| HS Code | 932207 |
| Productname | CIP Station Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Productcategory | Clean-In-Place (CIP) Station |
| Industry | Pharmaceutical |
| Grade | Pharma Grade |
| Application | Cleaning of API manufacturing equipment |
| Dosageformcompatibility | Tablet, Capsule, Granule, Injection |
| Routeofadministration | Oral, Injectable |
| Cleaningmethod | Automated CIP |
| Materialofconstruction | Stainless Steel 316L |
| Controlsystem | PLC with HMI |
| Operatingtemperaturerange | 5°C to 90°C |
| Operatingpressurerange | 1 to 6 bar |
| Flowrate | 5 to 20 m³/h |
| Tankcapacity | 100 to 1000 L |
| Compliance | cGMP, FDA, EU GMP |
| Certification | CE, ISO 9001 |
| Powersupply | 380 V / 50 Hz / 3 Phase |
| Surfacefinish | Ra ≤ 0.5 µm |
| Documentation | IQ/OQ/PQ |
| Warranty | 12 months |
As an accredited CIP Station Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | CIP Station Pharma Grade API supplied in 25 kg sealed, polyethylene-lined fiber drums with tamper-evident labels for oral/injectable use. |
| Container Loading (20′ FCL) | 20′ FCL: Pharma-grade CIP station API for tablets, capsules, granules, injections, oral and injectable use; securely loaded and packed for export. |
| Shipping | Shipped in sealed, pharma-grade containers with tamper-evident closures, under controlled temperature/humidity as per stability data. Cold-chain or ambient options available. Protected from light, moisture, and cross-contamination. Documentation includes COA, SDS, batch, and expiry. Oral and injectable grades handled under GMP/GDP and applicable transport regulations. |
| Storage | Store CIP Station Pharma Grade API in a cool, dry, well-ventilated, controlled pharmaceutical area at 15–25°C, away from direct sunlight, heat, moisture, and ignition sources. Keep containers tightly closed, upright, and clearly labeled. Protect from contamination; segregate from incompatible materials, food, and feed. For injectable-grade material, maintain sterile, tamper-evident packaging and follow GMP requirements. Refer to SDS and product label. |
| Shelf Life | Shelf life: typically 24 months when stored cool, dry, protected from light and moisture in original sealed containers, per manufacturer specifications. |
Direct compression of CIP Station Pharma Grade API into an immediate-release tablet is controlled primarily by particle size, moisture, and consolidation behavior rather than by API class alone. Particle size is adjusted so that the API D90 is not more than 100 µm and the D50 is between 10 µm and 40 µm by laser diffraction Ph.Eur 2.9.31. A production-scale Korsch XL 400 or FETTE 3200i rotary press with 43–65 stations can sustain 80,000–250,000 tablets/h only when the final blend maintains a bulk density between 0.45 g/mL and 0.65 g/mL and a compressibility index below 20% per USP <1174>. Representative direct-compression frames for low-dose APIs place the active component at 2.0–10.0 wt%, microcrystalline cellulose at 45.0–55.0 wt%, lactose monohydrate at 35.0–45.0 wt%, croscarmellose sodium at 2.0–4.0 wt%, colloidal silicon dioxide at 0.5–1.0 wt%, and magnesium stearate at 0.25–1.0 wt%. Compression force is set between 8 kN and 16 kN for 7–10 mm round tooling, targeting tablet hardness of 60–120 N and friability not greater than 1.0% after 100 revolutions under USP <1216>. Dissolution is monitored using USP <711> Apparatus II at 50 rpm in 900 mL of 37 °C ± 0.5 °C phosphate buffer pH 6.8, provided the API is BCS Class I or III; otherwise pH-solubility data determine the medium. Content uniformity is assessed under USP <905>, requiring an acceptance value not greater than 15.0 for 10 dosage units at release. Elemental impurities are controlled according to ICH Q3D, and residual solvent screening follows USP <467> and ICH Q3C. The terminal product is an immediate-release tablet with a target disintegration time below 15 min in USP <701> medium at 37 °C ± 2 °C.
With CIP Station Pharma Grade API in powder-filled hard gelatin or hypromellose capsules, fill weight drift on a Bosch GKF 2600 or MG2 Tekna tamping-pin machine is typically linked to charge bed porosity, API lot-to-lot moisture variation, and electrostatic charge. The blend for a size 3 capsule often contains 5.0–10.0 wt% API, 80.0–90.0 wt% lactose monohydrate or mannitol, 2.0–5.0 wt% sodium starch glycolate, 0.5–1.0 wt% colloidal silicon dioxide, and 0.5–1.5 wt% magnesium stearate. The fill target is set by tamping-pin compression force, not by gravimetric weight alone. Tamping pin insertion depth of 8–12 mm at a dosing disk speed of 50–100 rpm produces plug densities in the range of 0.55–0.75 g/cm³. Moisture is maintained below 2.0% by loss on drying USP <731> because hygroscopic API lots can reduce powder flow through the feed hopper and cause fill weight relative standard deviation to exceed 3.0%. Capsule shell moisture is separately held at 12–16% w/w; lower moisture increases brittleness and splitting during high-speed closing. Dissolution of the filled capsules is assessed with USP <711> Apparatus I or II, with sinkers for low-density formulations. Content uniformity follows USP <905>, and blend uniformity is verified before filling under 21 CFR 211.110. The terminal product is a hard-shell capsule with disintegration below 15 min under USP <701>.
High-shear wet granulation of CIP Station Pharma Grade API is justified when direct compression cannot deliver acceptable content uniformity at an API load below 2.0 wt% or when the API is sensitive to segregation in a low-shear tumbling mixer. Dry blending is performed in a Collette Gral-75 or equivalent 75 L vertical-shaft high-shear granulator at impeller speed 300 rpm and chopper speed 1,500 rpm for 2 min. A binder solution of 5.0 wt% povidone K30 in purified water is added at 0.5 kg/min to a total granulating fluid load of 25–35 wt% relative to dry powder weight. Wet massing continues until the impeller torque reaches 15–25 N·m, a range that correlates with granule mean size and final tablet hardness more closely than fixed massing time in scale-up records. The wet granulate is discharged through a 6.35 mm mesh and dried in a Glatt GPCG-60 fluid-bed dryer with inlet air at 55–65 °C and product temperature held between 35 °C and 40 °C to avoid degrading heat-sensitive API fractions. Final loss on drying is controlled at 1.5–2.5% by USP <731>, and milled granules are passed through a 0.8–1.25 mm conical screen using a Quadro Comil at 1,000 rpm. The resulting granule size distribution is checked by sieve analysis USP <786>, with a typical D50 between 120 µm and 180 µm and fines below 20 wt%. Extragranular crospovidone is added at 2.0 wt%, followed by magnesium stearate at 0.5 wt% for 2 min. The final granulate can be fed to a rotary tablet press at 10–20 kN for film-coated oral tablets or filled directly into foil-lined sachets as a granule product. Coating with aqueous Opadry II to 3.0–4.0% weight gain provides moisture protection and taste masking. Drug release is verified by USP <711>, residual solvents by USP <467>, and degradation impurities by ICH Q3B.
Dry granulation by roller compaction is used for CIP Station Pharma Grade API when moisture exposure during aqueous wet granulation is unacceptable or when the API exhibits poor compactability after rewetting. A Fitzpatrick CCS 220 or Alexanderwerk WP 120 roller compactor configured with smooth or knurled rolls compresses a pre-blend into ribbons at roll pressure 4–8 kN/cm, roll speed 6–10 rpm, and roll gap 2.0–3.0 mm. The pre-blend contains API at 5.0–20.0 wt%, microcrystalline cellulose at 30.0–50.0 wt%, lactose monohydrate at 30.0–50.0 wt%, croscarmellose sodium at 2.0–3.0 wt%, and a pre-lubricant portion of magnesium stearate at 0.5–1.0 wt% to reduce roll adhesion. Ribbon solid fraction is maintained between 0.60 and 0.70 by helium pycnometry or calculated from ribbon thickness and mass. Lower solid fraction increases fines during milling, while higher solid fraction can reduce tablet tensile strength due to loss of compaction potential. Milling is performed with a grate bar and rotor at 50–80 rpm, producing granules screened to 0.8–1.25 mm. After granulation, the remaining extragranular disintegrant 1.0–2.0 wt% and magnesium stearate 0.25–0.5 wt% are added in a tumble blender at 12 rpm for 2 min. Tablet hardness is evaluated at 60–100 N, dissolution by USP <711>, and content uniformity by USP <905>. The terminal product is typically an immediate-release tablet or a scored tablet with no solvent residue, which simplifies USP <467> compliance. Published data for this specific configuration is limited at extreme API loadings above 25 wt% because roll sticking and loss of blend flow dominate.
| Dosage form | Primary equipment | Critical process boundary | Compendial and GMP tests | Typical finished product |
|---|---|---|---|---|
| Direct compression tablet | Korsch XL 400 / FETTE 3200i rotary press | Blend moisture ≤2.0%; bulk density 0.45–0.65 g/mL; compression force 8–16 kN | USP <905>, USP <711>, USP <1216>, ICH Q3D | Immediate-release tablet |
| Powder-filled capsule | Bosch GKF 2600 / MG2 Tekna tamping-pin filler | Fill weight RSD ≤3.0%; plug density 0.55–0.75 g/cm³; shell moisture 12–16% w/w | USP <905>, USP <711>, USP <701>, 21 CFR 211.110 | Hard gelatin or HPMC capsule |
| High-shear granule | Collette Gral-75 / Glatt GPCG-60 fluid bed | Torque 15–25 N·m; final LOD 1.5–2.5%; granule D50 120–180 µm | USP <731>, USP <786>, USP <711>, ICH Q3C | Granule-filled sachet or compressed tablet |
| Roller-compacted granule | Fitzpatrick CCS 220 / Alexanderwerk WP 120 | Ribbon solid fraction 0.60–0.70; roll pressure 4–8 kN/cm; screen 0.8–1.25 mm | USP <786>, USP <905>, USP <711>, USP <467> | Immediate-release or scored tablet |
Oral suspension compounding with CIP Station Pharma Grade API begins with particle size reduction by air-jet milling to a D90 below 25 µm to minimize viscosity and sedimentation. The suspending vehicle contains microcrystalline cellulose and carboxymethylcellulose sodium at 1.0–2.0 wt%, sorbitol at 20.0–30.0 wt%, glycerin at 10.0–20.0 wt%, sodium benzoate at 0.1–0.2 wt%, and polysorbate 80 at 0.05–0.1 wt% as wetting agent. The API is dispersed under high-shear at 3,000 rpm for 15 min, then pH is adjusted to 4.5–5.5 with citric acid or sodium citrate to reduce zeta-potential drift. Viscosity is measured with a Brookfield RVT at 25 °C, spindle 2, 30 rpm, and controlled between 150 cP and 300 cP to provide pourability and dose uniformity. The suspension is filled into amber PET bottles with child-resistant closures at 100 mL or 150 mL volumes and dosed with graduated syringes. Release testing includes assay and dose uniformity under USP <905>, pH, and microbial limits USP <61> and USP <62>. Absence of specified objectionable organisms is documented under USP <1111>, and preservative efficacy is verified by USP <51>. The terminal product is a ready-to-use oral suspension with shelf life determined by antimicrobial effectiveness rather than by chemical stability alone.
Terminally sterilized aqueous injections containing CIP Station Pharma Grade API require a formulation route that separates bulk solution preparation from sterile filling and thermal sterilization. The bulk solution is prepared in a closed 316L stainless steel vessel at an API concentration of 5.0–20.0 mg/mL, adjusted to pH 6.0–7.0 with 0.1 N hydrochloric acid or sodium hydroxide as needed. Tonicity is corrected to 250–350 mOsm/kg with sodium chloride at 9.0 mg/mL. Nitrogen blanketing is applied when forced degradation studies show oxidative sensitivity. Pre-filtration bioburden is held below 10 CFU/100 mL, enumerated by membrane filtration per USP <61>. The bulk is double-filtered through a 0.45 µm prefilter and a 0.22 µm sterilizing-grade PVDF filter, with filter integrity tested before and after use by bubble point or diffusive flow per ASTM F838-20. Filling occurs in a restricted-access barrier system or isolator within an ISO 14644-1 Class 5 zone equivalent to EU GMP Annex 1 Grade A. Terminal sterilization is performed in a steam-air autoclave at 121 °C for 15 min, delivering an F0 value not less than 12 min per ISO 17665-1:2006. Post-sterilization testing includes sterility by USP <71>, bacterial endotoxin by USP <85>, particulate matter by USP <788>, and visible particulates by USP <790>. Endotoxin acceptance is calculated from K/M, where K = 5 EU/kg for parenterals and M is the maximum bolus dose in mL/kg. A 10 mL dose in a 70 kg adult yields M = 0.143 mL/kg and a limit of 35 EU/mL. For a 500 mL infusion, the corresponding limit is 0.7 EU/mL. pH drift is logged after terminal heating because autoclaving may shift pH by 0.2–0.4 units. The terminal product is a ready-to-use liquid in Type I borosilicate glass vials of 2 mL, 5 mL, or 10 mL, with glass tested under USP <660> and elastomeric closures tested under USP <381>.
Where CIP Station Pharma Grade API degrades under autoclave heat or hydrolyzes in aqueous solution at elevated pH, freeze-drying in Type I glass vials becomes the selected injectable route. The formulation is held at half-fill volume in 5 mL or 10 mL vials and contains the API at 5.0–20.0 mg/mL with bulking agent mannitol at 40.0–80.0 mg/mL and cryoprotectant sucrose or trehalose at 10.0–30.0 mg/mL. Freezing is performed on a Telstar LYOBETA or SP Scientific LyoStar 3 with shelf cooling to −45 °C at 0.5–1.0 °C/min and hold for 2–4 h. Primary drying shelf temperature is set 3–5 °C below the collapse temperature measured by freeze-dry microscope. For a representative collapse temperature of −32 °C, shelf temperature is held at −15 °C to −10 °C with chamber pressure at 0.10–0.20 mbar. Secondary drying is conducted at 25–40 °C for 4–8 h until cake moisture by Karl Fischer USP <921> Method I falls to ≤1.0%. Vials are stoppered under vacuum or partial nitrogen to reduce headspace oxygen and sealed with aluminum flip-off seals. Sterility is verified by USP <71>, bacterial endotoxin by USP <85>, and particulate matter by USP <788> after reconstitution. The terminal product is a lyophilized powder or porous cake labeled for reconstitution with Sterile Water for Injection to the original fill volume, producing a solution free of visible particulates under USP <790>. Batch records specify that the ice sublimation rate must not exceed the vapor removal capacity of the condenser, otherwise collapse or meltback occurs and the batch fails visual appearance and residual moisture.
Competitive CIP Station Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
The CIP Station Pharma Grade API is a modular clean-in-place skid intended for washdown of product-contact surfaces in active pharmaceutical ingredient and finished-dose manufacturing across oral solid dosage forms — tablets, capsules, and granules — and injectable production trains. The standard arrangement supplies heated process water or Water for Injection, alkaline detergent, and acid rinse media through a recirculation loop configured to clean transfer piping, reactor vessels, filter dryers, granulator bowls, fluid-bed dryer internals, tablet press subassemblies, and aseptic filling equipment. The baseline platform comprises 316L stainless steel storage capacity, a centrifugal supply pump with variable-frequency drive, a plate heat exchanger, a return pump sized for flooded suction, and a distributed I/O control cabinet. Storage volume and pump capacity are selected from a design envelope of 500 L to 10,000 L and 5 m³/h to 80 m³/h delivery, depending on the number of parallel cleaning circuits. Published data for a single named model are limited because flow rate, spray device geometry, and tank volume are configured per process train and residue profile.
Product-contact piping is specified as 316L stainless steel in DIN 11850 metric tube dimensions with orbital butt welds. Internal surface roughness average is held to ≤ 0.8 µm Ra for oral solid dosage cleaning circuits and to ≤ 0.5 µm Ra for parenteral contact after electropolishing. Dead legs are limited to an L/D ≤ 2:1 ratio under ASME BPE 2022 for cleanable branches; instrument tees are oriented upward and pitched to drain at ≥ 2% slope. Gaskets on product-contact flanges are EPDM or PTFE envelope, with a temperature envelope of −10°C to 150°C for EPDM and −20°C to 260°C for PTFE. Elastomer compliance is documented against FDA 21 CFR 177.2600 and USP <87>/<88>. Weld shielding gas during orbital welding is maintained below 1% oxygen, and borescope inspection of the final weld root is performed on a sampling basis.
For oral solid dosage equipment, the skid is applied to high-shear granulator bowls, fluid-bed dryer columns, and coating pans only after removable components are positioned in a wash cart or connected to dedicated spray lances. The cleaning sequence for a granulator bowl with a residual granulation mass of approximately 5–10 kg begins with a cold pre-rinse at 2.0 m³/h to remove gross solids and continues with a 1.5 wt% sodium hydroxide solution at 70°C for 15 min. A return-line turbidity meter monitors the pre-rinse endpoint at ≤ 10 NTU before the alkaline step is initiated. The intermediate rinse is terminated when the return pH falls to 7.0–7.5; a final rinse with ≥ 65°C purified water is continued until the return conductivity stabilizes within ±0.2 µS/cm of the supply value. The system does not clean tablet press die bores by automated interior spray; die pockets and punches require an ultrasonic bath or automated parts washer connected to the CIP skid because borescope verification of residual magnesium stearate in the die bore cannot be achieved with spray ball coverage alone.
The primary technical boundary between oral solid and injectable service is the final rinse medium and the surface finish requirement. A standard oral solids skid using purified water and ≤ 0.8 µm Ra mechanical surfaces is not interchangeable with a parenteral circuit without a validated changeover. For injectable trains, the station is supplied with Water for Injection from a distribution loop continuously recirculated at ≥ 70°C, and the final rinse is monitored for conductivity ≤ 1.3 µS/cm at 25°C and total organic carbon < 500 ppb in accordance with USP <1231> and the Water for Injection monograph. Endotoxin control is applied through the combination of Water for Injection, dried compressed air filtered at 0.2 µm, and terminal sanitization with pure steam at 121°C for 30 min only for components rated for saturated steam. The use of a single skid across both dosage form families is therefore permitted only when the final rinse manifold is isolated and the software recipe controller prevents initiation of an oral solid cleaning sequence without the correct rinse medium verification. In addition, cleaning solution temperature for injectable contact surfaces is limited to ≤ 85°C in the presence of standard EPDM gaskets, because prolonged operation above this limit increases extraction of organic elastomer compounds into the rinse water and can raise total organic carbon above the 500 ppb acceptance limit.
Automated control is achieved through a PLC/HMI package with an electronic batch record and audit trail. The minimum instrument set includes an electromagnetic flow transmitter with ±0.3% of reading accuracy, Pt100 resistance temperature detectors with ±0.1°C accuracy, two conductivity cells with temperature compensation, and pressure transmitters with ±0.25% full-scale accuracy. The software enforces critical process parameters: supply flow velocity 1.5–3.0 m/s in the main return line, return-line Reynolds number > 10,000, alkaline wash temperature 70–80°C, and final rinse conductivity ≤ 1.3 µS/cm at 25°C. Batch records include time-stamped data for each circuit, exception alarms, and user identification in accordance with FDA 21 CFR Part 11 and EU GMP Annex 11. The skid is provided with a factory acceptance test protocol that includes a hydraulic test at 1.5 times the design pressure and a loop cleanliness test; however, published data for a specific customer installation are limited and must be generated during commissioning.
| Parameter | Oral Solid Dosage Envelope | Injectable Envelope | Reference Standard |
|---|---|---|---|
| Product-contact surface roughness | ≤ 0.8 µm Ra | ≤ 0.5 µm Ra | ASME BPE 2022 |
| Main return velocity | 1.5–3.0 m/s | 1.5–3.0 m/s | — |
| Return-line Reynolds number | > 10,000 | > 10,000 | — |
| Alkaline wash | 1.0–2.0 wt% NaOH, 70–80°C, 10–20 min | 1.0–2.0 wt% NaOH, 70–80°C, 10–20 min | — |
| Final rinse conductivity | ≤ 1.3 µS/cm at 25°C | ≤ 1.3 µS/cm at 25°C | USP <1231> |
| Final rinse total organic carbon | < 500 ppb | < 500 ppb | Water for Injection monograph |
| Elastomer compliance | EPDM or PTFE | EPDM or PTFE | FDA 21 CFR 177.2600, USP <87>/<88> |
| Dead-leg ratio | L/D ≤ 2:1 | L/D ≤ 2:1 | ASME BPE 2022 |
The single-pass rinse volume is adjusted according to the mass of retained powder and the solubility of the active ingredient. For a poorly water-soluble active pharmaceutical ingredient with a solubility below 50 µg/mL, the alkaline wash step is extended to 20 min and the detergent concentration is increased to 2.0 wt%, because solubility-limited dissolution rather than fluid shear is the rate-controlling step. For water-soluble active pharmaceutical ingredients, the 1.0 wt% sodium hydroxide solution at 70°C typically achieves visual absence of residue within 10 min, but visual inspection is not accepted as a release criterion. Swab samples from granulator blades, filter-dryer discharge chutes, and tablet press turret surfaces are analyzed for active residue by a validated HPLC method with a limit of quantification below the acceptable carryover limit. The acceptable carryover limit is calculated from the permitted daily exposure, the smallest subsequent product batch size, and the shared surface area; the station itself does not perform this calculation but the recipe management software accepts a maximum residue limit entered per equipment circuit.
For compounds with an occupational exposure limit below 1 µg/m³, the standard open skid configuration is not acceptable without an engineered enclosure and negative-pressure exhaust. The cleaning pump, valve manifold, and return line are housed in a ventilated cabinet with air extract at −50 Pa relative to the surrounding room, and the operator HMI is located outside the containment zone. Rinsing of the closed process vessel is performed under inert conditions at 20–40°C only when the process residue is thermally unstable; otherwise the standard 70–80°C alkaline wash is used. The return line is fitted with a conductivity and turbidity sensor that detects breakthrough of organic residue, and the disposal line is routed to a holding tank for analytical verification before discharge. For such compounds, the system is equipped with a dedicated solid–liquid separator on the first rinse to prevent transfer of insoluble excipients into the recirculation loop. Published data for a specific potent compound cleaning operation are limited; the cleaning endpoint is established via spiking studies and swab recovery trials in accordance with ICH Q7 and EU GMP Annex 15.
Compared with food-grade or industrial clean-in-place skids, the pharma-grade unit differs in surface finish, dead-leg control, and documentation. A general-purpose skid may use 304 stainless with 0.8–1.6 µm Ra mechanical finish and clamp fittings; the pharmaceutical station uses 316L, electropolished welds, and L/D ≤ 2:1 branch design. The valve manifold is constructed with forged bodies and PTFE seats, and all product-contact valves are supplied with material test reports to EN 10204 3.1. The instrument accuracy and data storage capabilities are higher: the pharma-grade skid records flow, temperature, conductivity, and pressure every 1 s during the cleaning cycle, whereas a general-purpose skid may only record alarm states. The mechanical design is also different in drainability: the pharma-grade skid is pitch-controlled to ≥ 2% slope and uses eccentric reducers to avoid pooling, whereas industrial systems may have flat-bottom tanks and horizontal dead legs that are not acceptable for sterile processes. Another difference is the final rinse: the pharma-grade skid for injectables uses Water for Injection and verifies conductivity, total organic carbon, and endotoxin, whereas the food-grade skid typically uses potable water with no pharmacopoeial requirement.
| Attribute | General-Purpose CIP | CIP Station Pharma Grade API |
|---|---|---|
| Materials of construction | 304 stainless, 0.8–1.6 µm Ra | 316L, ≤ 0.8 µm Ra oral / ≤ 0.5 µm Ra injectable |
| Branch design | Clamp and threaded fittings; variable dead legs | Orbital welds, L/D ≤ 2:1 branch ratio |
| Instrumentation and records | Alarm-only or chart recorder | 1 s interval data logging, audit trail, electronic batch record |
| Final rinse medium | Potable water | Purified water or Water for Injection with conductivity, total organic carbon, and endotoxin verification |
| Documentation | Standard pump and tank datasheets | EN 10204 3.1, installation/operational qualification, FDA 21 CFR Part 11 |