the parenteral safety concern threshold of 1.5 µg/day for individual organic leachables. Supplier data for high-purity COP resin often report total organic extractables in aqueous model extracts below 0.1 µg/mL, but this is not a compendial release limit and batch-specific data are required for each drug application.

    Silicone oil-free systems are used when protein aggregation and subvisible particles associated with silicone oil are critical quality attributes. The COP barrel surface can be paired with a fluoropolymer-coated bromobutyl plunger or a silicone-free elastomer formulation. Break-loose and extrusion force are measured under constant-rate conditions in accordance with the functional test procedures of ISO 11040-6; no universal force limit applies because test speed, fill volume, and formulation viscosity shift the results. Silicone oil-free systems typically increase initial break-loose force relative to siliconized glass, and this must be included in human factors and usability validation.

    Chemical incompatibility exists with chlorinated solvents, tetrahydrofuran, strong alkalis at high temperature, and prolonged exposure to aromatic hydrocarbons. Inspection and cleaning should be limited to purified water, isopropanol/water mixtures, or qualified non-polar washes of short duration. Formulations containing >20 % ethanol require extractables and stress-cracking evaluation because of plasticization at thin-wall sections.

    Uncoated COP transmits 92 % visible light and allows UV-A transmission. Amber-tinted COP or secondary packaging with UV barrier is required when the API has a photodegradation pathway. Colourants are introduced only as physiologically accepted masterbatches with a qualified extractables profile; many injectable applications retain an uncoloured, transparent barrel to permit automated visual inspection.

    Subvisible particle control is monitored by light obscuration per USP <787> for protein formulations and USP <788> for conventional injectables. Assembly and packaging are performed in cleanrooms not lower than ISO 14644-1:2015 Class 7 for component handling and Class 5 for critical fill-zone interfaces.

    For tablet, capsule, and granule products that are not supplied as solutions, the COP barrel is used as an oral dosing syringe with a press-in bottle adapter or enteral tip. The syringe measures reconstituted oral suspension after pharmacy or bedside mixing of granules, powder, or crushed tablet slurry. Low surface adsorption benefits low-dose or low-solubility actives, but formulation-specific recovery studies are required because adsorption is influenced by pH, excipient micellisation, and contact time. For oral applications, the barrel is not exposed to parenteral sterility requirements; however, the same physicochemical and biological evaluation data support compendial acceptance. Graduation marks are pad-printed or laser-etched and must remain legible after exposure to reconstitution vehicles and cleaning agents used in clinical wards.

    The following compendial and regulatory standards apply to the COP pre-filled syringe barrel in injectable and oral pharmaceutical use.

    Compliance matrix for COP pre-filled syringe barrel applications
    Standard or guidanceScopeApplied tests and limits
    ISO 11040-6Plastic barrels for injectables and sterile sub-assembled syringes ready for fillingDimensional, physicochemical, sterility barrier, and plunger functionality
    USP <661.1>Plastic materials of constructionIdentification, UV absorbance, extractable metals, non-volatile residue, buffering capacity
    USP <661.2>Plastic packaging systems for pharmaceutical useSystem-level extracts, pH shift, turbidity, biological reactivity
    Ph. Eur. 3.2.2Plastic containers and closures for pharmaceutical useClarity and colour of extracts, reducing substances, extractable residue
    ICH Q3DElemental impuritiesICP-MS screening for Class 1, 2A, 2B and 3 elements against permitted daily exposure limits
    ISO 10993-1:2018Biological evaluation of medical devicesCytotoxicity, irritation, sensitisation, and systemic toxicity endpoints as applicable
    FDA 21 CFR 177.1520Olefin polymers in contact with food and drugSupplier resin clearance cited in Type III drug master file cross-reference