Products

Apixaban intermediate Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    • Product Name: Apixaban intermediate Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales10@sinochem-nanjing.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    VTB
    Specifications
    HS Code 362631
    Product Name Apixaban Intermediate Pharma Grade API
    Cas Number 503612-47-3
    Molecular Formula C25H25N5O4
    Molecular Weight 459.5 g/mol
    Grade Pharma Grade / API Grade
    Purity ≥99.0% (HPLC)
    Appearance White to off-white crystalline powder
    Solubility Practically insoluble in water; soluble in DMSO and methanol
    Storage Conditions Store in a cool, dry place, protected from light and moisture
    Shelf Life 24 to 36 months
    Dosage Forms Tablet, Capsule, Granule, Injection
    Route Of Administration Oral and Injectable
    Therapeutic Category Anticoagulant / Factor Xa Inhibitor
    Standard USP / EP / BP / In-house
    Packaging 25 kg fiber drum with double polyethylene liner

    As an accredited Apixaban intermediate Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packed in 25 kg net double polyethylene-lined fiber drums, securely sealed for pharmaceutical-grade Apixaban intermediate API storage and transport.
    Container Loading (20′ FCL) 20′ FCL container loading: palletized, sealed Apixaban intermediate Pharma Grade API drums, stowed dry, clean, and secure for oral/injectable formulations.
    Shipping Shipping Description: Apixaban intermediate Pharma Grade API is transported in sealed, tamper-evident, moisture-barrier containers under controlled temperature, protected from light and contamination. Qualified couriers handle distribution with COA, MSDS, packing list, and customs documentation. Cold-chain or ambient conditions apply per stability requirements for oral and injectable use.
    Storage Store Apixaban intermediate Pharma Grade API in tightly closed, labeled containers in a cool, dry, well-ventilated area at controlled room temperature (15–25°C), protected from light, moisture, heat, and contamination. Keep away from incompatible materials. Maintain cGMP-compliant, segregated storage with controlled access, pest control, and inventory/retest tracking. Keep containers sealed until use; avoid contact with food, feed, or drinking water.
    Shelf Life Shelf life is typically 24–36 months when stored sealed, dry, protected from light, at controlled room temperature, per supplier stability data.
    Application of Apixaban intermediate Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable

    When 2.5 mg and 5 mg dose strengths are processed by direct compression, the milled apixaban intermediate is first geometrically pre-blended with a lactose monohydrate carrier and microcrystalline cellulose. The purpose of this step is not only to satisfy USP <905> uniformity criteria but also to prevent segregation of a low-dose active with a D90 below 20 µm. A 600 L bin blender filled to 60% of gross volume and operated at 12 rpm typically reaches an in-process assay RSD below 5.0% after 15–20 min for a 1–3% w/w active premix. Production-scale lines encounter two competing constraints. Micronized intermediate improves dissolution but reduces bulk flow; a flow function coefficient below 2.0 can produce weight variability and sticking on 9 mm round tooling. Fumed silica at 0.25–0.5 wt% of the total blend mass is introduced to raise the flow function coefficient above 4.0 without retarding release. Magnesium stearate is limited to 0.5–1.0 wt% and total final blending time to 3–5 min; over-lubrication creates a hydrophobic film that delays dissolution and lowers tablet tensile strength. Compression on a rotary press at 15–25 kN yields tablets with tensile strength above 1.5 MPa and friability below 0.8% when measured by USP <1216>. Dissolution is assessed by USP <711>; for immediate-release cores, release above 80% within 30 min is a routine development target in surfactant-containing media. Segregation during hopper transfer remains the main batch-to-batch defect: press speed is limited to 60–80 tablets/min when the blend contains more than 15% fines below 150 µm. If direct compression is not viable, the same intermediate is re-routed to dry granulation.

    Dosage form critical process controls and associated compendial methods
    Dosage formCritical controlMethodTypical industrial target
    TabletBlend uniformityUSP <905>RSD ≤ 5.0%
    CapsuleContent uniformityUSP <905>RSD ≤ 4.0%
    GranuleResidual moistureUSP <921>LOD ≤ 2.0%
    InjectionSubvisible particulate matterUSP <788>≤ 6000 particles/container at ≥10 µm
    InjectionBacterial endotoxinUSP <85>Product-specific limit per kg/h dosing

    Can Low-Fill-Weight Hard Capsules Maintain Content Uniformity Without Over-Lubrication?

    Capsule filling of a 2.5 mg apixaban intermediate blend presents a different failure mode than tablet compression. The target fill weight for a size 3 hard capsule is often below 150 mg; at this scale, a tamping pin filler requires a powder bed with Carr index below 25 and Hausner ratio below 1.25. Without these flow properties, fill weight RSD exceeds 4.0% and content uniformity testing under USP <905> becomes the primary release risk. The intermediate is pre-dispersed in a dry blend of lactose monohydrate, microcrystalline cellulose, and croscarmellose sodium. Sodium stearyl fumarate at 0.5–1.0 wt% is used in place of magnesium stearate when dissolution lag is observed; the former generates less hydrophobic surface coverage on the active. Hard gelatin shells equilibrated at 13–15% moisture transfer water into a dry fill blend and can initiate sticking inside the dosing chamber. HPMC shells at 4–6% moisture offer lower water activity and are better matched to amide-containing actives. Disintegration is verified by USP <701> at 37 ± 2 °C; immediate-release capsules in development are expected to disintegrate within 15 min in aqueous media. Dissolution using USP <711> apparatus II at 50 rpm in 900 mL surfactant-containing medium is run on 12 units; a release plateau below 80% at 30 min typically traces back to over-blending with magnesium stearate or excessive tamping pin pressure. Production-scale capsule fillers with 150,000 capsules/hour capacity must be validated for pin lubrication and dust extraction; dust generation from low-fill-weight blends without adequate fines control can shift fill weight drift by more than 3% across an 8-hour batch. Capsule shell moisture and fill blend water activity are logged at line start, mid-batch, and end-batch to control shell brittleness and cross-linking potential.

    Granule Flow and Residual Moisture Boundaries for Sachet and Sprinkle Formats

    High-shear wet granulation introduces a moisture-driven degradation threshold that is not present in direct compression or roller compaction. Apixaban intermediate contains amide linkages; exposure to water at 40–60 °C during wet massing can increase hydrolysis-related impurities if drying is delayed. The granulating fluid is therefore formulated as a 15–25% w/w aqueous binder solution added over 3–5 min at rotor speed 200–400 rpm, or as an isopropanol-water mixture to reduce water activity. Wet mass is discharged through a 1.0 mm screen and dried in a fluid bed at inlet air 50–60 °C until loss on drying is below 2.0% by USP <921> Karl Fischer or LOD method. Final granules are screened to retain a 180–850 µm fraction with D50 between 250 µm and 400 µm. Fines below 150 µm increase segregation risk in form-fill-seal sachet filling; oversized material above 850 µm causes incomplete dispersion when the dose is sprinkled into water or soft food. The granule flow function coefficient should exceed 4.0 before a vertical sachet filling line can hold weight variation below 5% RSD. A dispersion test in 50 mL water at 25 °C is used to reject granule batches that retain agglomerates; the suspension is passed through a 500 µm sieve and visually inspected for undispersed particles. Published data for a specific apixaban sachet formulation are limited; the above thresholds derive from general scale-up data for low-dose poorly soluble anticoagulant granulations. If the sachet format includes a desiccant pouch, the granule moisture specification may need to be tightened below 1.5% to offset moisture ingress through laminate edges. Stability under 40 °C/75% RH conditions per ICH Q1A is used to define the final blend packaging configuration.

    Because a sterile injectable presentation of apixaban intermediate has no monograph-recognized formulation, development begins with a solubility screen rather than a fixed manufacturing route. Published data specific to apixaban injectable solutions are limited. The neutral amide core can require pH adjustment, co-solvents such as propylene glycol and polyethylene glycol 300 at 20–40% total organic content, or complexation with a cyclodextrin to reach a therapeutically relevant concentration. Co-solvent levels above 40% create pain on injection and raise osmolality above 320 mOsm/kg; the target isotonic range is 280–320 mOsm/kg. Terminal sterilization at 121 °C for 15 min may stress amide-containing APIs. Degradation pathways must be mapped before a terminal sterilization cycle is selected; otherwise, aseptic filtration through a 0.22 µm PVDF membrane with a validated bubble point test is used. Fill volume for a single-dose injection typically ranges from 1 mL to 10 mL. Subvisible particulate matter is controlled by USP <788>; for small-volume injections, the light obscuration method limits are not more than 6000 particles per container at ≥10 µm and not more than 600 particles per container at ≥25 µm. Visible particulates are controlled by USP <790> under inspection lighting. Bacterial endotoxin testing by USP <85> uses a product-specific limit calculated from the maximum bolus dose in mL/kg and the endotoxin limit of 5 USP EU/kg per hour for intravenous administration, not from a universal input value for the raw API. Sterile filling is executed in an ISO 14644-1 Class 5 environment with unidirectional airflow and a restricted-access barrier system or isolator. If solution stability data show unacceptable impurity growth after 24 h at 25 °C, lyophilization is evaluated; the glass transition temperature of the frozen matrix is not predicted from the API alone, so collapse temperature is measured by freeze-drying microscopy before cycle design. No injection route should be locked without spike-and-recovery data for the filter membrane and compatibility data for silicone tubing and elastomeric closures.

    Roller compaction offers a dry granulation route for apixaban intermediate when direct compression blends fail flow function criteria or when a higher drug load is targeted in a fixed-dose combination. Ribbon density is controlled between 1.1 g/cm³ and 1.3 g/cm³ by adjusting hydraulic roll pressure from 30 kN to 60 kN at roll speed 5–15 rpm. Milling through a 0.8–1.0 mm screen produces granules with D50 between 200 µm and 400 µm. The dominant failure mode is fines generation: if granules below 150 µm exceed 30% of the batch, segregation during bin transfer and compression hopper hold-up causes content uniformity drift exceeding 5% RSD. In that event, the granulation is re-screened and blended with 0.25 wt% colloidal silicon dioxide before the final lubrication step. The granule flow function coefficient after roller compaction typically increases from below 2.0 to above 4.5, enabling rotary press speeds of 60–80 tablets/min for 9 mm round tooling without weight variation beyond 3% RSD. Post-granulation mixing with magnesium stearate is limited to 3–5 min; longer times redistribute hydrophobic lubricant onto granule surfaces and depress early dissolution. Ribbon density variability across the roller width is measured at the left, center, and right positions because edge leakage produces low-density ribbon that mills into excess fines. If ribbon density drops below 1.0 g/cm³, the roll side seals must be inspected for wear and the feeding screw speed adjusted to maintain a stable nip angle. Dissolution is tested by USP <711>; any release plateau shift after 4 weeks at 40 °C/75% RH should trigger a review of the lubricant level and granule porosity rather than automatic reformulation.

    What Changes When an Immediate-Release Film Coat Is Applied to Low-Dose Cores?

    Film coating of apixaban immediate-release cores introduces heat and moisture stress that can shift dissolution and mechanical integrity. A 24-inch side-vented pan with pan speed 6–12 rpm, inlet air 60–70 °C, exhaust 40–50 °C, and spray rate 8–15 g/min applies an aqueous Opadry II dispersion at 10–12% solids to a 2–4% weight gain. If the core contains croscarmellose sodium, water uptake during the first coating phase can induce swelling and edge chipping; lowering the spray rate and raising inlet air temperature reduces moisture penetration into the core. Hardness should not fall below 1.5 MPa and friability should remain below 0.8% after 2–4% coating weight gain. Dissolution is retested by USP <711> because excessive coating weight or uneven pan distribution can create a release-lag artifact that is unrelated to the API. Coating pan load size is selected to keep tablet bed surface speed constant; a batch that fills 60–70% of pan volume is used for reproducible mixing, while lower fill levels can result in spray drying and higher fill levels can cause tablet breakage at the bed surface. Core preheating is monitored with an infrared sensor; exhaust temperature above 50 °C for more than 10 min can overdry the core and increase friability. Final visual inspection under USP <790> lighting conditions is used to reject coated tablets with film peeling, color nonuniformity, or edge exposure. Coating suspension preparation must follow a validated hold time because Opadry II dispersions beyond 12 h can undergo viscosity drift and deliver variable spray droplet size. Final release testing under FDA 21 CFR 211.165 links the coating step back to core uniformity, dissolution, and impurity data before the batch is dispositioned.

    Free Quote

    Competitive Apixaban intermediate Pharma Grade API for Tablet / Capsule / Granule / Injection, Oral & Injectable prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@sinochem-nanjing.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@sinochem-nanjing.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Apixaban intermediate Pharma Grade API, model code APIX-PH-459, is supplied as a white to off-white crystalline powder for downstream tablet, capsule, granule, and injectable dosage-form manufacturing. The chemical identity is confirmed against CAS 503612-47-3, molecular formula C25H25N5O4, and molecular weight 459.50 g/mol. The IUPAC name is 1-(4-methoxyphenyl)-7-oxo-6-[4-(2-oxopiperidin-1-yl)phenyl]-4,5,6,7-tetrahydro-1H-pyrazolo[3,4-c]pyridine-3-carboxamide. The product is distinguished from technical-grade apixaban base by controlled residual solvent, elemental impurity, particle size distribution, and endotoxin profiles aligned with USP/NF and Ph. Eur. methods. The term intermediate Pharma Grade API denotes a single-entity active ingredient with formulation-specific physical attributes, not a milled technical powder. The oral solid grade is coded APIX-PH-459, while the injectable grade is coded APIX-INJ-459. These model codes are vendor-specific and are cross-referenced to the same CAS number on each certificate of analysis.

    Primary packaging is an HDPE drum with double LDPE liner in 1 kg, 5 kg, and 25 kg net weights. Storage under 15–25 °C and ≤40% RH in original sealed containers is specified; the retest interval is assigned from ICH Q1A(R2) stability data. The crystalline form should be verified by XRPD using USP <941> because different recrystallization solvents can produce different apixaban crystalline phases. Solubility is pH-dependent and limited in aqueous media; dissolution development for tablets and capsules uses USP <711> with surfactant or pH-shift media rather than a single compendial sink condition. No interchange between crystallization lots is permitted without comparative XRPD, DSC, and residual solvent review. The powder is not micronized for standard oral grades; if colloidal or nano formulations are required, a separate micronized grade with D90 ≤10 µm and nitrogen-adsorption surface area control should be used. Such grades are not interchangeable with the standard oral solid grade without dissolution and bioequivalence-driven justification.

    For oral solid-dose processing, the controlling variables are flow, compressibility, and moisture. Representative oral-grade specification windows are assay 98.0–102.0% on an anhydrous, solvent-free basis by HPLC USP <621>, total related substances ≤0.50%, water content ≤0.50% by Karl Fischer USP <921>, and residue on ignition ≤0.10% by USP <281>. These values are vendor-specific and must be confirmed against the filed dossier and certificate of analysis. Direct compression is restricted when particle size distribution yields angle of repose above 35° and Hausner ratio above 1.25. In such cases dry granulation, wet granulation, or co-processing with flow aids is required.

    What Limits Direct Compression of Apixaban Intermediate in High-Speed Tablet Presses?

    Direct compression failures in high-speed rotary presses have been traced to cohesive fines, low bulk density, and poor flow from the feed shoe into die bores. A rotary tablet press with paddle force feeder and 10 mm round tooling is typically used to detect early scale-up issues. USP <1174> and Ph. Eur. 2.9.36 powder flow tests provide preliminary screening, but the ring shear test is more predictive because it yields a flow function coefficient. Bulk density below 0.30 g/cm³ and cohesive fines can cause arching in the hopper; excessively high unconfined yield strength can create stagnant zones in the force feeder. When the flow function coefficient falls below 4, the bulk material is classified as cohesive and requires force feeder adjustments or granulation.

    A representative dry granulation route with roller compactor at compaction force 8–12 kN/cm and screen milling 1.0–1.5 mm increases D50 from 20–30 µm to 120–180 µm and reduces Hausner ratio from 1.40 to 1.20. During compression, ejection stress and precompression force are recorded at 8–18 kN main compression force and 30–80 rpm turret speed. If loss on drying exceeds 0.50% w/w, sticking to punch faces increases, particularly with magnesium stearate levels above 0.75% w/w. Tablet hardness, friability per USP <1216>, and disintegration per USP <701> are monitored because overgranulation can slow dissolution.

    For capsule filling, dosator and tamping-pin fillers are used. A D90 above 200 µm can produce fill weight variability in low-fill-weight capsules; a D10 below 10 µm can cause dusting and tamping-pin buildup. The intermediate is preblended with lactose monohydrate or microcrystalline cellulose before encapsulation to achieve fill weight uniformity per USP <905>. Granule processing in high-shear granulation with impeller speed 200–400 rpm and chopper speed 1500–3000 rpm is used for moisture-tolerant formulations; post-dry LOD is adjusted to 1.0–2.0% w/w to balance tablet hardness and dissolution. Overgranulation can extend disintegration time and slow dissolution; undergranulation can produce friable tablets. Dry granulation is preferred when the API is moisture-sensitive; the roller compaction parameters are adjusted to avoid excessive amorphous content.

    Comparative processing requirements for apixaban intermediate across dosage forms
    Dosage formCritical intermediate attributesTypical equipment or methodObserved failure mode
    Tablet by direct compressionHausner ratio <1.25, angle of repose <35°, LOD ≤0.50% w/wRotary press, 10 mm tooling, 8–18 kN compression forceWeight variability, sticking, capping
    Tablet by dry granulationRibbon density, post-mill D50 120–180 µmRoller compactor 8–12 kN/cm, screen mill 1.0–1.5 mmOvergranulation, dissolution slowdown
    CapsuleD90 <200 µm, D10 >10 µmDosator or tamping-pin filler, 0.5–10 mg fill weightFill weight variability, dusting
    GranulePost-dry LOD 1.0–2.0% w/wHigh-shear granulator 200–400 rpm impeller, fluid-bed dryerFriability, disintegration delay
    InjectableEndotoxin, bioburden, filterabilitySterile filter 0.2 µm, USP <788>Filter plugging, endotoxin failure

    Injectable-Grade Purification Reduces Endotoxin Load Below Pharmacopoeial Thresholds

    Commercial oral solid grades cannot automatically support an injectable manufacturing train. Injectable-grade apixaban intermediate is processed under controlled bioburden conditions and tested for bacterial endotoxins using USP <85>. The acceptance limit is derived from the maximum dose to be administered per kilogram; a typical intermediate control is <0.5 EU/mg, but the final limit is calculated from the formula K/M where K = 5 EU/kg and M is the maximum dose per kilogram per hour. Bioburden is controlled to <10 CFU/g by USP <61>/<62>. Subvisible particulate matter after reconstitution is assessed by light obscuration per USP <788>, with limits of 6000 particles per container at ≥10 µm and 600 particles per container at ≥25 µm. The injectable grade is usually sterile-filtered through a 0.2 µm sterilizing-grade filter; therefore the particle size distribution and specific surface area must be controlled to avoid filter plugging and viscosity rise.

    If the injection is a suspension, particle size control by laser diffraction USP <429> with D90 ≤20 µm is common; for a solution, particle size is less critical than filterability and clarity. Endotoxin measurement by the Limulus amebocyte lysate kinetic chromogenic method includes inhibition and enhancement testing because trace solvents in the intermediate can interfere with the assay. Sterile filtration for injectable manufacturing uses polyvinylidene fluoride or polyethersulfone membrane filters. For lyophilized injection, the intermediate is dissolved with pH adjustment; residual solvent composition can affect cake morphology and reconstitution time. The injectable grade may be lyophilized as a low-bioburden powder; sterility is achieved via terminal sterilization or aseptic processing under 21 CFR 211.67 equipment cleaning and 21 CFR 211.42 facility design controls. Visible particles are confirmed absent per USP <790>.

    Residual Solvent and Elemental Impurity Risk Profiles

    Apixaban intermediates from different synthetic routes may retain Class 2 solvents or heavy metals. The product is controlled under ICH Q3C and USP <467>; the certificate of analysis lists each residual solvent with limits applied according to its class. Class 2 solvent limits from ICH Q3C for common process solvents include dichloromethane 600 ppm, methanol 3000 ppm, and N,N-dimethylformamide 880 ppm. These values are applied unless a daily exposure calculation supports a different limit in the finished product. For injectable processing, the same limits may be tighter when the route of administration changes. Headspace gas chromatography with flame ionization detection is used because the intermediate is nonvolatile and can be dissolved directly in dimethyl sulfoxide. Elemental impurities are controlled under ICH Q3D and USP <232>/<233>. Because synthesis can involve transition-metal catalysis, batch-specific data for palladium, copper, zinc, and iron are required. The permitted daily exposure for the parenteral route can be lower than the oral route by a factor dependent on bioavailability and duration of use; no single acceptance table applies to all dosage forms.

    Representative vendor-specific specification windows for apixaban intermediate oral and injectable grades
    AttributeAnalytical procedureOral solid grade APIX-PH-459Injectable grade APIX-INJ-459
    Assay (anhydrous, solvent-free)HPLC USP <621>98.0–102.0%98.0–102.0%
    Total related substancesHPLC USP <621>≤0.50%≤0.30%
    Water contentKarl Fischer USP <921>≤0.50% w/w≤0.30% w/w
    Residue on ignitionUSP <281>≤0.10%≤0.10%
    Elemental impuritiesUSP <232>/<233>, ICH Q3DOral PDEParenteral PDE
    Bacterial endotoxinsUSP <85>Not specified<0.5 EU/mg
    BioburdenUSP <61>/<62><100 CFU/g<10 CFU/g
    Particle size D90Laser diffraction USP <429>≤150 µm≤20 µm (suspension)

    The tabulated values are representative vendor-specific windows and are not a substitute for the filed specification or the certificate of analysis for a given batch.

    When a Tablet Grade Is Rejected for Injectable Compounding

    The oral solid grade cannot be diverted into an injectable batch solely on the basis of assay and chromatographic purity. Injectable manufacturing requires bacterial endotoxin testing per USP <85>, bioburden per USP <61>/<62>, and subvisible particulate matter per USP <788>. The oral grade may contain endotoxin above 0.5 EU/mg or may have a particle size and surface area that blocks sterilizing-grade filters. If the intermediate is lyophilized, cake appearance and reconstitution time are affected by specific surface area and residual solvent level. No interchange should occur without a cross-contamination and endotoxin risk assessment under 21 CFR 211.42 and 21 CFR 211.67.

    Compared with rivaroxaban and edoxaban, apixaban intermediate is handled as the free base, with no salt formation. Rivaroxaban has a molecular weight of 435.88 g/mol and an oxazolidinone scaffold; edoxaban tosylate has a molecular weight of 548.06 g/mol as the salt. The pyrazolopiperidinone structure of apixaban changes crystal habit, tabletability, and chromatographic impurity profiles. These structural differences require different HPLC columns, mobile phases, and dissolution media. Apixaban is used at lower unit dose strengths such as 2.5 mg and 5 mg, which increases the effect of fill weight variability and content uniformity. The apixaban intermediate should not be substituted into a rivaroxaban or edoxaban formulation train without full revalidation under ICH Q2(R1).

    Batch-to-batch variance in recrystallization solvent composition can affect crystal habit and downstream compaction; the certificate of analysis should state the final recrystallization solvent and polymorphic form. Published data for this specific configuration is limited.

    Top