| HS Code | 619160 |
| Productname | Bupropion HCl Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Synonyms | Bupropion hydrochloride; Amfebutamone hydrochloride |
| Chemicalname | 2-(tert-Butylamino)-3'-chloropropiophenone hydrochloride |
| Inn | Bupropion hydrochloride |
| Casnumber | 31677-93-7 |
| Molecularformula | C13H18ClNO·HCl |
| Molecularweight | 276.20 g/mol |
| Appearance | White to off-white crystalline powder |
| Odor | Practically odorless |
| Assay | 98.0% to 102.0% on dried basis |
| Identification | IR and/or HPLC retention time complies with reference standard |
| Solubility | Freely soluble in water; soluble in ethanol; slightly soluble in chloroform |
| Ph | 4.5 to 6.5 for aqueous solution |
| Meltingpoint | 233°C to 236°C with decomposition |
| Qualitystandard | Complies with USP, EP, BP, or IP pharmacopeial requirements |
| Grade | Pharma Grade API |
| Storage | Store in tight, light-resistant containers at controlled room temperature; protect from moisture |
| Shelflife | Typically 24 to 60 months when stored properly |
| Packaging | 25 kg fiber drum with double polyethylene bags |
| Therapeuticcategory | Antidepressant; smoking cessation aid |
| Mechanismofaction | Norepinephrine-dopamine reuptake inhibitor; nicotinic acetylcholine receptor antagonist |
| Routeofadministration | Oral and injectable |
| Dosageforms | Tablet, capsule, granule, injection |
| Regulatorystatus | Prescription only |
As an accredited Bupropion HCl Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Bupropion HCl Pharma Grade API for oral/injectable use packed in sealed, light-resistant, double LDPE-lined fiber drums; 25 kg net per drum. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with palletized drums of Bupropion HCl Pharma Grade API for tablet/capsule/granule/injection, oral & injectable pharmaceutical use. |
| Shipping | Bupropion HCl Pharma Grade API is shipped in sealed, light-resistant, moisture-barrier containers at controlled room temperature (15–25°C), with desiccants and temperature monitoring. Packages are handled under GMP/GDP, labeled clearly, and accompanied by COA, MSDS, and customs documentation. Suitable for oral and injectable pharmaceutical manufacturing. |
| Storage | Store Bupropion HCl Pharma Grade API in tightly closed, original containers in a cool, dry, well-ventilated area, protected from light and moisture. Maintain controlled room temperature (15–30°C/59–86°F) unless otherwise specified. Keep away from incompatible or oxidizing materials. For injectable-grade use, handle aseptically to prevent contamination. Follow USP/NF and manufacturer storage requirements. Do not use if container damaged or seal broken. |
| Shelf Life | Bupropion HCl Pharma Grade API typically has 24–36 months shelf life when stored sealed, dry, protected from light, per manufacturer specifications. |
For immediate-release bupropion HCl tablet cores, the manufacturing route is selected after evaluating the active substance’s high aqueous solubility, amine-related incompatibilities, and the need for rapid disintegration without premature release variability. The finished tablet must satisfy dissolution under USP <711>, content uniformity under USP <905>, water content under USP <921>, and friability under USP <1216>; batch release testing is performed under 21 CFR 211.165, while elemental impurity control follows ICH Q3D and residual solvent limits follow ICH Q3C. In approved immediate-release presentations, the unit dose is commonly 75 mg or 100 mg of bupropion HCl, and the active pharmaceutical ingredient mass fraction in the tablet core is typically bracketed between 40% w/w and 65% w/w, depending on the microcrystalline cellulose, pregelatinized starch, and sodium starch glycolate levels selected for the formulation. The terminal product types for this processing line are conventional immediate-release film-coated tablets intended for oral administration, normally released as round or capsule-shaped cores with a non-functional aqueous film coat.
At production scale, the raw bupropion HCl is first delumped through a vibratory screen or cone mill fitted with a 800 µm rasp screen to break soft agglomerates, after which the active is blended with filler and disintegrant in a bin blender at 20 rpm for 15 min to 20 min. Magnesium stearate is then added at 0.5% w/w to 1.0% w/w and the final lubrication step is limited to 3 min to 5 min to avoid hydrophobic film formation on the granule surfaces. If direct compression is employed, a rotary tablet press equipped with multi-tip tooling is operated at a compression force of 8 kN to 12 kN for small-diameter cores; tablet hardness is controlled between 5 kp and 8 kp, and friability must remain below 0.8%. A common production bottleneck on high-speed presses is weight variation when the active content is high because the lubricated blend can segregate if the Hausner ratio exceeds 1.4; in that situation, roller compaction is introduced before compression to increase bulk density and reduce the proportion of fines below 75 µm. The compacted ribbons are milled through a 1.0 mm screen, re-lubricated, and compressed. This dry-granulation step is also required when direct compression produces capping or lamination due to residual moisture below 1.0% w/w or excessive fine particle content.
The process limits for this dosage form include a maximum granule moisture content of 2.0% w/w when lactose-containing formulations are exposed to elevated drying temperatures; the secondary amine group of bupropion HCl can participate in Maillard browning with reducing sugars if both moisture and heat are uncontrolled, generating unacceptable color changes in the tablet core. Sodium starch glycolate levels above 5% w/w can increase water uptake and lead to premature disintegration if the film coating is cracked during pan coating; therefore coating pan speed, spray rate, and inlet air temperature are adjusted to maintain tablet bed temperature below 45°C during aqueous film application. The immediate-release manufacturing stream is the least complex downstream use of bupropion HCl, but it is also the most sensitive to powder-flow drift because the active is ordinarily present as a fine crystalline powder with poor flow and high cohesiveness unless a granulation step is introduced.
Because bupropion HCl is highly water soluble, extended-release tablets must rely on a hydrated hydrophilic matrix to slow drug diffusion, and the main process risk is the interaction between the water-soluble active and the rate-controlling polymer before compression. The unit dose is typically 150 mg or 300 mg of bupropion HCl, with active pharmaceutical ingredient mass fraction in the extended-release core generally between 30% w/w and 45% w/w depending on the matrix former content and the presence of pore formers or osmotic agents. Compliance requires a multi-point dissolution test under USP <711> with sampling intervals that verify the absence of dose dumping; content uniformity is assessed under USP <905>, and the stability program follows ICH Q1A, including long-term 25°C/60% RH and accelerated 40°C/75% RH storage. Terminal products include extended-release film-coated tablets for once-daily or twice-daily administration, with matrix systems composed of hypromellose, polyethylene oxide, or combinations of the two, often with a non-functional aesthetic film coat.
Production of the extended-release matrix begins with dry granulation rather than aqueous wet granulation when high-viscosity hypromellose is used because direct water addition can hydrate the polymer prematurely and create a gel layer that reduces granule uniformity and increases granulator torque. Roller compaction at a roll pressure of 20 kN to 40 kN per roll diameter and a gap setting between 1.5 mm and 2.5 mm produces ribbons that are screened through an oscillating mill with a 1.0 mm or 1.5 mm screen; the resulting granules are blended with extragranular polymer and lubricant before compression on a rotary press at 12 kN to 20 kN for larger cores. Hardness variation across the batch is a known source of release-rate drift because compression force directly influences matrix porosity; a spread of more than ±10% in hardness can alter the erosion rate of the hydrated gel layer and shift the 2-hour, 4-hour, and 8-hour dissolution points outside the registered specification. Film coating is performed in a side-vented pan coater, maintaining exhaust temperature at 40°C to 50°C and bed temperature below 45°C to avoid thermal stress on the matrix and to prevent premature polymer transition.
An additional failure mode at scale is tablet splitting or edge erosion during coating when the core has high friability or sharp land edges; tablet hardness above 15 kp may reduce breaking force during handling but can also slow polymer hydration and delay drug release beyond the specification. Process qualification studies therefore correlate dissolution at multiple time points with compression force, polymer grade, and lubricant mixing time. Lubricant overmixing must be avoided because hydrophobic magnesium stearate can concentrate on the granule surface and reduce water penetration into the matrix, producing a slow initial release followed by a later burst; total magnesium stearate content is maintained between 0.5% w/w and 1.0% w/w with final blend time not exceeding 5 min. The production bottleneck at scale is not active dosing, which is straightforward, but the sensitivity of the gel diffusion layer to minor density variations; therefore online hardness monitoring and periodic ribbon density measurement are used to maintain batch-to-batch dissolution consistency.
The compendial and in-process control matrix for oral solid dosage forms containing bupropion HCl is consolidated in the following table.
| Control point | Standard designation | Test method |
|---|---|---|
| Finished tablet dissolution | USP <711> | Apparatus 1 or 2 with specified medium and sampling intervals |
| Content uniformity | USP <905> | Weight variation or chromatographic assay |
| Water content | USP <921> | Karl Fischer titration |
| Tablet friability | USP <1216> | Rotating drum friabilator |
| Elemental impurities | ICH Q3D | Inductively coupled plasma-mass spectrometry |
| Residual solvents | ICH Q3C | Headspace gas chromatography |
| In-process blend uniformity | 21 CFR 211.110 | Stratified sampling with chromatographic assay |
In capsule filling operations for bupropion HCl, powder fluidity rather than compression force determines whether a batch can be filled within the required weight variation limits. Capsule-based bupropion HCl presentations are uncommon among approved products, but powder-in-capsule and pellet-filled capsule formats are used in early-phase clinical manufacturing, comparator studies, and special-access oral formulations where flexible dosing is required. The blend must flow by gravity or tamping-pin action without the densification that tableting provides; therefore bulk density, tapped density, Carr index, and angle of repose are the primary powder control variables. Values above 25% Carr index or below 0.4 g/mL bulk density typically require roller compaction or dry granulation before filling to reduce interparticle friction and improve die filling. The applicable compliance standards include USP <711> for dissolution of the filled capsule, USP <905> for uniformity of dosage units, USP <921> for water content, and ICH Q3D for elemental impurities. For a 100 mg bupropion HCl dose delivered in a size 1 capsule, the total fill weight is generally between 250 mg and 400 mg, placing the active pharmaceutical ingredient fraction in the range of 25% w/w to 40% w/w; however, no globally harmonized capsule monograph for bupropion HCl exists, so the formulation ratio is justified through development stability data rather than a compendial fixed percentage. The production sequence includes blending in a low-shear tumble mixer, delumping through a conical mill fitted with a 0.5 mm screen, and filling on a dosator-type capsule machine with fill weight variation controlled to ±3%; granule moisture is maintained below 2.5% w/w and desiccant is added to high-density polyethylene bottles to counteract moisture ingress. Terminal product types are hard gelatin or hypromellose capsules for investigational use, bioequivalence studies, or pharmacy compounding under controlled regulatory authorization.
The capsule route imposes a additional constraint on the empty shell itself because bupropion HCl is a secondary amine salt and can interact with residual aldehydes in gelatin under humid conditions, increasing the risk of shell crosslinking and dissolution slowdown. This is managed by qualifying shell suppliers using a dissolution test in the presence of an enzyme-free neutral medium; if the capsule shell shows delayed rupture, the formulation is shifted to a hypromellose shell or a desiccant-protected packaging configuration. Fill weight variability is aggravated by static charge accumulation when the active is spray-dried or micronized; the addition of colloidal silicon dioxide at 0.5% w/w to 1.0% w/w and the use of grounded filling machine contact parts reduce agglomerate formation. Batch-to-batch variance in the incoming active particle size also shifts the fill weight distribution, so the active is controlled by a particle size specification under USP <786> and rejected if the volume median diameter falls outside the qualified range.
When bupropion HCl is incorporated with naltrexone HCl in a fixed-dose extended-release tablet, the process design must solve two competing constraints: the low-dose naltrexone component must remain uniformly distributed, and the high-dose bupropion component must be embedded in the same matrix without accelerating its release. The approved combination strength contains 90 mg bupropion HCl and 8 mg naltrexone HCl per tablet, giving a mass ratio of 11.25:1 and a maintenance dose of 180 mg bupropion HCl and 16 mg naltrexone HCl daily from two tablets. Compliance testing includes dissolution of both actives under USP <711>, content uniformity for naltrexone under USP <905>, chromatographic assay under USP <621>, and stability testing under ICH Q1A; the finished product must also meet the general current good manufacturing practice requirements of 21 CFR 210 and 21 CFR 211. The process uses roller compaction to avoid aqueous granulation because naltrexone HCl is present at low mass and can be lost or segregated during wet mass transfer. A pre-blend of naltrexone HCl with microcrystalline cellulose is prepared in a high-shear mixer at 200 rpm for 10 min before adding bupropion HCl and the extended-release polymer; the final blend is compacted into ribbons and milled through a 1.0 mm screen, then compressed into oval film-coated tablets at 15 kN to 22 kN. Segregation risk is assessed by sampling the final blend at multiple bin heights; naltrexone assay variability above 5% RSD triggers a blend time or sieve cut adjustment. Terminal products are fixed-dose extended-release tablets for adjunctive obesity pharmacotherapy in labelled markets.
Dissolution interference between the two actives is not generally controlled by a single medium; both the bupropion and naltrexone release profiles must be monitored and reported because the low-dose component can diffuse independently from the matrix. The presence of naltrexone at low mass fraction requires a geometric pre-blend ratio not exceeding 1:5 for the first dilution step, followed by stepwise addition to the bupropion blend to avoid content uniformity failure. Coating with a non-functional aqueous film is performed after core compression; the aqueous polymer dispersion can raise the moisture content of the matrix, so tablet bed temperature is maintained below 45°C and the inlet air humidity is kept below 10 g/kg dry air. At production scale, the main failure mode is naltrexone demixing in the bin blender when the pre-blend is added too quickly or when the final blend is discharged through a long drop height; therefore discharge is performed with a laminar-flow chute or split-valve system to minimize particle-size-based segregation. The extended-release fixed-dose combination retains the same process sensitivity as single-agent extended-release tablets, but the analytical burden is doubled because the dissolution profile of both actives must fall within the registered specification window at each sampling point.
For oral suspension and sachet granules, the absence of a compaction step means that the release mechanism is controlled by the granule binder matrix or by drug coating onto sugar spheres rather than by tablet hardness. Bupropion HCl granules intended for sachet filling or bottle reconstitution must be designed for rapid suspension without aggregation, which places constraints on particle size distribution, wetting agent concentration, and residual moisture. A sachet formulation containing 75 mg or 150 mg bupropion HCl in a total sachet mass of 1.5 g to 2.0 g places the active pharmaceutical ingredient mass fraction at approximately 5% w/w to 10% w/w; the remaining mass consists of maltodextrin, modified starch, citric acid buffer, and a taste-masking polymer. The applicable compliance standards include USP <786> for particle size distribution, USP <921> for water content, USP <711> for dissolution, and USP <905> for content uniformity of the filled sachet. The production process uses a top-spray fluid-bed granulator with inlet air temperature between 55°C and 65°C, spray rate controlled between 5 g/min and 15 g/min, and final granule moisture below 2.0% w/w; after drying, granules are milled through a 1.0 mm screen and filled into sachets with fill weight variation below ±5%. Terminal product types include dry powder for oral suspension and unit-dose sachets for clinical trial administration, not widely commercialized as approved products in major markets.
Granulation from aqueous binder solutions introduces a process risk because prolonged exposure of the active to moisture and elevated temperature can promote degradation or color development; the use of reducing sugars in the granulation vehicle is avoided because the secondary amine of bupropion HCl can undergo Maillard reactions at drying temperatures. High-shear granulation at impeller speeds above 400 rpm can generate fines and cause granule size bimodality, leading to suspension inhomogeneity and dose variability across the sachet fill. The final product is protected from moisture by foil laminate sachet material with a moisture vapor transmission rate below 0.1 g/m²/day; if higher-transmission material is used, desiccant overpacking and a shorter shelf life are required. Fluid-bed granulation is preferred over high-shear granulation when a low-density porous granule is needed for rapid redispersion in water, but the fluid-bed process is less forgiving to spray-rate drift, and a spray rate excursion above the target range can produce overwet bed collapse and loss of batch yield. The granule route remains a specialist development format for bupropion HCl rather than a standard commercial line, and published data for this specific configuration is limited.
An injectable presentation of bupropion HCl is not described by a leading compendial monograph in major markets, and no commercial parenteral product has been authorized as a reference standard; therefore a manufacturer entering this application must generate formulation-specific data to support the investigational route. The applicable sterile product standards include USP <1> for injectable dosage forms, USP <71> for sterility, USP <85> for bacterial endotoxins, USP <788> for subvisible particulate matter, USP <790> for visible particulates, and USP <381> for elastomeric closure compatibility. Because no fixed formulation ratio exists in a public monograph, a development formulation may select a starting concentration such as 10 mg/mL bupropion HCl for dose-ranging, but this value must be justified by delivered dose, solution pH, osmolality, and syringeability rather than by compendial precedent; published data for this specific configuration is limited. The production process is aseptic filtration through a 0.22 µm polyvinylidene fluoride or polyethersulfone filter, followed by filling into sterile glass vials under ISO 5 conditions; terminal sterilization is not automatically applicable because the thermal stability of the drug in aqueous solution must be demonstrated before steam sterilization can substitute for filtration. Terminal product types are single-use parenteral vials for investigational use only, with container closure integrity verified by USP <1207> vacuum decay or dye ingress methods.
The main operational boundary for injectable development is the absence of approved clinical safety data for parenteral administration; bupropion HCl is associated with a dose-related seizure threshold effect, and local injection site tolerability data are not available in the public literature. The pH of an aqueous solution of the hydrochloride salt should be measured and adjusted with dilute hydrochloric acid or sodium hydroxide to a physiologically compatible range; osmolality is controlled between 270 mOsm/kg and 320 mOsm/kg when isotonicity is intended, and buffer capacity is minimized to reduce pain on injection. Filter compatibility is evaluated by measuring assay recovery and impurity profile before and after passage through the membrane; adsorptive losses above 5% require a change in filter polymer or an increase in filtration volume discard. The container closure system must not contain latex, and the stopper must be subjected to an extraction study to quantify leachable compounds under accelerated storage; if the solution is stored at 2°C to 8°C, the stability program must establish the time to first degradation product crossing the reporting threshold under ICH Q3B. The injectable scenario remains an exploratory development route rather than a standard commercial monograph application.
The injectable control matrix is summarized below for a development-stage parenteral formulation.
| Control point | Standard designation | Method |
|---|---|---|
| Sterility | USP <71> | Membrane filtration |
| Bacterial endotoxins | USP <85> | Kinetic chromogenic LAL |
| Subvisible particulate matter | USP <788> | Light obscuration particle count |
| Visible particulates | USP <790> | Manual and automated visual inspection |
| Elastomeric closure compatibility | USP <381> | Extraction and functional testing |
| Container closure integrity | USP <1207> | Vacuum decay or dye ingress |
| Sterile filtration | USP <1> | Bacterial retention validation with 0.22 µm membrane |
Competitive Bupropion HCl Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
Bupropion hydrochloride pharma grade active pharmaceutical ingredient is supplied as a white or almost white crystalline powder with molecular formula C13H18ClNO·HCl and molar mass 276.20 g/mol. The material is manufactured under ICH Q7 and is suitable as an input for immediate-release tablets, hard gelatin capsules, oral granules, and injectable dosage forms after route-specific processing. Identity is confirmed by infrared absorption and HPLC retention-time matching against the current USP/NF bupropion hydrochloride monograph. The release specification includes assay at 98.0%–102.0% on dried basis, related substances by HPLC, water content by Karl Fischer, residue on ignition, residual solvents, and microbial enumeration. Product variants are typically distinguished by particle-size grade, residual solvent class, and whether injectable-grade endotoxin and bioburden testing is included. Particle-size distribution is not fixed in the monograph; the D10/D50/D90 profile is matched to the intended unit operation. Direct compression and capsule filling commonly require a free-flowing grade, while injectable processing requires controlled endotoxin and particulate matter rather than a micronized particle-size target if the API is fully dissolved before sterile filtration. Residual solvent acceptance follows USP <467> or Ph. Eur. 5.4, with limits set according to ICH Q3C. Stability data are generated under ICH Q1A and supplied with batch release documents and a drug master file or CEP where applicable. The API is not a final dosage form; it must be formulated, processed, and tested by the receiving manufacturer under 21 CFR 211 or EU GMP Part II.
Particle-size distribution is the main split variable among tablet, capsule, and granule processes. On production-scale rotary tablet presses using B-tooling, a lot-to-lot shift in D50 above 150 µm or below 50 µm alters die fill consistency and increases tablet weight coefficient of variation. Direct compression formulations are blended in bin blenders at 70%–80% nominal fill volume; stratified sampling at the top, middle, and bottom of the blender is used to demonstrate blend uniformity before press start-up. Powder flow is evaluated with USP <1174> or Ph. Eur. 2.9.36; when Carr index is above 35%, dry granulation by roller compactor or wet granulation in a high-shear granulator is required to improve flow and reduce segregation. Because the salt has substantial aqueous solubility, aqueous wet massing requires a fixed granulation-liquid ratio and rapid drying in a fluid-bed dryer; uncontrolled overwetting can cause partial dissolution and recrystallization, which shifts the granule size distribution and increases sticking in the mill. Granules are commonly milled through a 0.5–1.0 mm screen and dried to a loss on drying of 1%–3%. Hard gelatin capsule filling with dosator or tamping-pin machines requires consistent bulk density; fill weight drift across 100,000-capsule batches is managed by controlling API particle-size and lubricant mixing. Magnesium stearate is added at 0.5%–1.0% w/w and blended for 3–5 min; longer blending reduces tablet tensile strength and delays dissolution because of hydrophobic surface coating. Finished tablet dissolution is measured with USP <711> Apparatus II at 50–75 rpm in 900 mL of 0.1 N hydrochloric acid; bupropion hydrochloride exhibits high acidic aqueous solubility, so immediate-release products typically release rapidly unless a functional coating or release-modifying excipient is applied. Content uniformity is assessed with USP <905>. Where a direct compression grade is used, the API is commonly pre-blended with microcrystalline cellulose and anhydrous dicalcium phosphate before final mixing. Loss on drying and particle-size shift during storage are controlled at or below 60% relative humidity; published long-term stability data specific to open handling of this API are limited.
Scale-up from pilot to production is not linear for bupropion hydrochloride because the drug substance’s solubility and narrow particle-size profile interact with granulation wetting. In pilot high-shear granulators at 25 L bowl volume, the water addition rate may be set as a fixed percentage of dry mass; transferring to a 300 L production bowl changes the wetting rate per unit mass and may require a lower water addition rate to avoid overgranulation. NIR moisture monitoring at the granulator outlet and at the fluid-bed dryer exhaust is used to terminate drying at the same granule moisture endpoint. If NIR is unavailable, multiple loss-on-drying samples are pulled and the fluid-bed inlet air temperature is maintained below the degradation onset temperature of the API as established by DSC. Compression speed on a high-speed rotary press is limited by the flow of the final blend; tooling condition, punch penetration depth, and pre-compression force are set during process qualification. Poor flow is typically observed as tablet weight variability exceeding 2.0% RSD at start-up; the corrective action is to adjust particle-size distribution or increase lubricant-free blending rather than to increase compression force.
| Attribute | Oral tablet/capsule | Granule | Injectable | Compendial reference |
|---|---|---|---|---|
| Identification | IR and HPLC retention time | IR and HPLC retention time | IR and HPLC retention time | USP <197>; Ph. Eur. 2.2.24, 2.2.29 |
| Assay | HPLC, anhydrous basis | HPLC, anhydrous basis | HPLC, anhydrous basis | USP <621>; Ph. Eur. 2.2.29 |
| Water content | Karl Fischer | Karl Fischer | Karl Fischer | USP <921>; Ph. Eur. 2.5.12 |
| Residual solvents | Headspace GC | Headspace GC | Headspace GC | USP <467>; Ph. Eur. 5.4; ICH Q3C |
| Microbial limits | Total aerobic count, yeast/mould | Total aerobic count, yeast/mould | Bioburden before sterilisation | USP <61>, <62>; Ph. Eur. 2.6.12, 2.6.13 |
| Endotoxin | Not routinely required | Not routinely required | Required; limit derived from dose | USP <85>; Ph. Eur. 2.6.14 |
| Particulate matter | Not applicable | Not applicable | Final solution meets ≤6000 particles ≥10 µm and ≤600 particles ≥25 µm per container for ≤100 mL | USP <788>; Ph. Eur. 2.9.19 |
| Sterility | Not applicable | Not applicable | Sterile filter 0.22 µm; aseptic fill | USP <71>; Ph. Eur. 2.6.1 |
When an injectable bupropion hydrochloride dosage form is developed, oral-grade release data are insufficient. The API must be tested for bacterial endotoxins, bioburden, subvisible particulate matter, and sterility of the finished solution. Endotoxin limit is not supplied by the bupropion hydrochloride monograph; it is calculated from the maximum single dose and patient weight. Under USP <85>, the threshold pyrogenic dose K is 5 EU/kg; the limit for the formulation is K divided by the maximum dose per kilogram. If the API is used to prepare an injectable solution, the final bulk solution is passed through a sterilising-grade 0.22 µm membrane filter and the filter is integrity-tested by bubble point or diffusion flow before and after use. Aseptic filling is conducted under EU GMP Annex 1 Grade A conditions. Subvisible particulate matter in the final container is controlled at ≤6000 particles ≥10 µm and ≤600 particles ≥25 µm per container for containers with volume ≤100 mL according to USP <788>. The API may be non-sterile before processing; terminal sterilization is possible only if the solution is compatible with the chosen terminal cycle, otherwise aseptic manufacturing is required. Because published data for bupropion hydrochloride injection formulations are limited, the formulator must develop stability-indicating methods and verify that the hydrochloride salt does not precipitate or degrade in the selected pH and vehicle. Aqueous solutions intended for injection should be protected from light and oxygen; no pharmacopeial injectable monograph currently establishes a fixed pH range for bupropion hydrochloride, so pH and buffer selection are justified by forced-degradation and accelerated stability data. For injectable development, the API batch records should document endotoxin, bioburden, and residual solvent results, not merely oral solid limits.
The hydrochloride salt is differentiated from bupropion hydrobromide primarily by molar mass and base content. The bupropion base has a molar mass of approximately 239.7 g/mol; the hydrochloride salt has a molar mass of 276.20 g/mol, yielding a base fraction of about 0.868. The hydrobromide salt has a higher formula mass, yielding a base fraction of approximately 0.749. On this basis, 174 mg of bupropion hydrobromide corresponds to approximately 150 mg of bupropion hydrochloride. When a manufacturer switches between salts, the chromatographic assay procedure, label claim, tablet weight, and dissolution tolerances must be revalidated because the salt form changes the mass of active substance required to deliver the same bupropion base dose. The product also differs from non-GMP technical-grade bupropion in impurity control, documentation, and supply-chain qualification. Technical-grade material is not manufactured under ICH Q7, may lack classified residual solvent data, and cannot be used in pharmaceutical products under 21 CFR 211 or EU GMP Part II. Pharma-grade API is released with batch-specific certificates of analysis, stability data under ICH Q1A, change-control history, and where applicable a certificate of suitability to the European Pharmacopoeia or a US drug master file. For oral solid processing, the API is supplied with a defined particle-size distribution and is compatible with direct compression, dry granulation, or wet granulation; for injectable formulation, the same chemical entity is supplied with additional endotoxin and bioburden controls. The material should not be considered interchangeable with bupropion base unless salt-to-base conversion and dissolution behaviour are revalidated.
Handling and storage are controlled to preserve compendial identity and assay. The API is stored in a tightly closed container at controlled room temperature and protected from light. Open processing at relative humidity above 60% may require moisture monitoring because powder flow and granule drying endpoints are affected by ambient moisture; if the dosage form contains moisture-sensitive excipients, pre-drying of the API to a defined loss on drying is completed before weighing. Avoid direct contact with strong oxidising agents; the API should be charged into clean, dry stainless-steel or HDPE containers. For extended processing campaigns, in-process particle-size and moisture checks are performed at campaign start, middle, and end. Batch records should document screen size for delumping, blender charge order, lubricant mixing time, and tablet press speed. If an injectable formulation is developed, the manufacturer should retain samples for sterility and endotoxin retesting and should qualify all product-contact filters for extractables and leachables. Published data for long-term bupropion hydrochloride injection stability are limited, so stability-indicating methods must be generated during process development instead of relying on oral solid compendial methods.