| HS Code | 878705 |
| Product Name | Bioreactor Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable |
| Product Category | Pharmaceutical Active Pharmaceutical Ingredient |
| Grade | Pharma Grade |
| Api Type | Bioreactor-Derived Active Pharmaceutical Ingredient |
| Dosage Forms | Tablet, Capsule, Granule, Injection |
| Route Of Administration | Oral, Injectable |
| Therapeutic Use | As per approved pharmaceutical application |
| Physical Form | Powder or Sterile Powder |
| Appearance | As per product specification |
| Purity | As per Certificate of Analysis |
| Solubility | As per product specification |
| Storage Conditions | Store in a cool, dry, protected area; sterile form as per label |
| Packaging | Pharma-grade sealed container; injection form in sterile vial |
| Shelf Life | As per manufacturer stability data |
| Manufacturing Method | Bioreactor fermentation and downstream purification |
| Quality Standards | GMP, ISO, and pharmacopoeial compliance |
| Regulatory Status | Pharmaceutical API grade |
| Target Industry | Pharmaceutical manufacturing |
As an accredited Bioreactor Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Bioreactor Pharma Grade API packaged in 25 kg double polyethylene-lined fiber drums, sealed and labeled for oral and injectable use. |
| Container Loading (20′ FCL) | 20′ FCL contains pharma-grade bioreactor API, sealed drums, palletized and secured, suitable for tablets, capsules, granules, oral and injectable applications. |
| Shipping | Shipped under GDP-compliant, temperature-controlled conditions (2–8°C or ambient as specified) in sealed, tamper-evident, moisture-barrier packaging. Validated cold-chain and data loggers maintain stability. Clearly labeled, with MSDS, CoA, and customs documentation. Handle as pharmaceutical API for oral and injectable use; protect from light, heat, and contamination during transit. |
| Storage | Store in tightly closed, original, labeled containers in a clean, dry, well-ventilated, controlled area at 15–25°C (59–77°F), protected from light, moisture, heat, and contamination. Keep away from incompatible substances. Maintain segregation of oral and injectable grades, use first-in-first-out, and ensure proper documentation. For injectable use, preserve container integrity and pyrogen-free conditions. |
| Shelf Life | Typically 24–36 months when stored sealed, dry, protected from light, at controlled temperature, per manufacturer’s stability data and certificate of analysis. |
High-shear wet granulation is applied when the API has poor flow or low bulk density and direct compression cannot meet content uniformity. In a vertical high-shear mixer, dry blend is loaded to 50–70% of bowl volume and premixed at impeller speed 100–200 rpm; binder solution is then added at 10–25 g/min per kg dry mass. The binder is usually povidone K30 or hypromellose at 3%–5% w/w in purified water, with viscosity between 5 mPa·s and 50 mPa·s measured at 25°C. Endpoint is controlled by impeller torque rise from dry-mix baseline to a target range of 20–35% additional motor load; wet mass density of 0.45–0.60 g/mL and median granule size 150–400 µm are concurrently measured. Overgranulation above 0.70 g/mL wet mass density produces dense granules that require high main compression force and delay dissolution beyond Q = 30 min. Under-granulation below 0.40 g/mL results in fines above 40% under 75 µm, poor flow, and tablet weight variation above ±3%. The wet granulation route is incompatible with APIs that undergo ester hydrolysis in aqueous binder; for such materials binder solvent is changed to ethanol or isopropanol, and the granulator is inerted to control explosion risk per ATEX 2014/34/EU and NFPA 480. Drying in a fluid-bed dryer is performed with inlet air temperature between 50°C and 65°C for thermostable APIs, but reduced to 40–50°C when the API shows solid-state degradation above 60°C. Loss on drying target after drying is 0.5%–2.0%, and residual granule moisture outside this range changes tablet hardness and dissolution. Milled granules are lubricated with 0.5% magnesium stearate and compressed to hardness 8–15 kp; friability is maintained below 0.3% per USP <1216>. Dissolution testing per USP <711> is paired with granule porosity measured by mercury intrusion; a decrease in granule intragranular pore diameter from 5 µm to 2 µm correlates with a drop in release at 10 min from 85% to 60%.
| Route | Critical parameter | Production range | Test method / equipment |
|---|---|---|---|
| Direct compression | Main compression force | 8–18 kN | Rotary tablet press; USP <1217> |
| Direct compression | Blend bulk density | 0.35–0.55 g/mL | USP <616> |
| High-shear wet granulation | Impeller torque endpoint | 20–35% above dry baseline | Vertical high-shear mixer torque sensor |
| High-shear wet granulation | Wet mass density | 0.45–0.60 g/mL | Automated wet mass density analyzer |
| Roller compaction dry granulation | Roll pressure | 30–80 bar | Production roller compactor |
| Roller compaction dry granulation | Ribbon relative density | 0.60–0.80 | Helium pycnometry |
For parenteral dosage forms, the initial manufacturing decision is whether the bioreactor-derived API can survive terminal steam sterilization without unacceptable degradation. Aqueous solutions are filled into borosilicate Type I glass vials or prefillable syringes and subjected to moist heat sterilization at 121°C for 15 min when the nominal F0 is ≥ 15 min; for heat-sensitive APIs a lower temperature cycle of 115°C for 30 min with F0 ≥ 8 min is evaluated under ICH Q8 design space. The formulation pH is buffered to the region of maximum API solution stability, typically within ±0.2 pH units of the validated set point, and ionic strength is kept below 200 mOsm/kg when tonicity adjustment with sodium chloride or mannitol is required. Terminal sterilization cannot be applied when the API demonstrates more than 2.0% total impurities after the cycle; forced degradation studies per ICH Q1A(R2) and ICH Q1B are used to set acceptance criteria. Published data for this specific API and formulation configuration is limited; the F0 acceptance criterion is therefore confirmed by combining chemical degradation data with spore challenge results from ISO 11138-3:2017. For APIs that cannot tolerate such conditions, aseptic manufacturing is used: the bulk solution is passed through 0.22 µm PVDF or PES membrane filters under differential pressure below 0.8 bar, with filter integrity tested by water intrusion or bubble point according to ISO 2942 or ASTM F838-20. The fill environment is maintained at ISO 5 class air per ISO 14644-1:2015, with viable monitoring limits of <1 CFU/m³ and non-viable particles ≥ 0.5 µm limited to 3,520 particles/m³. Stoppers are washed and sterilized by steam at 121°C for 30 min, and vials are depyrogenated in a dry-heat tunnel at 250°C with dwell time sufficient to achieve a 3-log endotoxin reduction per USP <85>. Finished product sterility is tested per USP <71>, bacterial endotoxin limit is set at ≤ 0.20 EU/mg for injectable small molecules or ≤ 0.25 EU/mL for a 1 mL parenteral dose, and subvisible particles are controlled under USP <788> at ≥ 10 µm no more than 25 particles/container and ≥ 25 µm no more than 3 particles/container for small-volume parenterals. Liquid injectables must also exclude leachable compounds from the rubber stopper; extractables testing follows ICH Q3D elemental impurity limits and USP <381> elastomeric closure requirements.
| Quality attribute | Test method / standard | Limit | Equipment / condition |
|---|---|---|---|
| Sterility | USP <71> | No growth | Membrane filtration, 14 days |
| Bacterial endotoxin | USP <85> | ≤ 0.20 EU/mg or ≤ 0.25 EU/mL | LAL kinetic chromogenic |
| Subvisible particles | USP <788> | ≥ 10 µm: ≤ 25/container; ≥ 25 µm: ≤ 3/container | Light obscuration |
| Filter integrity | ASTM F838-20 / ISO 2942 | Bubble point above validated minimum | 0.22 µm membrane |
| Residual moisture, lyophilized product | Karl Fischer | ≤ 1.0% w/w | Coulometric titrator |
| Environmental viable airborne | ISO 14644-1:2015, Annex A | ISO 5: <1 CFU/m³ | Active air sampler |
Competitive Bioreactor Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.
We will respond to you as soon as possible.
Tel: +8618963613625
Email: sales10@sinochem-nanjing.com
Flexible payment, competitive price, premium service - Inquire now!
The bioreactor-derived API is supplied under model designation BRX-PG-500 as a sterile-filtered, lyophilized or spray-dried powder for solid oral and injectable dosage forms. The product is manufactured in a closed single-use stirred-tank bioreactor train followed by depth filtration, tangential flow filtration, and packed-bed hydrophobic interaction chromatography to reduce host cell protein, nucleic acid, and endotoxin load. Certificate of analysis ranges include appearance white to off-white powder, water content by Karl Fischer titration ≤ 1.0%, and assay on anhydrous, solvent-free basis 98.0–102.0% by Ph. Eur. 2.2.20 or USP <621>. Residual host cell protein is documented at ≤ 100 ppm by a validated ELISA, and residual DNA at ≤ 10 ppb by qPCR. The product is differentiated from raw fermentation broth by the absence of added animal-derived raw materials and by compliance with ICH Q7 active pharmaceutical ingredient expectations for upstream and downstream segregation.
At the upstream processing boundary, dissolved oxygen is maintained at 30–40% saturation and pH at 6.8–7.2 using phosphate-buffered feed. The production bioreactor jacket is controlled to ±0.5 °C around the set point; excursions beyond +1.0 °C for more than 15 minutes trigger batch quarantine in accordance with ICH Q7 Section 12.4. Harvest broth is clarified through a two-stage depth filter followed by a 0.2 µm bioburden reduction membrane before chromatography. The downstream train includes anion-exchange chromatography in flowthrough mode, cation-exchange chromatography in bind-elute mode, and hydrophobic interaction chromatography. Tangential flow filtration is performed with a 100 kDa regenerated cellulose cassette; transmembrane pressure is held at 0.8–1.2 bar and crossflow flux at 10–15 LMH to minimize protein aggregation. Each batch is filtered through a 0.2 µm sterilizing-grade filter into depyrogenated stainless steel collection vessels.
Compendial compliance indicators are checked against the following test designations. The table is limited to release specifications that are systematically verified for each batch.
| Quality attribute | Method or standard | Documented specification |
|---|---|---|
| Bacterial endotoxins | USP <85> | ≤ 0.5 EU/mg injectable grade |
| Sterility | USP <71> | Meets test when labelled sterile injectable grade |
| Microbial enumeration | USP <61> | ≤ 10² CFU/g total aerobic microbial count |
| Specified microorganisms | USP <62> | Absence of Escherichia coli, Salmonella, Pseudomonas aeruginosa, Staphylococcus aureus |
| Residual solvents | USP <467> | Class 3 solvents ≤ 0.5% individually; Class 2 solvent acetone ≤ 50 ppm |
| Particulate matter | USP <788> | Meets light obscuration particle count test for injectable grade after reconstitution |
| Water content | USP <921> Method Ic | ≤ 1.0% |
| Residue on ignition | USP <281> | ≤ 0.2% |
In direct compression and dry granulation workflows, the oral-grade API is partially pre-compacted on a roll press with a roll diameter of 200 mm, a gap of 1.0–1.5 mm, and a specific compressional force of 4–6 kN/cm. Powder flow is characterized by compressibility index and Hausner ratio under USP <1174>. The oral grade is controlled to compressibility index ≤ 25% and Hausner ratio ≤ 1.35. Bulk density is documented at 0.35–0.50 g/mL and tapped density at 0.45–0.65 g/mL. Particle size by laser diffraction under USP <429> is controlled to D10 ≥ 5 µm, D50 20–40 µm, and D90 ≤ 80 µm for direct compression grades. Tabletability on a single-punch instrumented press at 150 MPa compaction pressure produces tensile strength 1.8–2.4 MPa with microcrystalline cellulose and croscarmellose sodium. Wet granulation with aqueous binder systems requires the API to be pre-blended with a hydrophobic flow aid to avoid localized hydration of amorphous surface layers.
Injectable workflows impose an additional depyrogenation requirement not applied to oral grades. The injectable-grade API is subjected to anion-exchange membrane chromatography under aseptic conditions in an ISO 14644-1:2015 Class 7 cleanroom with Grade A local protection for open product handling. Endotoxin reduction is verified by USP <85> using limulus amebocyte lysate kinetic chromogenic method; the release specification is ≤ 0.5 EU/mg. Sterile filtration is performed through a 0.2 µm polyethersulfone filter validated for ≥ 10⁷ CFU/cm² Brevundimonas diminuta retention under ASTM F838-20. Post-filtration integrity is tested by diffuse flow and bubble point per filter manufacturer protocol. The injectable API is filled into Type I borosilicate glass vials with a fill volume of 10 mL or 20 mL, partially stoppered, and lyophilized. Lyophilization primary drying is controlled at shelf temperature −30 °C and chamber pressure 0.15 mbar; secondary drying is ramped to 25 °C for 6–8 hours. Reconstituted solution clarity is assessed against Ph. Eur. 2.2.1 and particulate matter by light obscuration under USP <788>. The injectable grade is not interchangeable with oral grade because the latter has not been depyrogenated to the same limit and may fail the injectable endotoxin criterion.
Storage of the dual-grade API at relative humidity above 60% requires pre-drying before weighing and dispensing. The material is hygroscopic above 40% RH; open handling longer than 30 minutes in an uncontrolled environment can increase water activity above 0.2. Aqueous granulation fluids should be buffered to pH 4.5–5.5 to minimize hydrolytic degradation. The API should not be blended with reducing sugars such as lactose monohydrate in aqueous conditions above 40 °C because Maillard degradation forms colored adducts and reduces assay. Avoid combination with amine-based disintegrants in liquid binder systems due to pH shift and potential adduct formation. Double polyethylene bag packaging with desiccant is used; the unopened shelf life is assigned 24 months at −20 °C for the injectable grade and 36 months at 2–8 °C for the oral grade, with retest every 12 months.
Granule and capsule operations benefit from a controlled span of the particle size distribution. The oral grade is micronized only when capsule payload uniformity requires D90 ≤ 20 µm; otherwise the standard milled grade is used to avoid electrostatic adhesion to gelatine or hypromellose capsule shells. Capsule filling on a dosator nozzle system at 3,000–6,000 capsules/h achieves mass uniformity within ±3% when the API is pre-blended with 0.5% colloidal silicon dioxide and 10% pregelatinized starch. Roller compaction with lactose monohydrate and crospovidone at 6 kN/cm produces ribbons with solid fraction 0.55–0.65; milling through a 1.0 mm screen yields granules with D50 200–350 µm. The granules are suitable for tablet compression at 60–80 N hardness on a rotary press. Dissolution is tested using USP <711> Apparatus II at 50 rpm in 900 mL of pH 6.8 phosphate buffer; release at 30 minutes is documented at ≥ 80% for immediate-release tablet formulations.
Compared with non-bioreactor synthetic API routes, the microbial fermentation platform yields a chiral purity profile that is controlled by enzymatic specificity rather than by asymmetric catalysis. Synthetic routes may achieve residual solvent within USP <467> options, but they do not generate lipopolysaccharide-related pyrogen loads; however, they can generate genotoxic impurities requiring tighter control under ICH M7. The bioreactor API retains host cell protein and nucleic acid impurities that require chromatographic clearance; non-bioreactor synthetic products instead require control of palladium, copper, or organocatalyst residues under USP <232> and USP <233>. Published data for this specific configuration are limited to manufacturer process validation summaries and certificate-of-analysis trend reports; independent peer-reviewed data are not available for the BRX-PG-500 designation. The principal operational difference is that the BRX-PG-500 purifies a fermentation-derived product rather than crystallizing a synthetic intermediate, which changes the impurity profile from catalyst and solvent residues to host cell proteins, endotoxin, and fermentation media components.
| Comparison parameter | BRX-PG-500 bioreactor API | Conventional synthetic API | Raw fermentation broth |
|---|---|---|---|
| Endotoxin load | ≤ 0.5 EU/mg injectable grade | Typically below detection limit | May exceed 10 EU/mg |
| Host cell protein | ≤ 100 ppm | Not applicable | 1,000–10,000 ppm |
| Residual DNA | ≤ 10 ppb | Not applicable | Detectable above 100 ppb |
| Primary impurity clearance unit operations | Anion-exchange, cation-exchange, hydrophobic interaction chromatography | Recrystallization, distillation, carbon treatment | None |
| Compendial release testing | USP <61>, <62>, <71>, <85>, <429>, <467>, <788> | USP <231>, <232>, <233>, <467> | No release testing |
In blending validation studies on a 600 L bin blender, the BRX-PG-500 oral grade achieved blend uniformity with relative standard deviation ≤ 5% after 10 minutes at 12 rpm. However, the injectable grade is not evaluated in bin blending because the dosage form is solution or lyophilizate. For tablet and capsule use, the oral grade is ordered with a specified particle size range and residual moisture limit; the injectable grade is supplied with a higher degree of depyrogenation and is filled aseptically. The two grades are not interchangeable in the same manufacturing line without a documented cleaning verification. Cleaning validation uses swab sampling and visual inspection with a maximum allowable carryover based on 10 ppm of the next product, evaluated by high-performance liquid chromatography under ICH Q3D risk assessment. At production scale, batch-to-batch variability of the oral grade is monitored for bulk density, tapped density, and particle size D50; the manufacturer reports a batch-to-batch relative standard deviation of ≤ 6% for these powder attributes in the latest annual product quality review.