| HS Code | 508149 |
| Productname | High Purity MTBE HPLC & Electronic Grades |
| Grade | HPLC & Electronic Grades |
| Chemicalname | Methyl tert-butyl ether |
| Synonyms | MTBE; tert-Butyl methyl ether; 2-Methoxy-2-methylpropane |
| Casnumber | 1634-04-4 |
| Ecnumber | 216-653-1 |
| Molecularformula | C5H12O |
| Molecularweight | 88.15 g/mol |
| Appearance | Clear colorless liquid |
| Odor | Ether-like |
| Purity | ≥99.9% |
| Density | 0.7405 g/cm³ at 20 °C |
| Boilingpoint | 55.2 °C |
| Meltingpoint | -109 °C |
| Flashpoint | -10 °C (closed cup) |
| Autoignitiontemperature | 374 °C |
| Explosivelimits | 1.5–8.5% (v/v) in air |
| Refractiveindex | 1.369 at 20 °C |
| Viscosity | 0.36 mPa·s at 20 °C |
| Vaporpressure | 27 kPa at 20 °C |
| Watersolubility | 42 g/L at 20 °C |
| Logp | 0.94 |
| Watercontent | ≤0.03% (HPLC grade); ≤0.005% (electronic grade) |
| Nonvolatilematter | ≤5 ppm (HPLC grade); ≤1 ppm (electronic grade) |
| Uvabsorbance | ≤0.01 AU at 254 nm |
| Metals | ≤10 ppb (electronic grade) |
| Particles | ≤100 particles/mL >0.5 µm (electronic grade) |
As an accredited High Purity MTBE HPLC & Electronic Grades factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Supplied in 1 L amber glass bottles or 200 L stainless-steel drums, nitrogen-sealed for HPLC and electronic-grade MTBE. |
| Container Loading (20′ FCL) | 20′ FCL: 80 × 200 L drums; 16,000 L High Purity MTBE HPLC & Electronic Grades; Class 3 flammable liquid. |
| Shipping | High Purity MTBE (HPLC & Electronic Grades) ships as UN2398, Methyl tert-butyl ether, Class 3 flammable liquid, Packing Group II. Use approved steel drums or ISO tanks, hazmat labels/placards, and licensed carriers. Keep cool, dry, away from ignition sources and oxidizers. Comply with DOT, IATA, IMDG, and SDS requirements. |
| Storage | Store High Purity MTBE HPLC & Electronic Grades in a cool, dry, well-ventilated flammable-liquids cabinet, away from heat, sparks, flames, oxidizers, and direct sunlight. Keep containers tightly closed, properly labeled, and electrically grounded. Use inert blanketing where feasible; avoid prolonged storage, inspect for peroxides, and follow SDS/local regulations. Protect from static discharge and incompatible materials. Maintain adequate ventilation and emergency spill equipment. |
| Shelf Life | High Purity MTBE HPLC & Electronic Grades: typical shelf life 24 months when stored unopened, cool, dark, away from ignition sources. |
For normal-phase liquid chromatography of free fatty acids, monoglycerides, diglycerides, and polyethylene glycol derivatives on unmodified silica, methyl tert-butyl ether is employed as a polar-aprotic modifier rather than as a bulk mobile phase. The typical isocratic blend consists of n-hexane, methyl tert-butyl ether, and 2-propanol in volumetric ranges from 80:20:2 to 95:5:0.5, adjusted according to the column batch and the acid number of the sample extract. Mobile phase preparation is conducted in borosilicate reservoirs fitted with 0.1 µm polytetrafluoroethylene inlet filters, and the blend is degassed under vacuum followed by helium sparging at 15 mL/min to prevent detector drift when the UV absorbance is monitored at 210 nm. The solvent viscosity of approximately 0.35 mPa·s at 20°C is lower than that of isopropanol-containing mixtures, which reduces backpressure on a 250 mm × 4.6 mm silica column at 2.0 mm/s linear velocity to between 90 bar and 140 bar on standard binary pumps. Detector baseline stability over a 30-minute drift test is considered acceptable only if the photometric noise does not exceed 5 × 10−5 AU; this criterion is applied after the column has been equilibrated for 10 column volumes. High-purity MTBE for HPLC is specified with a GC assay of at least 99.9% by ASTM D5441, a water content not exceeding 0.02% by ASTM D1364, and a non-volatile residue below 5 mg/L by ASTM D1353. These limits are representative commercial certificate-of-analysis values and should be verified against the vendor lot before use because published data for this specific configuration are limited.
Column wash cycles after use of high-purity MTBE in normal-phase methods are configured to avoid residual silanol-bound water from the sample extract. A gradient reverse wash with methyl tert-butyl ether at 1.0 mL/min for 20 minutes followed by n-hexane at 0.5 mL/min for 10 minutes is applied before the column is stored in n-hexane/MTBE 95:5 by volume to minimize peroxide accumulation in the eluent. Peroxide concentration in the stored column eluent is checked monthly with a test strip calibrated at 0.5 mg/kg, and columns that have been exposed to peroxide levels above 1.0 mg/kg are regenerated with an isopropanol wash to prevent irreversible binding of oxidation products to the silica surface. The use of MTBE as a sample diluent has a narrow operational window for analytes that are sensitive to trace peroxides; samples containing oxidation-labile compounds such as vitamin A palmitate or conjugated linoleic acid should be supplemented with 10 mg/L butylated hydroxytoluene or an equivalent radical scavenger only after the scavenger is shown to be chromatographically silent under the same gradient conditions. The low water tolerance of unmodified silica columns means that a solvent lot near the 0.02% water limit can require predrying with activated 3A molecular sieves or a silica-based solvent drying column before use in acid-sensitive separations. Fluoroelastomer seals and PEEK check valves are preferred because MTBE slowly extracts phthalate plasticizers from flexible polyvinyl chloride tubing, producing extraneous peaks at 220 nm and 254 nm that are absent from control injections. When MTBE is used as a sample diluent for non-aqueous reversed-phase methods, the injection volume should not exceed 10 µL per 100 µL loop because the high vapor pressure of 27.8 kPa at 20°C can cause needle-seat outgassing with autosamplers operating above 25°C ambient temperature.
| Parameter | HPLC grade limit | Electronic grade limit | Test method |
|---|---|---|---|
| Assay | ≥ 99.9% | ≥ 99.95% | ASTM D5441 |
| Water | ≤ 0.02 wt% | ≤ 0.005 wt% | ASTM D1364 |
| Non-volatile residue | ≤ 5 mg/L | ≤ 2 mg/L | ASTM D1353 |
| Total trace metals | ≤ 1 mg/L | ≤ 50 µg/L | ICP-MS after evaporation |
| Peroxide as H₂O₂ | ≤ 0.5 mg/kg | ≤ 0.2 mg/kg | supplier peroxide test |
Electronic-grade MTBE is selected for quartz oscillator cleaning and carrier-solvent applications not because of bulk solvency but because the post-evaporation ionic burden is low enough to prevent frequency shifts after wire bonding. Supplier certificates of analysis for electronic-grade lots typically list sodium, potassium, iron, nickel, chromium, copper, and zinc at or below 10 µg/kg per analyte, and total non-volatile residue below 2 mg/L by ASTM D1353. The solvent is dispensed through 0.2 µm PTFE capsule filters in an ISO Class 5 cleanroom, and the final rinse is performed in a nitrogen atmosphere with a dew point below −40°C. Compatibility with stainless steel, quartz, borosilicate glass, and PTFE is documented, while extended contact with aluminum and unlined mild steel is avoided because trace water and atmospheric oxygen can generate corrosive ether hydroperoxides at the metal surface. Because MTBE is a peroxide-forming ether, electronic-grade material is packaged in amber glass under nitrogen and opened containers are assigned a 90-day retest interval; peroxide concentration is maintained below 0.2 mg/kg by periodic passage through activated alumina columns that are validated to release no aluminum fines above the particle specification. The evaporation rate in an open bath is governed by the vapor pressure of 27.8 kPa at 20°C, which requires local exhaust ventilation with a face velocity of at least 0.5 m/s and a flash point control based on the tag closed-cup value of −28°C. Particle counts in as-received electronic-grade MTBE are monitored by light obscuration with channels at 0.2 µm and 0.5 µm; a typical specification is no more than 25 particles/mL at 0.2 µm and no more than 5 particles/mL at 0.5 µm. For high-precision metal parts where ionic contamination above 10 µg/L is unacceptable after drying, the final rinse is conducted with two successive 5 mL aliquots of fresh solvent rather than a single 10 mL rinse; this step reduces the cation carryover by dilution and is specified in the cleaning protocol after plasma ashing of resist residues. Electronic-grade MTBE is not a universal electronic solvent; its use in wafer cleaning must be qualified against the specific photoresist or bonding material because the ether can extract low-molecular-weight oligomers and deposit them as organic haze on active surfaces. Published data for this specific configuration are limited, and each cleaning line is qualified by evaporating 500 mL of solvent and analyzing the residue pattern by ion chromatography and total organic carbon before release.
In high-throughput lipidomics, methyl tert-butyl ether has replaced chloroform in a two-phase extraction protocol because the organic phase floats above the aqueous-methanolic phase, allowing automated liquid handling without puncturing a lower chloroform layer. The published method uses 200 µL of biological fluid, 1.5 mL of methanol, 5 mL of high-purity MTBE, and 1.25 mL of ultrapure water, followed by shaking at 1,000 rpm for 10 minutes and centrifugation at 10,000 × g for 5 minutes at 4°C. Acidic phospholipids including phosphatidic acid and phosphatidylinositol are recovered primarily in the upper MTBE-rich layer; published recovery data for this specific configuration are limited, and individual laboratories validate recovery against internal deuterated standards in each 96-well batch. The requirement for high-purity MTBE in this workflow arises from the electrospray ionization source, where phthalate esters, fatty acid residues, or non-volatile plasticizers from technical-grade solvent produce background ions that suppress phosphatidylcholine detection below 100 ng/mL on quadrupole-time-of-flight instruments. Solvent blanks are evaporated from 50 mL lots and examined by LC-MS before a certificate of analysis is accepted; any phthalate signal above the method detection limit triggers rejection of that solvent lot for extraction use.
Automated liquid handlers are configured with conductive polypropylene tips and a 10 mL syringe adapter, and because the density of MTBE is 0.740 g/mL at 20°C by ASTM D4052, the phase inversion after water addition is confirmed by visual inspection before upper-layer aspiration. The high vapor pressure of 27.8 kPa at 20°C means that open reservoirs lose volume by evaporation during long batch runs; reservoirs are capped and cooled to 10°C to keep evaporation below 2% per hour. In addition, the water in the solvent is limited to 0.02% by ASTM D1364 because excess water shifts the partition coefficient of lysophosphatidic acid toward the lower phase and alters relative quantitation when an internal standard is not used. Validation of lot-to-lot reproducibility in a multi-batch extraction campaign uses a pooled plasma control sample and a stable isotope-labeled internal standard mixture containing phosphatidylcholine d7 and sphingomyelin d31; the relative standard deviation of the extraction alone should be less than 15% in the absence of derivatization. If the relative standard deviation exceeds 20%, the phase boundary is re-checked and the centrifuge temperature is lowered to 4°C. The MTBE layer is diluted 1:1 with methanol containing 5 mM ammonium acetate before direct infusion for shotgun lipidomics. This extraction approach is unsuitable for matrices containing high concentrations of phospholipases unless the enzyme activity is quenched before MTBE addition, and its use for bile acid profiling requires a separate acidified extraction because the neutral pH of the MTBE-methanol-water system does not fully protonate taurine-conjugated bile acids.
When a solvent must remain aprotic under reflux for 48 hours during a lithium diisopropylamide-mediated enolate formation, methyl tert-butyl ether is selected over tetrahydrofuran because its dielectric constant of 2.6 at 25°C reduces side reactions that arise from charge separation of the enolate. The solvent is pre-dried over activated 3A molecular sieves for 72 hours until the water content measured by ASTM D1364 is below 10 mg/kg, then transferred under argon through a stainless-steel cannula into a jacketed glass reactor with a PTFE-coated thermowell. Reaction temperature is maintained at −20°C to +5°C for enolate formation and then raised to 35°C for the coupling step; heat removal from the exotherm is controlled by a circulating bath with a temperature stability of ±0.5°C over a 12-hour ramp. Because MTBE forms peroxides slowly under ambient light, the equipment train includes an in-line UV-blocking recirculation filter, and the distillation receiver is monitored with peroxide test strips calibrated at 0.5 mg/kg before solvent reuse. Batch records from pilot-plant campaigns show that residual water above 50 mg/kg causes hydrolysis of silyl-protected intermediates and reduces the isolated yield of a model steroid alkyne by up to 15 percentage points; that figure is specific to one campaign and is not a universal yield coefficient.
Methylmagnesium bromide additions are carried out in MTBE at concentrations up to 1.0 M, with the addition rate controlled so that the internal temperature does not exceed 40°C, because the boiling point of 55.2°C provides a stable reflux under atmospheric pressure and allows solvent recovery at the end of the reaction. Solvent recovery from an aqueous quench is accomplished by redistillation at 55.2°C; the recovered distillate is re-certified for water and peroxide content before reuse because peroxides may accumulate in the still bottoms and create a thermal hazard above 10 mg/kg. For continuous-flow synthesis, MTBE is delivered by a titanium or PTFE diaphragm pump with a maximum stroke frequency of 80 rpm; the pump head is vented to a chilled condenser because the vapor pressure at the feed temperature of 30°C can cause cavitation at low suction pressure. The flash point of −28°C requires the feed vessel to be grounded and blanketed with nitrogen; the oxygen concentration in the headspace is managed below 5% by volume before the pump is started. This configuration is used for lithiation reactions because it avoids the cyclic ether autoxidation products that complicate downstream workup. This application does not tolerate the use of butylated hydroxytoluene-inhibited technical-grade MTBE because the inhibitor becomes a non-volatile residue in the final chromatographic purification step and can co-elute with the target product on silica gel using a hexane-ethyl acetate gradient. Published data for this specific configuration are limited, and each plant batch is released only after a water value below 10 mg/kg, a peroxide value below 0.5 mg/kg, and a GC purity above 99.9% by ASTM D5441 are documented.
For the dissolution of low-molecular-weight polyisobutylene and butyl rubber prior to size-exclusion chromatography, MTBE with water below 0.02% is used as a viscosity-reducing diluent that suppresses aggregate formation occurring in pure tetrahydrofuran. The sample is dissolved at 40°C for 2 hours in a crimped glass vial with a PTFE-lined cap, at a concentration of 1.0 mg/mL, and filtered through a 0.45 µm polytetrafluoroethylene syringe filter before injection into a 7.8 mm × 300 mm styrene-divinylbenzene column set maintained at 35°C. The mobile phase is delivered at 1.0 mL/min against a backpressure of 55 bar to 70 bar, and the differential refractive index detector baseline drift is evaluated over 60 minutes after the solvent has been sparged with helium. Calibration with narrow-dispersity polystyrene standards is performed in the same solvent matrix, and the Mark-Houwink parameters for the specific elastomer are taken from the column manufacturer's technical bulletin rather than from low-molecular-weight polystyrene equivalents. This procedure is not suitable for high-molecular-weight polyolefins that require trichlorobenzene at 145°C, and its use for graft copolymers requires a solubility test before injection. Solvent lots for this application are rejected if ultraviolet absorbance at 230 nm exceeds 0.1 AU or if particulate counts above 10 µm exceed 100 particles/mL in the as-received bottle, because such contamination shortens the lifetime of the inline guard column and distorts the low-molecular-weight tail of the distribution. The high volatility of MTBE relative to tetrahydrofuran reduces the time required for fraction collection and subsequent solvent evaporation under a nitrogen stream at 35°C; however, recovery of high-boiling fractions requires a rotary evaporator with a vacuum controller set to 150 mbar to prevent sample loss due to entrainment.
Competitive High Purity MTBE HPLC & Electronic Grades prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
For chromatographic and electronic wet-processing requirements, High Purity MTBE HPLC & Electronic Grades are two solvent release formats of methyl tert-butyl ether (CAS 1634-04-4) with GC assay levels of ≥99.9% and ≥99.95%, respectively. The manufacturing pathway is catalytic etherification of isobutylene with methanol over an acidic ion-exchange resin, followed by extractive methanol removal, water washing, azeotropic distillation, and low-water finishing through dried molecular sieves. The product is not a fuel oxygenate. It differs from fuel-grade MTBE by controlled removal of methanol, C4 olefin oligomers, organic sulfur compounds, and by the absence of gasoline antioxidant packages. The HPLC grade is controlled primarily for UV transparency, water content, and nonvolatile residue; the electronic grade adds limits for sodium, potassium, iron, zinc, chloride, sulfate, and submicron particles. At the point of fill, the electronic grade passes through a 0.05 μm PTFE membrane and is packaged under nitrogen in fluoropolymer-lined containers. HPLC-grade material is filled into amber borosilicate glass with nitrogen-blanketed headspace. Exact lot values are reported on the certificate of analysis.
In refinery blending, fuel-grade MTBE is released for service where octane contribution, vapor pressure, and distillation range are relevant; it may contain dissolved C4 hydrocarbons, unreacted methanol, acidic catalyst residues, and higher concentrations of polar impurities. These species do not affect fuel combustion but create baseline drift in HPLC and leave ionic residues in electronic surface preparation. The HPLC grade reduces methanol to ≤0.01%, water to ≤100 ppm by ASTM E203-16 Karl Fischer titration, and residue after evaporation to ≤2 ppm. The electronic grade tightens the same parameters to ≤50 ppm water and ≤1 ppm residue while adding limits of ≤10 ppb for sodium, ≤10 ppb for potassium, ≤5 ppb for iron, and ≤5 particles/mL for particles ≥0.2 μm measured with an optical particle counter calibrated to ISO 21501-1. These values are representative of current industrial producer bulletins; the governing certificate of analysis for each lot controls final acceptance.
Differences from other ether solvents are defined by peroxide formation rate, boiling point, and UV cutoff. MTBE has a UV cutoff near 210 nm, which is lower than tetrahydrofuran for many detector systems; its viscosity at 20°C is 0.34 mPa·s, which is substantially lower than the 0.48 mPa·s typical of tetrahydrofuran. These properties reduce column backpressure but do not eliminate method validation. A separation developed in tetrahydrofuran or diethyl ether cannot be transferred to MTBE without adjustment of solvent strength and re-equilibration because the eluotropic strength and hydrogen-bonding contribution are not equivalent.
As a low-viscosity modifier with low hydrogen-bonding character, HPLC-grade MTBE is introduced into normal-phase and chiral mobile phases. In a standard 4.6 mm internal-diameter column packed with 5 μm silica, the addition of 10% v/v MTBE to n-hexane reduces the viscosity of the mobile phase and changes retention of polar analytes without introducing the high UV-absorbing background of ethyl acetate. Because the solvent is released at ≤100 ppm water, it functions as a dry normal-phase component; however, silica columns take up water rapidly in humid laboratories. Once a bottle is opened, the mobile phase reservoir should be blanketed and the solvent line fitted with a 3A molecular sieve trap to prevent ambient moisture from raising the water content above 200 ppm. Above this level, retention time reproducibility for polar analytes deteriorates because water adsorbs to silanol sites and changes column activity.
For reversed-phase methods, MTBE is not a drop-in substitute for acetonitrile or methanol. Its aqueous solubility is limited, and phase separation is the primary failure mode when water is added to a non-polar MTBE mobile phase. If water is required as a co-modifier, sufficient acetonitrile or methanol must be added to maintain a single phase. Published data for the exact cloud-point curves of MTBE/water/acetonitrile in all proportions is limited; laboratories should determine the miscibility boundary experimentally on a benchtop titration apparatus before committing a gradient method to routine use. Column equilibration with MTBE-containing normal-phase mobile phases requires at least 20 column volumes for retention time repeatability; columns with high-surface-area polar embedded phases may require up to 40 column volumes before stable baselines are obtained.
When laboratory relative humidity exceeds 60%, daily viscosity and water checks are advised because water uptake and solvent evaporation change the effective mobile phase composition. The low boiling point of 55.2°C allows post-column recovery by rotary evaporation at bath temperatures below 40°C, but the same volatility increases evaporation from the mobile phase reservoir. Autosampler needle washing with MTBE should be followed by a brief methanol wash to prevent slow evaporative residue build-up on the injection needle. In high-sensitivity UV detection at 210 nm, the detector lamp is operated at a bandwidth no wider than 8 nm to minimize the contribution of solvent absorbance; acetonitrile remains the lower-background solvent if method sensitivity is detector-limited.
In downstream formulation and precision cleaning, electronic-grade MTBE is released for applications where ionic contamination and particle loading are controlled at the point of use. The material is handled in stainless steel or fluoropolymer-lined equipment with point-of-use filtration; 0.05 μm capsule filters or particle-rated cartridges are installed at the dispense point. Trace metals are quantified by ICP-MS after evaporation of a known solvent volume. Sodium and potassium are the most common mobile ions and are controlled at single-digit ppb levels in electronic-grade product. Chloride and sulfate are limited because salt residues can promote electrochemical corrosion and increase dielectric leakage. The release specification includes a maximum particle count for particles ≥0.2 μm, corresponding to the critical defect size in many wet-processing operations. However, published data for MTBE-specific particle shedding from fluoropolymer-lined drums over 24-month storage is limited; recertification at 12-month intervals is therefore used for electronic-grade stock.
During production-scale blending, stainless steel transfer lines with incomplete passivation can raise iron above 5 ppb even when the source solvent is within specification. For this reason, high-purity MTBE should be dispensed through electropolished stainless steel or fluoropolymer tubing that has been flushed with 5 to 10 line volumes before sampling. Metal extractables are not removed by the point-of-use membrane filter; only the particle burden is reduced. The product is not intended for use in wafer cleaning processes where a fully aqueous or strongly oxidizing chemistry is required. MTBE is a highly flammable organic solvent and must be kept out of oxidizer lines. When MTBE is used for organic residue removal, the rinse step must be followed by a polar solvent such as isopropanol or acetone to wet the surface and displace dissolved residue before aqueous rinsing. Process qualification should include corrosion coupons, metal-oxide semiconductor test wafers, and surface defect scans using a darkfield inspection system. No statement of cleaning efficiency can be made without measuring the actual residue type and surface energy; published data for this specific configuration is limited.
| Parameter | HPLC grade | Electronic grade | Method |
|---|---|---|---|
| Assay by GC | ≥99.9% | ≥99.95% | gas chromatography with FID |
| Methanol | ≤0.01% | ≤0.005% | gas chromatography with FID |
| Water | ≤100 ppm | ≤50 ppm | ASTM E203-16 |
| Residue after evaporation | ≤2 ppm | ≤1 ppm | gravimetric evaporation, internal method |
| UV absorbance at 210 nm | ≤0.5 AU | ≤0.2 AU | UV-Vis, 1 cm path length |
| Peroxide as active oxygen | ≤1 ppm | ≤1 ppm | iodometric titration |
| Sodium + potassium | not specified | ≤10 ppb | ICP-MS |
| Iron | not specified | ≤5 ppb | ICP-MS |
| Chloride | not specified | ≤20 ppb | ion chromatography |
| Sulfate | not specified | ≤20 ppb | ion chromatography |
| Particles ≥0.2 μm | ≤25/mL | ≤5/mL | ISO 21501-1 optical particle counter |
Under EC 1272/2008, MTBE is classified as a highly flammable liquid with a flash point of -28°C and a boiling point of 55.2°C. Bulk storage must be nitrogen-blanketed and grounded; transfer equipment must be constructed of stainless steel or fluoropolymer-lined carbon steel. Copper and zinc-containing fittings are not recommended because transition metals can promote peroxide formation and contaminate the solvent. Elastomer seals in pumps and valves must be selected for ether service; nitrile and EPDM swell in MTBE, so FFKM or PTFE gaskets are required. The solvent forms peroxides at a lower rate than diethyl ether, but the rate is not zero. Opened containers should be kept tightly sealed, stored in a flammable cabinet below 25°C, and protected from light. Use of the material in a distillation to dryness is prohibited: peroxides can concentrate in the still bottoms and create an explosion hazard.
Because BHT or similar stabilizers introduce a nonvolatile residue and can interfere with UV detection at 210 nm, the product is supplied without added phenolic inhibitors. Consequently, the user must manage peroxide formation by inventory control and inert gas blanketing. For HPLC laboratories, a bottle of HPLC-grade MTBE should be assigned a maximum open-life of 3 months and should be checked with peroxide test strips if held beyond that period. The lower flammability limit of 1.6% v/v and the upper flammability limit of 8.4% v/v in air require local exhaust ventilation and vapor monitoring during bulk decanting. Personnel must avoid breathing vapor and use spark-proof equipment. The headspace of an opened bottle should be displaced with dry nitrogen after each use; compressed air is not acceptable because it introduces oxygen and moisture.
When transferring a method from other ether solvents to MTBE, the comparison of physical properties is required rather than direct substitution. The table below lists the common parameters used to adjust gradient elution and extraction methods. MTBE is more volatile than tetrahydrofuran, has a lower flash point, and is less water miscible than tetrahydrofuran. These differences favor MTBE for extraction processes that require an organic phase separation from water, but they reduce the maximum water content allowable in reversed-phase mobile phases. The lower viscosity of MTBE relative to tetrahydrofuran reduces column backpressure at constant flow, but the shorter volatility window requires daily solvent replacement to avoid composition drift.
| Property | MTBE | Tetrahydrofuran | Diethyl ether |
|---|---|---|---|
| Boiling point | 55.2°C | 66°C | 34.6°C |
| Density at 20°C | 0.7405 g/mL | 0.889 g/mL | 0.713 g/mL |
| Viscosity at 20°C | 0.34 mPa·s | 0.48 mPa·s | 0.23 mPa·s |
| Flash point | -28°C | -20°C | -40°C |
| UV cutoff | 210 nm | 212 nm | 218 nm |
| Water miscibility | partial | miscible | partial |
For critical analytical and electronic cleaning operations, the user should confirm the lot-specific certificate of analysis against the application limit. The product is not supplied as a sterile or pyrogen-tested material, and particulate limits apply to particles ≥0.2 μm only; smaller particle populations are not routinely quantified unless the electronic grade is ordered with a specific ultrafine particle package. Published data for long-term stability beyond 12 months in intact containers is limited; retained samples are therefore retested at the 12-month interval rather than assigned an open-ended shelf life. The material should not be blended with strong oxidizers, concentrated peroxides, or reactive metals. Where sodium or potassium contamination must remain below 1 ppb, point-of-use repurification and cleanroom decanting are required, because release limits alone cannot guarantee cleanliness after container opening.