Tetraacetylethylenediamine

Tetraacetylethylenediamine

    VTB
    Specifications
    HS Code 986680
    Productname Tetraacetylethylenediamine
    Iupacname N,N,N',N'-tetraacetylethane-1,2-diamine
    Casnumber 10543-57-4
    Ecnumber 234-123-8
    Molecularformula C10H16N2O4
    Molecularweight 228.25 g/mol
    Appearance White to off-white crystalline powder or granules
    Odor Odorless to slight acetic odor
    Meltingpoint 149-152 °C
    Boilingpoint Decomposes before boiling at normal pressure
    Density 1.2-1.3 g/cm³ (relative density)
    Bulkdensity 0.6-0.8 g/cm³ (granular)
    Watersolubility Slightly soluble in water at room temperature
    Ph 6-8 (1% aqueous suspension)
    Flashpoint > 200 °C
    Decompositiontemperature > 200 °C
    Vaporpressure Very low; < 0.01 Pa at 20 °C
    Assay ≥ 98%
    Moisturecontent ≤ 0.5%

    As an accredited Tetraacetylethylenediamine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Tetraacetylethylenediamine is supplied in 25 kg net weight multi-wall paper bags with inner polyethylene liners, palletized for transport.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Tetraacetylethylenediamine chemical loaded into a 20-foot FCL container, palletized in sealed bags, and secured for safe ocean transport.
    Shipping Tetraacetylethylenediamine is generally shipped as a non-DG, non-hazardous solid in sealed, moisture-resistant bags or drums. Store and transport cool, dry, ventilated, away from oxidizers, acids, moisture, and ignition sources. Label containers clearly, use compatible packaging, and follow local regulations, SDS, and combustible-dust precautions.
    Storage Store tetraacetylethylenediamine in a cool, dry, well-ventilated area away from heat, ignition sources, and direct sunlight. Keep containers tightly closed and protected from moisture. Segregate from strong oxidizers, acids, and bases. Avoid dust generation and maintain good housekeeping. Use labeled, compatible containers. Do not store near food, drink, or animal feed. Follow local regulations and safety data sheet requirements.
    Shelf Life Tetraacetylethylenediamine is stable for several years when stored dry, cool, sealed, and protected from moisture, heat, and incompatible chemicals.
    Application of Tetraacetylethylenediamine

    What Molar Ratio Controls Peracetic Acid Generation in Low-Temperature Laundry Powders?

    In heavy-duty laundry detergent powders and tablets, tetraacetylethylenediamine (TAED) is incorporated at 1–6 wt% as a bleach activator for sodium percarbonate or sodium perborate monohydrate, and the perhydrolysis stoichiometry requires 2 mol hydrogen peroxide per 1 mol TAED to release 2 mol peracetic acid with 1 mol N,N′-diacetylethylenediamine as the residual amine. Formulators typically set the sodium percarbonate level at 10–25 wt% so that hydrogen peroxide is in molar excess over TAED, because the competing alkaline hydrolysis of TAED to acetate and N,N′-diacetylethylenediamine becomes significant when the wash-liquor pH exceeds 11.5. The granules are dry-blended into post-spray base powder or compacted in tablet form; segregation between TAED granules and larger percarbonate agglomerates is controlled by matching the sieve cut to 200–800 µm and by using a continuous ploughshare mixer with a chopper speed below 1,500 rpm to avoid attrition. Under IEC 60456:2010 washing-machine test conditions, cotton swatches stained with EMPA 101, EMPA 114, and EMPA 116 are used to evaluate low-temperature bleach activity at 20–40°C; the TAED-perborate system shifts the effective bleaching window downward from conventional hydrogen peroxide bleaches that require above 60°C. The terminal product is a wash liquor containing peracetic acid in the 10–80 mg/L range, depending on TAED loading and wash temperature. TAED-containing detergent powders should be stored below 60% relative humidity, because free moisture above 2 wt% in the finished powder can initiate pre-release of peracetic acid during storage, and TAED should not be dry-blended with strongly acidic additives that would promote premature acetylation transfer.

    Automatic dishwashing tablets expose TAED to a more concentrated alkaline wash solution than laundry, with main-wash pH typically 10.0–11.5 and temperatures of 45–65°C in programmes tested under IEC 60436:2015. TAED loading of 2–5 wt% in tablet cores, combined with 10–20 wt% sodium percarbonate and 20–40 wt% sodium disilicate or sodium citrate builders, generates peracetic acid in the wash liquor at the point where bleachable tea, coffee, and polyphenolic residues have softened but not yet redeposited on glass and stainless steel. Multi-layer and core-in-shell tablet presses operating at compaction forces between 15 and 50 kN separate TAED from hygroscopic percarbonate or acidic rinse-aid cores, because direct contact with free moisture at the granule interface initiates premature effervescence. If TAED granules are milled below 100 µm, dust formation increases and the perhydrolysis reaction in the main-wash peak can release peracetic acid as a burst that is partly lost before the soil has been fully wetted; if the granules exceed 1,000 µm, dissolution may be incomplete during the 15–30 min main-wash cycle. The terminal product is a tablet that delivers peracetic acid in the range 50–200 mg/L in the main-wash liquor, depending on water hardness and programme duration.

    Process segmentTAED loadingPeroxide sourceWorking pHTemperature
    Laundry powder1–6 wt%Sodium percarbonate 10–25 wt%9.5–11.020–60°C
    Automatic dishwashing2–5 wt%Sodium percarbonate 10–20 wt%10.0–11.545–65°C
    Pulp brightening0.5–2.0 wt% on oven-dried pulpH2O2 2–4 wt% on o.d. pulp10.5–11.570–90°C
    Textile pad-batch bleaching1–2 g/LH2O2 10–20 g/L as 50% active11–1225–30°C

    Hard-Surface Disinfection Compliance and Precursor Loading under EU BPR

    The biocidal use of in situ generated peracetic acid from TAED in hard-surface disinfectants is regulated under EU Biocidal Products Regulation No 528/2012, where the generated peracetic acid is considered the active substance released from the TAED precursor. A typical ready-to-use disinfectant solution is prepared by dissolving a powder or tablet containing TAED and sodium percarbonate in water at 20–40°C to yield peracetic acid at 100–500 mg/L at pH 7.0–9.5; the solution then acts on pre-cleaned surfaces over a contact time of 5–15 min. Bactericidal activity is tested according to EN 1276:2019 under dirty conditions containing 0.3 g/L bovine albumin, and yeasticidal/fungicidal activity according to EN 1650:2019; sporicidal claims require EN 13704:2019 with additional contact-time validation. Because the TAED-percarbonate system is alkaline during the first dissolution phase, dosing equipment with backflow prevention and corrosion-resistant stainless steel or PVDF wetted parts is specified; prolonged contact with aluminium, brass, or galvanised surfaces can produce alkaline corrosion before the peracetic acid concentration has reached the target. The operational boundary is that TAED dissolution below 20°C is incomplete, and water hardness above 350 mg/L as calcium carbonate can precipitate bicarbonate salts that depress peracetic acid yield. The terminal product is a ready-to-use disinfectant solution that must be consumed within 8 h after mixing because peracetic acid generated in situ decomposes with a half-life that shortens as pH rises above 9.5. Published data for TAED-specific half-life values in this exact ready-to-use configuration is limited.

    When TAED Is Evaluated in Hydrogen Peroxide Brightening of Mechanical Pulp

    When TAED is evaluated as an activator for alkaline hydrogen peroxide brightening of mechanical pulp, the objective shifts from detergency to the oxidation of chromophoric lignin fragments and the controlled removal of carbonyl groups that cause brightness reversion. In a medium-consistency brightening or deinking line at 10–12% stock consistency, TAED is added at 0.5–2.0 wt% on oven-dried pulp with 2–4 wt% hydrogen peroxide, sodium hydroxide, and sodium silicate at pH 10.5–11.5. Retention times of 60–120 min at 70–90°C permit in situ peracetic acid to attack quinoid structures and residual extractives without storing stabilised peracetic acid at the mill. Brightness response is reported as ISO brightness according to ISO 2470-1:2016, and delignification in chemical pulp is tracked by Kappa number according to ISO 302:2004. Operators should cap peracetic acid concentration below 0.2% on oven-dried pulp because higher levels can reduce intrinsic viscosity through cellulose chain scission; published data for softwood kraft pulp under this specific TAED configuration is limited. The terminal product is bleached mechanical or chemical pulp suitable for papermaking grades that require controlled residual peroxide before entering the paper machine; excessive residual peracetic acid must be removed by catalase treatment or extended dilution to avoid interference with cationic retention aids.

    Continuous Textile Bleaching Ranges Demand Rapid TAED Dissolution at Low Bath Ratios

    Continuous knit and woven fabric preparation ranges utilise TAED in peroxide bleaching baths at 1–2 g/L when the target is low-temperature bleaching of cotton and cotton-rich substrates. In a typical pad-batch configuration, the fabric passes through a pad mangle at wet pick-up 80–100%, carrying hydrogen peroxide at 10–20 g/L of 50% active peroxide, caustic soda to pH 11–12, and TAED predispersed in a side tank at 30–40°C with mechanical agitation. The batched roll is stored for 12–16 h at 25–30°C, or steamed for 5–10 min at 100°C in a pad-steam range. Fabric whiteness is evaluated with ISO 11475:2017, and residual peroxide is titrated before dyeing to avoid oxidative destruction of reactive dye chromophores. TAED granules that are not fully dissolved produce localised peracetic acid concentrations on the fabric surface, causing visible white spots; filtration of the pad trough through 100 µm mesh and a minimum liquor ratio of 1:10 reduce this risk. The terminal product is a bleached cotton fabric with a whiteness index suitable for white dyeing or optical brightening, provided the fabric is rinsed below 40°C to prevent alkali-driven strength loss in subsequent tumbling and open-width washing.

    SegmentStandard or regulationMeasured parameter
    LaundryIEC 60456:2010Washing performance and bleach activity on EMPA soiled swatches
    Automatic dishwashingIEC 60436:2015Cleaning performance, soil removal, and programme temperature
    Hard-surface disinfectionEN 1276:2019, EN 1650:2019, EN 13704:2019Bactericidal, yeasticidal/fungicidal, and sporicidal activity
    PulpISO 2470-1:2016, ISO 302:2004ISO brightness and Kappa number
    TextileISO 11475:2017CIE whiteness

    Denture cleanser tablets and alkaline peroxide cleaning sachets require completely dissolving TAED agglomerates in water at 35–45°C to release peracetic acid inside the acrylic surface layer, where oxygen generation and organic stain oxidation coincide. Typical tablet cores contain TAED at 5–10 wt%, sodium percarbonate at 20–40 wt%, citric acid or malic acid at 10–20 wt%, and sodium bicarbonate to produce effervescence; the effervescent disruption of the tablet shortens the dissolution window to 3–5 min, after which the soak time is 15–30 min or overnight for heavy stain deposits. Antimicrobial performance on oral acrylic test coupons can be screened with EN 1276:2019 adapted to denture base materials; published data for TAED-specific denture cleanser formulations under this protocol is limited. Water above 60°C accelerates peracetic acid decomposition and should be avoided; silicone soft liners and metal clasps on removable partial dentures may tolerate only short exposure because the oxidative environment accelerates surface pitting. The terminal product is a soaked, rinsed denture with reduced stain and plaque biofilm, provided the rinse step is completed to remove residual peracetic acid and effervescent salts from the acrylic resin surface.

    Free Quote

    Competitive Tetraacetylethylenediamine prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618963613625 or mail to sales10@ascent-petrochem.com.

    We will respond to you as soon as possible.

    Tel: +8618963613625

    Email: sales10@ascent-petrochem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Tetraacetylethylenediamine (TAED, CAS 10543-57-4; EC 234-123-8) is a crystalline solid bleach activator used with hydrogen peroxide sources such as sodium percarbonate or sodium perborate. The substance, C10H16N2O4, has a molecular weight of 228.25 g/mol and is supplied commercially as uncoated granules, coated granules, fine powder, microgranules, and pigmented speckles. No single global model designation exists; grade selection is controlled by particle size distribution, bulk density, coating type, and purity. In alkaline wash liquor, TAED undergoes base-catalysed perhydrolysis with hydrogen peroxide to generate peracetic acid. The reaction is stoichiometric: 1 mol TAED reacts with 2 mol H2O2 to release 2 mol peracetic acid and 1 mol diacetylethylenediamine. Because peracetic acid is a short-chain peroxycarboxylic acid, bleaching becomes effective at 30–60 °C, whereas unactivated peroxide systems typically require 70–90 °C for comparable stain removal.

    The product is not a bleaching agent by itself; it requires a peroxide source and an alkaline pH. Formulation usage is concentrated in heavy-duty laundry powders, automatic dishwashing tablets, oxygen-based stain removers, and hard-surface soak cleaners. In these applications, TAED is usually post-added to spray-dried or granulated base powders to avoid unnecessary thermal exposure. The typical dosage in laundry powders ranges from 1 wt% to 5 wt%, while automatic dishwashing tablets may contain up to 10 wt% depending on the percarbonate level and soil load.

    What distinguishes tetraacetylethylenediamine from alternative bleach activators?

    TAED differs from sodium nonanoyloxybenzene sulfonate (NOBS) primarily in peracid chain length and hydrolytic behaviour. TAED releases peracetic acid, a C2 peroxyacid that is relatively hydrophilic and diffuses rapidly into tea, coffee, wine, and fruit stains. NOBS releases pernonanoic acid, a C9 peroxyacid with hydrophobic character and greater affinity for sebum and polymerized oil films. On a molar basis, TAED releases 2 mol peracid per mol activator, whereas NOBS releases 1 mol peracid per mol activator. However, the peracid species differ in oxidation potential and soil selectivity, so molar yield alone is not a direct performance comparison.

    Comparisons with manganese or cobalt bleach catalysts are also operational. TAED is a stoichiometric activator that is consumed during perhydrolysis; metal catalysts are catalytic and can remain active after the bleaching sequence. TAED provides controlled peracid generation within the main wash, while uncomplexed metal catalysts may produce dye damage or fibre strength loss if water quality and pH are not tightly controlled. TAED is preferred when a well-defined peracid dose is required and when formulation safety margins are narrow.

    PropertyTetraacetylethylenediamineNOBSUnactivated peroxide
    Generated peracidPeracetic acid (C2H4O3)Pernonanoic acid (C9H18O3)None
    Molar peracid yield2 mol/mol1 mol/mol—
    Soil selectivityHydrophilic stains: tea, coffee, wine, fruitHydrophobic soils: sebum, polymerized oilBroad but temperature-dependent
    Typical activation window30–60 °C20–40 °C70–90 °C
    Peracid water affinityHigherLower—

    When TAED is formulated into automatic dishwashing tablets

    Automatic dishwashing tablet production exposes a dissolution-performance conflict. Tablets must disintegrate within the main wash cycle, typically 10–20 min at 40–55 °C, but must also survive storage and high-speed rotary press compaction. On rotary tablet presses operating between 8 kN and 40 kN compression force, TAED granules with excess fines below 0.1 mm can segregate into the lower hopper fraction, producing tablets with variable TAED content and increased capping or lamination. Conversely, over-densified granules with crushing strengths above 20 N may remain undissolved after the main wash, delaying peracid generation until the rinse.

    The formulation boundary is therefore set by granule size and coating. Commercial TAED granules used in tablets typically have a sieve fraction above 0.2 mm and below 1.0 mm, with fines below 0.2 mm limited to 10% maximum by ISO sieve analysis. A moisture-resistant coating is used to limit premature reaction with percarbonate, but the coating must be soluble or dispersible at the wash pH to avoid particle carry-over. Published data for this specific configuration is limited, but production-scale experience indicates that tablet hardness and TAED dissolution are inversely related; formulation adjustments should be validated by dissolution testing under IEC 60436 conditions or equivalent dishwasher test protocols.

    To avoid premature perhydrolysis during storage, residual moisture in the tablet matrix should remain below 1.0 wt% total formulation water. At relative humidity above 60% RH, pre-drying of TAED or closed-loop dosing is required. Peroxide sources and TAED should be dry-mixed immediately before compression rather than stored as a wetted intermediate.

    Commercial TAED Granule and Powder Specification Ranges

    Commercial TAED is not defined by a universal model code. Suppliers differentiate grades as uncoated granules, coated granules, fine powder, microgranules, and coloured speckles. Fine powder grades typically have bulk densities from 350 g/L to 500 g/L, while granular grades range from 550 g/L to 750 g/L. The selection of a particular commercial grade depends on the density and particle size of the detergent carrier matrix; mismatched bulk density increases segregation during conveying. The following ranges are representative of technical data sheets and certificates of analysis; individual specifications are supplier-specific and may be narrower.

    ParameterTest methodTypical commercial range
    AppearanceVisualWhite to off-white granules or powder
    Assay by HPLCExternal standard≥99.0 area%
    Melting pointCapillary149–153 °C
    Loss on dryingISO 760:1978≤0.5%
    Particle size > 1.0 mmISO 2591-1≤5%
    Particle size < 0.2 mmISO 2591-1≤10%
    Bulk densityISO 697:1981550–750 g/L
    Iron contentICP-OES≤20 mg/kg

    Granule formation commonly occurs in fluidised-bed dryers where an aqueous binder is sprayed onto TAED seed particles; the product temperature is kept below 50 °C to prevent dissolution and uncontrolled agglomeration. Coated grades may add a surface coating that shifts sieve retention upward; the coating level is supplier-specific and is selected to control dust generation and dissolution onset.

    Perhydrolysis kinetics depend on pH, temperature, and peroxide molar ratio

    The rate of peracetic acid release from TAED is influenced by hydrogen peroxide concentration and TAED surface area under alkaline conditions, but the overall process is mass-transfer-limited when granules are large or water temperature is low. The optimum wash-liquor pH is 9.0–11.0. Below pH 8.0, perhydrolysis slows because the perhydroxyl anion concentration is low. Above pH 11.0, peracetic acid decomposition accelerates, reducing bleaching efficiency and increasing oxygen release.

    Temperature exerts two effects. Higher temperature increases the dissolution rate of TAED and the kinetic rate of perhydrolysis. At 20 °C, dissolution is rate-limiting in short-cycle washing machines; at 40–60 °C, peracid generation is sufficiently rapid for main-wash bleaching. This is the basis for using TAED in warm-water laundry cycles that operate below the 70–90 °C range required by unactivated peroxide systems.

    The practical peroxide-to-TAED ratio in detergent formulation is above the stoichiometric 2:1 molar ratio. Excess hydrogen peroxide is required because soils, enzymes, and other formulation components consume peroxide. The exact ratio is formulation-specific and is not fixed by TAED chemistry. When the peroxide source is sodium percarbonate, TAED is dry-mixed separately from the percarbonate where possible to avoid localised moisture and premature perhydrolysis.

    In laundry powder manufacturing, TAED is post-added to the spray-dried base powder after cooling because the base powder leaving the spray dryer may retain temperatures above 50 °C and free moisture above 1%. Post-addition limits premature perhydrolysis with percarbonate and prevents granule plasticisation. Dosing is performed with loss-in-weight feeders; particle size segregation is controlled by matching the bulk density and mean particle size of TAED to the base powder. If the TAED fraction is significantly denser or coarser, vibration during conveying can produce concentration gradients that appear as variable bleach performance in finished packs. Production-scale monitoring typically uses sieve retention and bulk density checks on the final mix, not on TAED alone.

    Storage conditions for TAED are dry, ventilated, and below 30 °C, with relative humidity below 60% RH. Under these conditions, unopened material is typically stable for at least 12 months. Contact with free water, strong acids, concentrated hydrogen peroxide, or hypochlorite stock solutions should be avoided outside controlled dosing because premature perhydrolysis or incompatible oxidiser mixing can generate peracetic acid, acetic acid, or oxygen. TAED is handled as a combustible organic dust; dust extraction and earthing are required where fine powder grades are transferred. The substance is registered under the EU REACH regulation and published ready biodegradability data under the OECD 301 series indicate ready biodegradability. No persistent, bioaccumulative, or toxic classification is assigned under current harmonised data; however, site-specific dust exposure limits and wastewater pH controls apply because peracetic acid decomposition can alter local pH.

    Top