Products

5-Carboxyfluorescein

    • Product Name: 5-Carboxyfluorescein
    • Alias: 5-FAM
    • Einecs: 216-245-5
    • Mininmum Order: 1 g
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: admin@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications

    HS Code

    857353

    Cas Number 76823-03-5
    Molecular Formula C21H12O7
    Molecular Weight 376.32
    Appearance Orange powder
    Purity ≥95% (HPLC)
    Solubility Soluble in DMSO and DMF, slightly soluble in water
    Excitation Maximum 492 nm
    Emission Maximum 517 nm
    Storage Temperature -20°C, protected from light
    Synonyms 5-FAM, 5-Carboxyfluorescein
    Melting Point Approx. 270°C (decomposes)
    Chemical Class Xanthene dye
    Pka Approx. 6.4
    Usage Fluorescent labeling, probe, tracer

    As an accredited 5-Carboxyfluorescein factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 5-Carboxyfluorescein, 1 gram, supplied in an amber glass vial with a screw cap, protected by a sealed outer container.
    Shipping 5-Carboxyfluorescein is shipped at ambient temperature, typically packaged in sealed, light-protective containers to maintain stability and prevent degradation. It should be handled in compliance with relevant chemical safety regulations. Ensure the shipping documentation includes all hazard and handling information as per the material safety data sheet (MSDS) requirements.
    Storage 5-Carboxyfluorescein should be stored in a tightly sealed container, protected from light to prevent degradation. It is best kept at 2-8°C (refrigerated) and in a dry environment, away from moisture and incompatible substances such as strong oxidizing agents. Handle under inert atmosphere if possible, and allow the container to warm to room temperature before opening to prevent condensation.
    Application of 5-Carboxyfluorescein

    Purity 98%: 5-Carboxyfluorescein with purity 98% is used in DNA sequencing assays, where it ensures high signal clarity and low background interference. Molecular Weight 376.3 g/mol: 5-Carboxyfluorescein with molecular weight 376.3 g/mol is used in fluorescence labeling for oligonucleotide probes, where it facilitates precise molecular mass identification. Excitation Wavelength 492 nm: 5-Carboxyfluorescein with excitation wavelength 492 nm is used in flow cytometry experiments, where it delivers strong and stable fluorescent output. Solubility in Water: 5-Carboxyfluorescein with high water solubility is used in cellular uptake studies, where it provides homogeneous dispersion and reproducible fluorescence intensity. Stability Temperature ≤25°C: 5-Carboxyfluorescein with stability at temperatures ≤25°C is used in long-term biochemical storage, where it maintains fluorescence efficiency over extended durations. Particle Size <10 µm: 5-Carboxyfluorescein with particle size less than 10 µm is used in microparticle tracking, where it enhances resolution and detection sensitivity. Melting Point 270°C: 5-Carboxyfluorescein with a melting point of 270°C is used in thermal denaturation studies, where it supports experimental reliability under high temperature conditions.

    Free Quote

    Competitive 5-Carboxyfluorescein prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to admin@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: admin@ascent-chem.com

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    5-Carboxyfluorescein: Supporting Precision in Fluorescence Research

    Practical Insights from Our Production Lines

    In fluorescent labeling, even a subtle tweak in molecular structure can shape the outcome of an entire experiment. Years on the production floor teach us that every detail – from purity checks to packaging choices – carries weight in the reliability of your results. 5-Carboxyfluorescein, often referenced by chemists as 5-FAM, has grown from a specialty label to a staple in laboratories heading into fields ranging from genomics to material science. Our team gets daily questions about batch differences, purity gradients, and performance quirks, since researchers stake quite a bit on consistent data. We learned to treat every lot as more than a product: these are tools for discoveries in real time.

    About 5-Carboxyfluorescein: Our Molecular Perspective

    The compound 5-Carboxyfluorescein, C21H12O7, builds on the xanthene dye family with the carboxyl group attached at the 5-position. That detail turns it into a valuable building block for derivatization, simplifying bioconjugation reactions. In today's synthesis batches, this feature distinguishes 5-FAM from its close relatives, particularly 6-carboxyfluorescein. We've monitored the subtle shift in reactivity firsthand – a placement that can affect everything from labeling efficiency to downstream separation during HPLC runs. This isn't just trivia to a chemist doing oligonucleotide labeling: it spells the difference between sharp, interpretable data and long troubleshooting hours.

    Purity: Why We Chase the Highest Standards

    Fluorescent labeling reagents like 5-FAM demand unwavering purity. In the early days, inconsistencies from even minor byproducts threw off sequence readouts in automated DNA synthesis. Our analytical team spends long hours using HPLC, NMR, and mass spectrometry to chase away traces of starting material and unreacted isomers. We've logged a direct link between product purity and sharper, higher-contrast fluorescence signals, especially in low-abundance target detection. These are not marketing lines – our collaborations with genomics labs have highlighted the downstream impact on detection limits, cost per data point, and, most importantly, accuracy.

    Handling Isomeric Variations: Why Placement Matters

    Ask any synthetic chemist about isomeric purity, and stories surface about failed conjugations or batch-to-batch drift. 5-Carboxyfluorescein and 6-carboxyfluorescein share nearly identical absorbance and emission profiles, but the carboxyl group’s location can cause practical headaches. In solid-phase synthesis, linkage to the 5-position often yields cleaner and more controllable labeling reactions. Over thousands of synthesis cycles, we’ve tracked efficiency differences, especially on complex biopolymers. Our process selectively favors the 5-carboxy isomer, confirmed with analytical controls. End-users typically see fewer side-products in their conjugation cocktails, which leads to less post-synthesis purification and more reliable readouts.

    Technical Details: Direct from the Factory Floor

    From a chemist’s bench perspective, 5-Carboxyfluorescein glows intensely under 494 nm excitation and emits at around 518 nm. This brightness-building core matters in multiplexed assays, where spectral overlap cuts into signal clarity. In practical use, our well-controlled batches repeatedly deliver high extinction coefficients and quantum yields, properties we validate by spectrophotometry and fluorescence standardization. We've weighed out tens of kilos over the years, so deviations in color or crystal habit never get past our QA line. Even routine solubility checks in slightly basic water (pH 8) continue to validate our drying and purification stages.

    Applications Born from Experience

    During synthesis scale-ups, we've supplied 5-FAM for genomics companies and peptide manufacturers, where its free carboxyl group serves as a handy functional handle. In DNA sequencing, each oligonucleotide batch undergoes coupling with activated 5-FAM to yield probes for gene expression or SNP analysis. Manual and automated protocols routinely highlight 5-Carboxyfluorescein's clean coupling profile and robust linker stability. We've had feedback from groups working on real-time PCR, where rapid-cycle settings punish outlier impurities or unstable fluorophores. By keeping our purification standards high, our batches continue to plug straight into instrument workflows without requiring pre-cleanup.

    Our experience extends to flow cytometry and cell-tracking, where intense photostability preserves signal across long acquisition windows. Biologists favor batches with low residual moisture and no detectable byproducts, which prevents photobleaching and non-specific background. Because we’ve managed both gram-scale academic orders and industrial-scale multi-kilo campaigns, our technologists tweak drying methods and packaging atmospheres to keep each shipment reliable and storage-stable. This isn’t routine: it’s the difference between a robust, day-long experiment and scrambling to recalibrate detectors in mid-run.

    Choosing Among Fluorescein Variants: What Production Taught Us

    People new to fluorescent labeling often ask about differences among 5(6)-Carboxyfluorescein, carboxyfluorescein mixtures, or N-hydroxysuccinimide (NHS) activated versions. The biggest learning from production is that pure 5-carboxy isomers give more predictable, site-specific reactions during coupling. Mixtures of 5- and 6- variants sometimes introduce background during capillary electrophoresis or produce unwanted peaks during MALDI-TOF.

    Regarding the NHS esters, we figured out years ago that freshly prepared batches outperform shelf-aged products, so we limit inventory age and ship under moisture-blocking packaging. Our best results come from tightly controlling the conversion process and doing QA on each batch rather than relying on supplier data sheets. For teams requiring faster coupling onto small-molecule drugs or peptides, NHS-activated 5-FAM simplifies protocol steps, saving time but with the caveat that reactivity drops with exposure to ambient humidity. We solve this with small-unit packing and rapid order fulfillment directly from our manufacturing line.

    Why Model and Specifications Matter in Everyday Lab Work

    Every model of 5-Carboxyfluorescein defined in our plant draws on decades of process tweaks. We review melting points, water content, and impurity levels as part of every batch release. Some of the toughest customer calls we’ve handled focus not just on the >98% HPLC purity, but on minuscule lot-to-lot yield swings that reveal tweaks in drying schedules or extractants. Our technical teams provide certificates based on spectroscopic data, not generic statements. It’s a daily reality: posting live trace documentation and chromatograms helps researchers match reagent performance with their experimental design, cutting the uncertainty from repeated syntheses or scale-up.

    Specifications aren’t just a compliance checkbox; they're targets met through hands-on tuning of pH, solvent concentration, and temperature profiles. To keep photobleaching at bay, we avoid UV-exposure during all final product handling, only opening up batches for last-step bottling in low-light rooms. Our commitment to transparency reaches into raw material sourcing, which directly impacts total impurities detected at scale. This level of transparency builds trust and keeps feedback cycles between manufacturers and end-users sharp.

    Safety, Stability, and Everyday Lab Realities

    Anyone who’s handled fluoresceins for a decade or more knows how rapidly they pick up moisture and degrade under the wrong storage. We issue plain-language storage guidelines based on actual stability tests, not just theory. Typical lots, protected from light and sealed with desiccant, hold their analytical properties for upwards of two years. Users who stick to sub-ambient storage for standards see consistent strength in absorption and emission spectra. We know that accidental repeated warm-up and reseal cycles do crop up in busy labs: our quality controls, tested by deliberate abuse, help guard final user results against common handling missteps.

    On safety, 5-Carboxyfluorescein ranks among the less hazardous in our inventory, but any fine powder deserves respect. Even measurable inhalation exposure from spills isn’t common in our shop due to tight dust management and open-air controls, and we share these practices openly. We don’t claim the reagent is completely benign, but with ordinary PPE, our own teams have never recorded chronic sensitivity or acute toxicity incidents from regular handling. It’s this mixture of risk management and careful, repeated process auditing that industry partners expect from us.

    Our Challenges and Continuous Problem-Solving

    One of the persistent asks in larger orders comes from customers pushing purity or isomeric selectivity beyond what commercial suppliers target. Meeting those requests, especially in multi-kilogram volumes, calls for vigilant batch tracking and equipment calibration. We learned to keep logs that track every kilogram back to individual crystal fractions. Equipment errors as minor as column loading rates or solvent system drift can tip the isomeric ratio. Our approach pairs automated chromatography with regular human spot checking, because we’ve seen how even small technical lapses ripple through downstream research.

    Shipping to extreme climates or countries with volatile logistics brings another set of obstacles. We ran into issues early on with fluorescence loss during airfreight to equatorial regions. Modification in packaging and tighter inventory controls now maintain fluorescence performance for even our longest-haul customers. Every time we solve a logistics or purity issue, we toss the lesson back into our process review cycles, treating troubleshooting as routine.

    Serving Scientists: Day-to-Day Interactions Over Hype

    Scientists and technicians contact us directly, not through brokers or resellers. This direct channel lets us collect immediate feedback from the field. We hear specifics about minor fogging in cuvettes, odd baseline drift in spectrophotometers, or rare precipitation behavior in non-standard buffers. Our technical staff answers with answers grounded in years of real-world adjustments to milling, drying, and crystalline formulation. Every plant manager, analyst, and shipping tech in our factory gets regular updates on the quirks and needs users report. These aren’t just “customer service” responses; they push us to rethink packaging, mixing, and QC for each next lot.

    We keep options for customization open precisely because researchers point out gaps in mainstream supply – higher purity needs, unique solvent formulations, or different vial sizes. It’s common for academic or startup groups to request small custom syntheses, expecting open communication on every step. We maintain dialogue as the research unfolds, supporting both immediate use and long-term projects. This ongoing contact guides how our team tweaks the manufacturing pipeline for the next round of production.

    Looking Forward: Building Solutions from the Factory Up

    As new assays push for lower detection thresholds and more robust multi-color workflows, the demand for pure, predictable 5-Carboxyfluorescein continues to rise. We see requests not just for higher brightness, but for consistent performance down to the last milligram in large-scale automation. Our hands-on experience tells us that small changes in synthesis or packaging ripple downstream in ways formal literature sometimes misses. By keeping the entire process in-house – from raw material selection to post-sale support – we hold onto control points that really matter to bench scientists.

    Quality control is never a one-time fix; it’s routine revision. As laboratories move toward more automated high-throughput systems, reliable labeling reagents don’t just save money – they make new types of experiments possible. By constantly listening to feedback and responding with hands-on improvements, we make our contribution to science practical and immediate. After years of watching the field change, it’s clear that the simple things – clear communication, uncompromising batch records, attention to customer needs – drive better results across every research context that depends on bright, reliable 5-Carboxyfluorescein.

    Top