Products

ARC-Series Maglev Pump-ARC-0600 Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: ARC-Series Maglev Pump-ARC-0600 Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 740226
    Product Name ARC-Series Maglev Pump-ARC-0600 Pharma Grade API
    Product Series ARC-Series
    Model Number ARC-0600
    Product Type Maglev Pump
    Grade Pharma Grade API
    Technology Magnetic Levitation
    Dosage Form Compatibility Tablet, Capsule, Granule, Injection
    Route Of Administration Oral, Injectable
    Primary Application Pharmaceutical manufacturing for oral and injectable dosage forms
    Material Of Construction Pharmaceutical-grade stainless steel and inert polymers
    Sterilization Method Autoclavable, SIP, CIP
    Industry Pharmaceutical

    As an accredited ARC-Series Maglev Pump-ARC-0600 Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Supplied as one ARC-0600 Maglev Pump per case, in a sterile, sealed, pharmaceutical-grade container for oral and injectable API handling.
    Container Loading (20′ FCL) Container Loading (20′ FCL): ARC-Series Maglev Pump ARC-0600, pharma-grade API for tablet, capsule, granule, oral and injectable formulations.
    Shipping The ARC-Series Maglev Pump-ARC-0600 Pharma Grade API is shipped in sealed, tamper-evident, pharma-compliant packaging. Temperature-controlled logistics with monitoring maintain stability for oral or injectable use. Each shipment includes batch records, CoA, MSDS, and customs documentation. Handle per label; store protected from extreme heat, freezing, and contamination.
    Storage Store ARC-0600 Pharma Grade API/Maglev Pump in a clean, dry, well-ventilated area at 15–25°C, protected from sunlight, moisture, heat, and incompatible materials. Keep original packaging tightly closed, labeled, and dust-free. Maintain controlled humidity and cGMP segregation to prevent cross-contamination. Do not freeze. Avoid impact, vibration, and corrosive vapors. Store away from ignition sources, and keep containers sealed until use. Follow manufacturer and pharmacopeial requirements.
    Shelf Life Shelf life: typically 24–36 months for sealed API stored dry at 15–30°C, protected from light; confirm via manufacturer stability data.
    Application of ARC-Series Maglev Pump-ARC-0600 Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    Direct compression of ARC-0600 Pharma Grade API into immediate-release tablet cores is implemented only after powder rheology has been confirmed on a Schulze RST-XS ring shear tester with a flow function coefficient not lower than 4.0 at 3 kPa normal stress. Incoming API particle size distribution is determined by laser diffraction according to USP <429> and ISO 13320:2020; direct compression is sensitive to fines below 10 µm, so D10 should remain above 15 µm, while D90 is typically held below 150 µm to reduce punch filming and sticking. If the relative humidity in the processing suite exceeds 60% RH, the API is pre-dried in a fluid-bed dryer at 40 °C ± 2 °C for not less than 4 h with inlet air dew point no higher than −10 °C. A representative batch is composed of 12.0 wt% ARC-0600, 84.5 wt% microcrystalline cellulose PH-102, 2.0 wt% crospovidone, 1.0 wt% colloidal silicon dioxide, and 0.5 wt% magnesium stearate. Blending is performed in a 600 L bin blender at 15 rpm for 20 min, with magnesium stearate added only in the final 3 min to limit shear-induced hydrophobicity. Compression is carried out on a 16-station rotary tablet press fitted with B-tooling; precompression force is set at 3–5 kN, main compression force at 8–18 kN, and turret speed at 25–40 rpm. Ejection force is monitored continuously and maintained below 800 N to avoid picking and chipping. Blend uniformity is evaluated per USP <905> with Stage 1 acceptance value L1 ≤15.0; tablet hardness is measured per USP <1217>; disintegration per USP <701> in 900 mL purified water at 37 °C ± 2 °C; and dissolution per USP <711> Apparatus 2 at 50 rpm in 900 mL of 0.01 N HCl. The terminal immediate-release tablet has a target mass of 250 mg, hardness 4–8 kp, friability below 0.8% after 100 rotations per USP <1216>, and not less than 80% release in 30 min for a typical immediate-release acceptance criterion. This direct compression route is incompatible with API lots having bulk density below 0.35 g/cm³ and with formulations requiring more than 2.0 wt% sodium starch glycolate, which may promote over-drying and capping under extended precompression dwell times.

    How Does Roller Compaction Affect ARC-0600 Recompression Potential?

    Only after direct compression has been ruled out by flow function coefficient below 4.0 or by segregation tendency exceeding 5.0% RSD in full-scale hopper discharge is dry granulation by roller compaction selected for ARC-0600. A representative dry granulation formulation is 20.0 wt% ARC-0600, 73.0 wt% mannitol SD200, 5.0 wt% pregelatinized starch, and 2.0 wt% croscarmellose sodium, with an external phase of 1.0 wt% magnesium stearate added after milling. The preblend is compacted on an Alexanderwerk WP 120 roller compactor at roll force 5–15 kN/cm, roll gap 1.5–2.5 mm, roll speed 3–8 rpm, and roll surface temperature below 40 °C to avoid stickiness. Ribbon solid fraction is controlled between 0.55 and 0.70 as calculated from envelope density by helium pycnometry; ribbon porosity below 0.35 may indicate overcompaction and loss of recompression potential, while porosity above 0.45 produces weak granules that generate excessive fines. The ribbons are milled through a Comil U5 fitted with a 1.0 mm round-hole screen at impeller speed 2000–3500 rpm, yielding granule D50 between 250 µm and 500 µm by USP <786>. Granule loss on drying is controlled by USP <731> at ≤2.0%, and the final blend is tested for content uniformity by USP <905> with relative standard deviation not more than 5.0%. In-process monitoring is executed under 21 CFR 211.110. The resulting granules are filled into hard capsules or compressed into tablet cores with tensile strength not less than 1.2 MPa; ejection force in tableting should remain below 900 N. Roller compaction is incompatible with API lots having D90 above 300 µm without pre-milling, because coarse API domains persist as surface-enriched agglomerates after milling and compromise blend uniformity.

    When ARC-0600 exhibits unacceptable flow that cannot be corrected by dry granulation and is chemically stable under aqueous conditions, high-shear wet granulation delivers densified granules with improved die filling and reduced dust generation. A representative aqueous granulation formula is 25.0 wt% ARC-0600, 60.0 wt% lactose monohydrate 200M, 10.0 wt% microcrystalline cellulose PH-101, 3.0 wt% crospovidone, and 2.0 wt% povidone K30 as binder. Dry blending is performed in a 25 L high-shear granulator at impeller speed 150–300 rpm and chopper speed 1500 rpm for 3 min; purified water or a 5 wt% povidone K30 solution is sprayed at 80–150 g/min until the impeller torque rises 30–50% above the dry-mix baseline. Endpoint control is based on torque rise and wet mass visual consistency rather than a fixed water volume, because the water-binding capacity of ARC-0600 varies with particle morphology. The wet mass is dried in a GPGC-5 fluid-bed dryer with inlet air temperature 50–65 °C and product temperature not exceeding 40 °C, until loss on drying by USP <731> is 1.5–2.5%. Dried granules are milled through a 1.0 mm oscillating screen and blended with 1.0 wt% magnesium stearate for 3 min at 15 rpm. Granule particle size distribution is monitored by USP <786>; friability of the dried granules is measured by rotating 10 g of granule with 200 glass beads for 15 min at 25 rpm, and acceptable granule friability is below 15%. The terminal tablet cores are compressed to 450 mg target mass with hardness 8–12 kp, disintegration not more than 15 min by USP <701>, and immediate-release dissolution by USP <711> Apparatus 2 in 900 mL of 0.01 N HCl at 50 rpm. In-process controls are executed under 21 CFR 211.110 and production records are maintained under 21 CFR 211.186; if organic binder solvents are substituted, residual solvent levels must comply with ICH Q3C Class 2 or Class 3 limits. Aqueous granulation is not appropriate if forced degradation under ICH Q1A(R2) demonstrates more than 0.5% total degradation at 40 °C / 75% RH for 4 weeks.

    Process control pointStandard/methodAcceptance range or target
    API identity and assayUSP monograph and 21 CFR 211.84Assay 98.0–102.0% of label claim
    Blend uniformityUSP <905>Stage 1 L1 ≤15.0
    Tablet hardnessUSP <1217>4–12 kp depending on formulation
    DisintegrationUSP <701>≤15 min in purified water at 37 °C ± 2 °C
    DissolutionUSP <711>Not less than 80% at 30 min for immediate release

    Capsule Plug Formation and Low-Dose Content Uniformity

    Low-dose hard capsule filling with ARC-0600 requires a staged pre-blend to prevent segregation of the API and to achieve a compressible plug that maintains dose uniformity. A premix is prepared by blending 1 part micronized ARC-0600 with 9 parts lactose monohydrate 200M for 10 min in a 300 L bin blender at 20 rpm; this premix is then diluted with microcrystalline cellulose PH-102 to a final API concentration of 2.0 wt%, plus 2.0 wt% crospovidone, 0.5 wt% colloidal silicon dioxide, and 0.5 wt% magnesium stearate. The final blend is mixed for an additional 15 min at 15 rpm, because higher shear or longer mixing can over-lubricate the plug and reduce capsule disintegration. Encapsulation is performed on a Bosch GKF 720 dosator-type machine at 60,000 capsules/h; tamping pin stations are set to produce plug heights between 10 mm and 13 mm for size 3 hard gelatin or HPMC shells. Fill weight is monitored by in-process checkweighing every 10 min, and the average fill weight is maintained within ±3.0% of target. The shell moisture content is kept below 13% for gelatin and below 5% for HPMC to avoid brittle shell failure. Content uniformity is assessed by USP <905> with Stage 1 L1 ≤15.0; dissolution uses USP <711> Apparatus 1 at 100 rpm in 900 mL of 0.01 N HCl. In-process controls comply with 21 CFR 211.110. The resulting capsule has a total fill weight of 250 mg and a shell size of 3; dose strength is defined by the approved application and may require a lower API concentration if the blend shows electrostatic adhesion to machine surfaces. Capsule filling is not recommended when API D90 exceeds 200 µm, because coarse particles create plug porosity gradients and increase fill weight variability beyond the ±3.0% control limit.

    Injectable Solution Terminal Sterilization and Glass Container Compatibility

    For parenteral use, ARC-0600 is dissolved in Water for Injection that meets the USP monograph requirements, with pH adjusted to the approved range using 0.1 N HCl or 0.1 N NaOH; if the marketing authorization does not establish a range, pH is developed within 4.0–7.0 based on forced degradation data. A representative bulk solution at 25.0 mg/mL ARC-0600 contains 9.0 g/L sodium chloride for isotonicity and 10 mM citrate or acetate buffer if pH drift is observed; published data for ARC-0600 buffer compatibility is limited, so forced degradation under ICH Q1A(R2) should identify pH-sensitive degradation products before the batch formula is locked. The bulk solution is prefiltered through a 0.45 µm PVDF membrane and then sterile-filtered through two 0.22 µm sterilizing-grade membranes in series. If the API is thermally stable, terminal sterilization is executed at 121 °C for 15 min with a validated F0 not less than 8 min; otherwise aseptic filling is conducted in an ISO 5 environment under ISO 14644-1 classification. Finished product testing includes sterility by USP <71>, bacterial endotoxins by USP <85> with a limit derived from the maximum bolus dose, sub-visible particulate matter by USP <788> with limits of ≥10 µm ≤6000 per vial and ≥25 µm ≤600 per vial for containers of ≤100 mL, visible particulates by USP <790>, pH by USP <791>, and osmolality by USP <785> at 270–328 mOsm/kg for an isotonic presentation. The solution is filled into 10 mL Type I borosilicate glass vials under nitrogen headspace and sealed with bromobutyl rubber stoppers; glass delamination is assessed by USP <1660>. Injection formulation is incompatible with phosphate buffers if solubility studies show ARC-0600 forms insoluble phosphate salts; compatibility with chloride-containing stoppers is confirmed by extractables and leachables testing under USP <1663> and USP <1664>.

    Quality attributeStandard/methodTarget or limit for parenteral ARC-0600
    SterilityUSP <71>No growth
    Bacterial endotoxinsUSP <85>≤0.25 EU/mg or dose-specific limit
    Sub-visible particulate matterUSP <788>≥10 µm ≤6000/vial; ≥25 µm ≤600/vial for ≤100 mL
    Visible particulatesUSP <790>Practically free
    pHUSP <791>Specified range, typically 4.0–7.0
    OsmolalityUSP <785>270–328 mOsm/kg for isotonic formulation
    Residual moisture in lyophilized productUSP <921> Method Ic≤1.0%

    Lyophilization is selected when terminal sterilization of ARC-0600 solution presents unacceptable degradation risk or when the drug product requires a dry powder presentation for reconstitution. The pre-lyophilization solution is formulated with 5.0 wt% ARC-0600, 3.0 wt% mannitol, 0.5 wt% trehalose dihydrate, and Water for Injection. The solution is sterile-filtered through a 0.22 µm membrane and filled at 10 mL per 20 mL Type I glass vial. The freeze-drying cycle begins with shelf cooling to -40 °C at 1 °C/min and holding for 2 h; annealing at -10 °C for 1–2 h may be used if mannitol crystallization is required, but the annealing temperature must remain below the collapse temperature measured by freeze-dry microscopy. Primary drying is conducted at shelf temperature -25 °C and chamber pressure 75–100 mTorr for 24–36 h, with product temperature monitored by resistance thermal detectors and kept below the collapse boundary. Secondary drying raises shelf temperature to 30 °C for 4–8 h, producing residual moisture by Karl Fischer USP <921> Method Ic not more than 1.0%. Aseptic operations are controlled under 21 CFR 211.113. The lyophilized cake is evaluated for appearance, reconstitution time, sterility by USP <71>, bacterial endotoxins by USP <85>, particulate matter by USP <788>, visible particulates by USP <790>, and container closure integrity by USP <1207>. The terminal product is a lyophilized cake for reconstitution with 10 mL Sterile Water for Injection; reconstitution should yield a clear solution in ≤2 min without visible agglomerates. Collapse or meltback is rejected under visual inspection and indicates a failed lyophilization cycle; high residual moisture above 1.0% may reduce shelf-life stability and is controlled by extending secondary drying within the validated design space.

    Free Quote

    Competitive ARC-Series Maglev Pump-ARC-0600 Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    The ARC-Series Maglev Pump ARC-0600 is a sealless, magnetically levitated centrifugal pump specified for pharmaceutical active pharmaceutical ingredient transfer across tablet, capsule, granule, oral liquid, and injectable manufacturing. The pump is not a positive-displacement device; it maintains impeller position through a contact-free magnetic bearing, eliminating shaft seals, rolling-element bearings, and rubbing surfaces from the product zone. The standard wetted casing is forged 316L stainless steel with a pharmaceutical electropolish finish of Ra ≤ 0.25 µm for injectable duty and Ra ≤ 0.5 µm for oral solid dosage duty, measured by stylus profilometry in accordance with ASME BPE-2024 SD-3.4.1. A Hastelloy C-22 casing option is specified for chloride-containing process streams. The rotor magnet is encapsulated in PFA with USP <88> Class VI and ISO 10993-5:2009 cytotoxicity documentation. Nominal hydraulic performance is 0.5 L/min to 60 L/min against differential head up to 80 m, with product temperature from 5 °C to 95 °C and steam-in-place exposure at 135 °C for 30 min. The pump is supplied with EN 10204 3.1 material certificates, USP <790> particulate matter data, and USP <85> bacterial endotoxin documentation for the wetted flow path.

    ParameterConfigured specification
    ModelARC-0600 Pharma Grade API
    Pump typeSealless magnetically levitated centrifugal
    Wetted materials316L / 1.4404 electropolished; Hastelloy C-22 option; PFA-encapsulated rotor magnet
    Wetted surface finish0.25 µm Ra injectable; 0.5 µm Ra oral solid dosage
    Rated flow0.5 L/min – 60 L/min
    Differential headUp to 80 m at 1,500 rpm to 3,600 rpm
    Process temperature5 °C – 95 °C
    SIP temperature135 °C for 30 min
    Viscosity limit≤ 500 mPa·s at nominal speed
    Maximum suspended particle size≤ 1.5 mm non-abrasive; hard abrasive slurries excluded
    Regulatory documentationUSP <88> Class VI, USP <85>, USP <788>, USP <790>, ISO 10993-5:2009, ASME BPE-2024, EN 10204 3.1

    What Particle and Endotoxin Limits Constrain ARC-0600 Transfer of Injectable API Solutions?

    Transfer of injectable-grade API solutions requires that the pump contribute no measurable particulate burden above the finished-product limits defined in USP <788>. In light-obscuration testing, large-volume parenterals must meet ≤ 25 particles per mL ≥ 10 µm and ≤ 3 particles per mL ≥ 25 µm; the ARC-0600 wetted path is supplied with cleanroom-assembled certification demonstrating particle counts below the USP <790> visible-particulate threshold when flushed with filtered water for injection. Because the impeller is levitated without mechanical bearings, no metal-to-metal wear occurs in the product zone. A rotary lobe pump with a double mechanical seal, by comparison, generates seal face wear debris and requires seal barrier fluid management; a peristaltic pump sheds elastomer fragments from tube fatigue. The ARC-0600 uses no flexible tube and no shaft seal, which simplifies extractables profiling under USP <665> for polymer processing components and reduces the number of materials requiring USP <88> Class VI testing. For water-thin injectable API solutions with viscosity 1–10 mPa·s, the pump is typically operated with a 0.2 µm sterilizing-grade filter downstream; minimal shear and absence of mechanical seal wear reduce the risk of filter fouling. Published data for this specific configuration is limited in peer-reviewed literature; the validation package therefore includes supplier batch records and water flush particulate recovery rather than a cross-manufacturer study.

    Cleaning Validation and Sterilization-in-Place Boundary Conditions

    The ARC-0600 is compatible with clean-in-place sequences when the casing is installed without dead legs and with drainage geometry meeting ASME BPE-2024 SD-3.5. A typical CIP sequence uses 1 % sodium hydroxide at 80 °C for 20 min, followed by 1 % phosphoric acid at 70 °C for 10 min, and final water-for-injection rinse until conductivity returns to ≤ 1.3 µS/cm at 25 °C. The CIP supply velocity at the casing wall must exceed 1.5 m/s to achieve riboflavin removal within 10 min. Steam-in-place is performed at 135 °C for 30 min with condensate drainage verified by thermocouple mapping; the magnetic bearing controller must remain powered to prevent rotor touchdown during thermal expansion. The pump is not rated for dry-running beyond 30 s. Product viscosity above 500 mPa·s requires reduced speed or a positive-displacement alternative; the ARC-0600 is not suitable for high-solids granule paste exceeding 25 % w/w solids. Suspensions with particle hardness above Mohs 5 are excluded from the standard wetted path.

    Oral solid dosage transfer of tablet and capsule granulations is typically performed with a 1,000 L high-shear granulator discharge vessel, a 50 mm transfer line, and a downstream fluid-bed dryer. The ARC-0600 is installed at the discharge of the granulator bowl to move wet granulate at solids content up to 20 % w/w without the pulsation-induced segregation common to diaphragm pumps. Because the impeller clearance and low tip speed reduce droplet shear, the pump does not require a separate shear-sensitive bypass for coated multiparticulates. The wetted surface roughness of 0.5 µm Ra prevents product holdup and reduces cross-batch contamination risk. At 2,500 rpm, the pump delivers approximately 25 L/min against 35 m head, depending on viscosity. The same pump body can be reassigned to injectable service only after complete casing exchange and re-cleaning, not by using the oral solid dosage wetted path without modification.

    When Tablet Granule Suspensions and Aqueous Injectable Solutions Share a Transfer Pump Platform

    Single-pump platform use across oral and injectable applications is permitted only after dedicated product-contact parts are assigned per dosage form. The injectable flow path uses 0.25 µm Ra electropolished casings and PFA-encapsulated rotor magnets, while the oral solid dosage path may use 0.5 µm Ra surfaces. The ARC-0600 is supplied with a detachable casing that allows exchange without rebalancing the rotor; the magnetic bearing controller recalibrates position at each start-up. This feature differs from lobe pumps, which require mechanical seal replacement and re-lapping after product contact, and from peristaltic pumps, which require tube replacement after 50–100 h of continuous operation. The absence of a mechanical seal removes a leak path for potent compounds, reducing operator exposure risk. Containment options include a double-walled casing with leak detection port and a bellows isolation variant for compounds with OEL ≤ 1 µg/m³.

    Pump typePrimary wear itemParticulate shedding riskPulsation characterMaintenance interval
    ARC-0600 maglev centrifugalNone in product zone; rotor levitatedBelow USP <788> limits after flushContinuous centrifugal discharge; ≤ 2 % flow pulsation at rated speedBearing controller check after 8,000 h
    Rotary lobeMechanical shaft seal, timing gearsSeal face wear debris; requires barrier fluidLobe pulse; 5–10 % flow pulsationSeal replacement after 2,000 h
    PeristalticFlexible tubeElastomer spallationHigh pulsation; requires pulse dampenerTube replacement after 50–100 h
    Air-operated double diaphragmDiaphragm plates, check ballsDiaphragm material lossStrong pressure pulses; requires surge suppressorDiaphragm replacement after 1,500 h

    Operational boundaries are explicit: the ARC-0600 is not intended for continuous dry running, hard abrasive slurries, or product viscosity above 500 mPa·s. It should not be used with solvents that plasticize PFA beyond 10 % weight gain in 24 h at process temperature. The magnetic bearing controller requires a stable 24 V DC supply and clean dry air purge of 0.2 bar for condensation protection when installed in cold rooms. The pump is not certified for explosion-proof environments unless the optional ATEX II 2G Ex db IIB T4 motor is specified. Published data for this specific configuration is limited for live-virus and live-attenuated vaccine intermediates; end-users should perform process-specific particulate and endotoxin qualification before introduction into aseptic manufacturing.

    Top